{"product_id":"bently-nevada-330704-000-030-50-02-00-proximity-probes-3300-xl-series","title":"Bently Nevada 330704-000-030-50-02-00 Proximity Probes 3300 XL Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330704-000-030-50-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330704\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probes utilized to execute non-contacting displacement and vibration measurements across 3500 Machinery Protection System platforms. Configured for expanded linear range requirements compared to standard 8 mm probes, this hardware monitors large axial shaft displacements and radial vibrations under demanding physical operational constraints.\u003c\/p\u003e\n\u003ch3\u003eMechanical and Electrical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330704-000-030-50-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.52 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e190 mm x 140 mm x 65 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePower supplied by associated Proximitor Sensor loop\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Linear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.0 mm (160 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Calibration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 4140 Standard Steel target\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSignal Calibration \u0026amp; Cross-Talk Suppression\u003c\/h3\u003e\n\u003cp\u003eThe 11 mm sensor configuration relies on specialized eddy-current probe scaling matrices designed to sustain accurate millivolt-per-mil sensitivity across a wider measurement window. During field installation setup, engineers must perform gap voltage validation (-10 VDC targets) to accurately center the probe within its calibrated linear zone. Due to the extended projection of the RF magnetic field generated by the 11 mm tip diameter, adjacent transducers require greater spatial separation to maintain proper cross-talk suppression. Precise structural mounting ensures the continuous capture of complex rotor dynamics without experiencing magnetic saturation or signal tracking inaccuracies from neighboring machine components.\u003c\/p\u003e\n\u003ch3\u003ePackage Component List\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) Bently Nevada 3300 XL 11 mm Proximity Probe with integrated coaxial connection lead.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThread securement hex nuts for position locking.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQuality assurance calibration verification sheet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding and Ground Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCoaxial extension cable shields must remain completely isolated from the local machine casing and industrial conduit grounds. Terminate the overall shield layer at a single point inside the monitoring rack instrumentation ground plate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThread Engagement Criteria:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInsert the probe body securely into the mounting bracket or sleeve housing. Ensure a minimum of 5 full thread turns engagement to lock the hardware assembly against continuous mechanical machinery vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSide-Wall Clearance Demands:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe wider RF field profile emitted from the 11 mm tip face requires a strict unthreaded clear radius zone. Inadequate side-wall counterbore clearance alters factory calibration curves and shifts the output signal baseline.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLogistics and Dispatch Protocols\u003c\/h2\u003e\n\u003cp\u003eDelivery time: 3-5 days when payment finish via DHL\/FEDEX\/UPS. All units are shipped inside anti-static industrial packaging to negate electrostatic discharge hazards. Heavy-gauge cushioned outer corrugated packaging protects the internal structural elements and critical cable bonds against shock variables during international transport.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this hardware loop support online hot-swap probe replacement rules?\u003c\/p\u003e\n\u003cp\u003eA: No. Disconnecting or reconnecting the probe coaxial connector while the associated Proximitor sensor is fully energized can induce voltage transients that risk triggering false channel alerts or system diagnostic faults.\u003c\/p\u003e\n\u003cp\u003eQ: Why does the 11 mm probe tip configuration demand a larger unthreaded clearance zone?\u003c\/p\u003e\n\u003cp\u003eA: The 11 mm diameter creates a wider RF magnetic field than smaller 5 mm or 8 mm variations, meaning nearby metallic boundaries alter the eddy-current probe scaling profile unless proper clearance boundaries are established.\u003c\/p\u003e\n\u003cp\u003eQ: What action is required if gap voltage validation (-10 VDC targets) cannot be achieved?\u003c\/p\u003e\n\u003cp\u003eA: Verify that the physical distance between the probe tip and the target material complies with installation layout prints, confirm that the target material matches AISI 4140 steel, and clean the probe tip face of metallic particulate accumulation.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518831386797,"sku":"330704-000-030-50-02-00","price":95.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330704-000-030-50-02-00-3300-xl-11-mm-probe-crpproudufy.jpg?v=1766979846","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-330704-000-030-50-02-00-proximity-probes-3300-xl-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}