{"product_id":"bently-nevada-330130-080-03-cn-3300-xl-8m-extension-cable","title":"Bently Nevada 330130-080-03-CN 3300 XL 8m Extension Cable","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Bently Nevada 330130-080-03-CN serves as a critical link in the 3300 XL 8mm proximity transducer system, ensuring flawless transmission of dynamic vibration and static position data from rotating assets. Designed for heavy-duty industrial environments, this 8-meter extension cable bridges the gap between the proximity probe and the Proximitor Sensor with exceptional signal integrity. Its robust construction protects against the electromagnetic noise and harsh physical conditions common in fluid-film bearing machinery, such as large-scale compressors and steam turbines. By maintaining strict electrical impedance, this cable guarantees precise telemetry for emergency shutdown (ESD) systems and plant DCS platforms. Operations teams rely on its stability to prevent catastrophic mechanical failure and optimize predictive maintenance cycles in mission-critical energy applications.\u003c\/p\u003e\n\u003ch2\u003eSuffix Architecture and Engineering Specification\u003c\/h2\u003e\n\u003cp\u003eThe alphanumeric part numbering system for the 3300 XL series facilitates precise hardware identification and regulatory alignment.\u003c\/p\u003e\n\u003ch3\u003e080 - Cable Length Option\u003c\/h3\u003e\n\u003cp\u003eThis designation identifies a total physical length of 8.0 meters (26.2 feet). This length enables flexible routing within large machinery housings while ensuring the total system impedance—when paired with the probe and Proximitor—remains within the calibrated range for the 3300 XL series.\u003c\/p\u003e\n\u003ch3\u003e03 - Armor and Protection\u003c\/h3\u003e\n\u003cp\u003eThe '03' suffix signifies an armored cable construction paired with an integrated connector protector. This design provides maximum defense against mechanical impact, abrasive wear, and localized heat, ensuring the delicate coaxial core remains shielded throughout its service life.\u003c\/p\u003e\n\u003ch3\u003eCN - Regulatory Compliance\u003c\/h3\u003e\n\u003cp\u003eThe 'CN' suffix marks this unit as specifically compliant with Chinese regulatory agency approvals. This certification ensures that the hardware meets mandatory safety and operational standards required for installation within Chinese industrial zones.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States of America\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHS Tariff Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.85 kg (1.87 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e28.0 x 27.0 x 4.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eArmored Coaxial (75 ohm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCapacitance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e69.9 pF\/m (typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 °C to +177 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCompatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 5mm\/8mm Systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eField Engineering and Installation Protocol\u003c\/h2\u003e\n\u003cp\u003eTechnicians must adhere to a minimum cable bend radius of 25.4 mm (1.0 inch) to prevent kinking or internal shield deformation, which would otherwise introduce impedance errors into the vibration signal. When pulling the cable through conduits, maintain low tension to avoid pulling stress on the ClickLoc connector terminals. Always verify that the connector protector is fully seated and tightened, as this prevents moisture and conductive dust from breaching the connection point. Ensure the extension cable is isolated from high-voltage power lines to prevent EMI interference, and verify system ground continuity at the monitor rack before energizing the Proximitor loop.\u003c\/p\u003e\n\u003ch2\u003eEngineering Advantages and TSI Synergy\u003c\/h2\u003e\n\u003cp\u003eThis extension cable thrives in high-temperature, high-vibration zones where standard cables experience rapid degradation. The armored sheath provides a physical barrier against flying debris and corrosive fluids, while the factory-calibrated shielding ensures that the raw eddy current signal remains pristine.\u003c\/p\u003e\n\u003cp\u003eThis cable integrates seamlessly into modern Turbine Supervisory Instrumentation (TSI) architectures. Its design is fully interchangeable with non-XL 3300 components, allowing for simplified upgrades without requiring complex recalibration of existing control loops. By delivering high-fidelity data to monitoring systems like the Bently Nevada 3500 rack, the cable facilitates proactive diagnostics, enabling operators to identify shaft unbalance or rotor instability long before those conditions trigger an automated trip.\u003c\/p\u003e\n\u003ch2\u003eProcurement and Inventory Manifest\u003c\/h2\u003e\n\u003cp\u003e(1) One authentic Bently Nevada 330130-080-03-CN armored extension cable.\u003c\/p\u003e\n\u003cp\u003e(2) Pre-installed connector protectors on both ends for environmental sealing.\u003c\/p\u003e\n\u003cp\u003e(3) Factory-certified documentation confirming CSA, ATEX, and IECEx\/CN compliance.\u003c\/p\u003e\n\u003cp\u003e(4) Threaded protective caps applied to all coaxial termination points for transit safety.\u003c\/p\u003e\n\u003ch2\u003eGlobal Logistics and Dispatch Profile\u003c\/h2\u003e\n\u003cp\u003eOur logistics team dispatches this component within 2-7 days when payment finish protocols complete. We facilitate worldwide distribution via premium carriers like DHL, FEDEX, and UPS to guarantee fast, reliable delivery. Each unit undergoes a stringent final inspection before being encased in specialized anti-static industrial packaging. This ESD-protected, shock-absorbent shielding guards the precision coaxial elements against electrostatic discharge and mechanical impact, ensuring the extension cable arrives in factory-perfect condition for your immediate installation.\u003c\/p\u003e\n\u003ch2\u003eEngineering Support FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can I use this 8-meter extension cable with a 1-meter probe on a system originally designed for a 5-meter total length?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: No, the total system length (probe + extension cable) must match the specific calibration of your Proximitor Sensor. Replacing a 5-meter total system with an 8-meter extension will introduce significant measurement errors and scale factor inaccuracies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the primary difference between the -CN version and the standard international version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: The electrical and physical characteristics are identical; the primary distinction is the regulatory certification labeling required for compliance within specific Chinese market projects.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How do I verify the health of an extension cable after it has been installed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Perform a continuity test between the center conductor on both ends and ensure the outer shield provides low resistance to ground. Any readings indicating high resistance or open circuits confirm internal cable failure, necessitating immediate replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Can I use these armored cables in an environment that exceeds 177 °C?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: While the cable is designed for high-temperature resilience, continuous operation above 177 °C will accelerate the aging of the cable insulation and shielding. In such environments, ensure the cable is routed away from the highest heat sources or utilize dedicated heat-shielding sleeves.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518882767021,"sku":"330130-080-03-CN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330130-080-03-cn-3300-xl-standard-extension-cable-yxlx1dbzr2n.jpg?v=1766980949","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-330130-080-03-cn-3300-xl-8m-extension-cable","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}