{"product_id":"bently-nevada-330854-080-25-05-3300-xl-25mm-extension-cable","title":"Bently Nevada 330854-080-25-05 3300 XL 25mm Extension Cable","description":"\u003ch2\u003eHigh-Fidelity Signal Integrity\u003c\/h2\u003e\n\u003cp\u003eThe Bently Nevada 330854-080-25-05 extension cable serves as the critical high-impedance link within the 3300 XL 25mm Proximity Transducer System. Specifically designed for large-scale rotating machinery, this cable maintains the electrical length required to ensure precise displacement and axial position data transmission between the 25mm probe and the Proximitor sensor. In heavy-duty environments like steam turbine halls or large pumping stations, this cable acts as a shielded conduit, protecting weak eddy-current signals from electromagnetic interference (EMI) and mechanical stress. By utilizing low-loss coaxial architecture and ruggedized armor, it ensures the Bently Nevada 3500 system receives the accurate, real-time data necessary for mission-critical emergency shutdown (ESD) decisions.\u003c\/p\u003e\n\u003ch2\u003eSuffix Configuration and Material Analysis\u003c\/h2\u003e\n\u003ch3\u003e330854 - 3300 XL 25mm Extension Cable\u003c\/h3\u003e\n\u003cp\u003eIdentifies the specialized extension cable compatible only with the 3300 XL 25mm proximity probe series, featuring specific capacitance matching for extended range measurements.\u003c\/p\u003e\n\u003ch3\u003e080 - Cable Length\u003c\/h3\u003e\n\u003cp\u003eDesignates a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8.0-meter (26.2 feet)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecable length. When combined with a 1.0-meter probe, this configuration completes a standard 9.0-meter electrical system, ensuring the Proximitor remains calibrated to the sensor.\u003c\/p\u003e\n\u003ch3\u003e25 - Armor and Cable Option\u003c\/h3\u003e\n\u003cp\u003eSpecifies\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eStainless Steel Armor with FEP Jacket\u003c\/strong\u003e. The interlocking stainless steel armor provides superior crush resistance and protection against sharp metal debris, while the Fluorinated Ethylene Propylene (FEP) jacket offers exceptional chemical and moisture resistance.\u003c\/p\u003e\n\u003ch3\u003e05 - Agency Approval Option\u003c\/h3\u003e\n\u003cp\u003eConfirms multiple global hazardous area certifications, including ATEX, IECEx, and North American CSA standards. This allows for safe installation in volatile industrial zones when paired with intrinsically safe barriers.\u003c\/p\u003e\n\u003ch2\u003eMechanical and Electrical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330854-080-25-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85442000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e1.15 kg (2.54 lbs)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e8.0 Meters (26.2 ft)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Diameter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e3.94 mm (0.155 in) without armor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArmored Diameter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e8.89 mm (0.350 in)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51°C to +177°C (-60°F to +351°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e69.9 pF\/m (21.3 pF\/ft) nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.4 mm (1.0 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eField Engineering and Routing Guide\u003c\/h2\u003e\n\u003cp\u003eProper cable management is vital to preventing signal attenuation and \"Not OK\" faults. Engineers must ensure the miniature coaxial connectors are clean and dry before mating; use a dedicated connector protector or heat-shrink tubing to prevent oil ingress in the junction box. When routing the armored cable, respect the 25.4 mm (1.0 inch) minimum bend radius to avoid internal conductor fatigue. Ensure the armor is grounded only at the system monitor end to prevent ground loops. In hazardous area deployments, verify that the cable is secured within conduit or tray systems according to local explosion-proof wiring codes.\u003c\/p\u003e\n\u003ch2\u003eResilience in Extreme Environments\u003c\/h2\u003e\n\u003cp\u003eThe 330854-080-25-05 is built for the harshest corners of the plant floor. The FEP insulation maintains its dielectric properties under extreme thermal cycling—from cryogenic lows to the blistering heat near turbine casings. Its stainless steel armor prevents accidental severing during maintenance activities, while the shielded coaxial core rejects noise from nearby variable frequency drives (VFDs) and high-voltage motor leads. This cable integrates seamlessly with the Bently Nevada 3500\/42M or 3500\/45 modules, providing a stable backbone for Turbine Supervisory Instrumentation (TSI) and integration into Honeywell Experion PKS or Emerson DeltaV platforms.\u003c\/p\u003e\n\u003ch2\u003eLogistics and Dispatch Standards\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDelivery time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3-5 days when payment finish, BY DHL\/FEDEX\/UPS.\u003c\/p\u003e\n\u003cp\u003eWe deliver all extension cables in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanti-static industrial packaging\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith the connectors capped to prevent oxidation and contamination during global transit.\u003c\/p\u003e\n\u003ch2\u003eTechnical Support FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can I use this 8.0m cable with an 8mm or 11mm probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: No. The 330854 is electrically matched specifically for the 25mm system. Using it with 8mm or 11mm probes will cause significant linearity errors and scale factor inaccuracies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the total system length when using this cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: This 8.0m cable is designed to be used with a 1.0m probe, creating a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9.0-meter total system\u003c\/strong\u003e. Ensure your 3300 XL Proximitor is also configured for a 9.0m system length.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How do I identify if the extension cable is faulty?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Use a Bently Nevada TK-3 or a voltmeter to check the bias voltage. A sudden shift to the positive or negative supply rail often indicates a broken center conductor or a short to the armor within the extension cable.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518912651437,"sku":"330854-080-25-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330854-080-25-05-extension-cable-qaurovk0jwe.jpg?v=1766981466","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-330854-080-25-05-3300-xl-25mm-extension-cable","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}