{"product_id":"bently-nevada-330877-080-37-00-3300-xl-50mm-extension-cable","title":"Bently Nevada 330877-080-37-00 3300 XL 50mm Extension Cable","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330877-080-37-00\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330877\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3300 XL extension cable, operates as a dedicated hardware component for connecting 3300 XL 50 mm proximity probes to the associated Proximitor sensors within vibration monitoring instrumentation platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix \u0026amp; Configuration Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 330877-080-37-00 part number denotes a specific length and shielding configuration designed for the 50 mm probe series. The suffix codes indicate an 8.0 meter cable length with armor and a specific connector interface required for high-reliability TSI (Turbomachinery Supervisory Instrumentation) installations. This cable maintains the rigid impedance requirements necessary for the 50 mm transducer system to function within its linear range.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330877-080-37-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.95 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 cm x 25 cm x 10 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (None)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 50 mm Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.0 meters\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eArmor Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTransducer Signal Integrity \u0026amp; Impedance\u003c\/h3\u003e\n\u003cp\u003eThe 50 mm transducer system relies on extremely stable signal transmission to measure low-frequency vibrations or large-gap position movements accurately. The 330877 extension cable is engineered with internal coaxial shielding to minimize electromagnetic interference (EMI) and cross-talk. To ensure the performance metrics of the 3300 XL system, the total length (probe + extension cable) must match the calibration of the Proximitor. The use of stainless steel armor provides protection against physical abrasion in high-density machinery housing environments.\u003c\/p\u003e\n\u003ch3\u003eShipment Contents\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1x 330877-080-37-00 Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1x Connector protector kit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1x Installation technical manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCable Protection: Use the integrated stainless steel armor to shield the cable from localized mechanical impact and chemical exposure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBend Radius: Maintain a minimum bend radius of 64 mm for armored cables to prevent damage to the internal coaxial core and shielding.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnection Security: Ensure ClickLoc connectors are fully mated and secured. Use only light torque with pliers to lock connectors; over-tightening can cause pin misalignment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: The cable shield must remain isolated from the machine case and mounting hardware to prevent ground loop noise that can introduce false vibration readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIs this cable compatible with standard 8 mm probes? No, the 330877 series is uniquely calibrated for the electrical characteristics of the 3300 XL 50 mm probe system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I repair a damaged armored cable? No, damage to the coaxial core or internal shielding renders the cable unsuitable for critical monitoring; the assembly must be replaced.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the impact of cable length variation? The system is factory-calibrated for specific lengths; adding or removing length alters the impedance and invalidates the output sensitivity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I pull the cable through a conduit using the connector? Yes, provided the connector protectors are installed and pulling force is kept below 275 N (62 lb).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat material is the armor made of? The armor is stainless steel, which provides both physical protection and excellent resistance to corrosive industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre these cables used in hazardous areas? Yes, when installed according to the Bently Nevada control drawings for intrinsically safe (Ex i) systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDo I need a specific tool to connect the cable? No, the ClickLoc interface is designed for manual connection; verify secure seating by feel and visual inspection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the cable be exposed to oil? Yes, the cable jacket and armor are designed for immersion in standard industrial lubricating oils and hydraulic fluids.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518836990125,"sku":"330877-080-37-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330877-080-37-00-3300-xl-50mm-extention-cables-jcpqgxp1rjv.jpg?v=1766980069","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-330877-080-37-00-3300-xl-50mm-extension-cable","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}