{"product_id":"bently-nevada-330130-070-02-05-3300-xl-standard-proximity-extension-cable","title":"Bently Nevada 330130-070-02-05 3300 XL Standard Proximity Extension Cable","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Bently Nevada 330130-070-02-05 standard extension cable forms a high-integrity electrical bridge within the 3300 XL 8mm proximity transducer loop. This specialized coaxial link channels raw high-frequency eddy current signals from field-mounted proximity probes directly to centralized Proximitor sensors. Engineered for critical rotating machinery monitoring setups, it preserves signal purity across challenging physical spaces to ensure exact displacement, shaft vibration, and axial position tracking. Reliability remains vital during operation on massive asset categories like steam turbine generators, heavy industrial compressors, and high-speed process pumps. The cable integrates cleanly with larger Turbine Supervisory Instrumentation (TSI) setups and emergency shutdown networks, supplying the flawless real-time sensor measurements required by distributed control systems (DCS) to execute safety trip commands and protect infrastructure investment.\u003c\/p\u003e\n\u003ch2\u003eConfiguration Matrix and Suffix Engineering\u003c\/h2\u003e\n\u003cp\u003eDeconstructing the exact option digits chosen for this part number defines its mechanical installation layout and site compatibility profile.\u003c\/p\u003e\n\u003ch3\u003eCable Length Suffix (070)\u003c\/h3\u003e\n\u003cp\u003eThis selection specifies a total physical cable length of 7.0 meters (23.0 feet), configuring the standard loop to reach secondary junction panels while maintaining precise internal impedance tuning for the complete circuit.\u003c\/p\u003e\n\u003ch3\u003eCable Armor Option (02)\u003c\/h3\u003e\n\u003cp\u003eThe 02 designator indicates a standard, unarmored coaxial cable configuration. This design provides maximum flexibility for routing through dedicated protective conduit networks or closed internal machine tracking channels.\u003c\/p\u003e\n\u003ch3\u003eAgency Safety Certification (05)\u003c\/h3\u003e\n\u003cp\u003eThis option guarantees comprehensive hazardous area compliance with international standards, securing ATEX, IECEx, and CSA approvals for safe, permanent deployment inside volatile industrial processing zones.\u003c\/p\u003e\n\u003ch2\u003eDimensional Profiles and Technical Performance\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical and Electrical Classifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Values\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8544.42.9090\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.42 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Dimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22.0 cm x 22.0 cm x 4.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Jacket Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFluorinated Ethylene Propylene (FEP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Construction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature coaxial ClickLoc terminals (Gold-plated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Loop Capacity Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFormulated for 9.0-meter total system tuning\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature Threshold\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51°C to +177°C (-60°F to +350°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Insulation Strength\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 V RMS conductor-to-shield isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSite Routing and Mechanical Deployment Guidelines\u003c\/h2\u003e\n\u003ch3\u003eMandatory Cable Bend Radius Boundaries\u003c\/h3\u003e\n\u003cp\u003eMaintain a strict static minimum bend radius of 25.4 mm (1.0 inch) across the entire FEP-insulated cable layout. Bending the coaxial core beyond this limit alters the internal capacitive and inductive matching properties, degrading high-frequency signal clarity.\u003c\/p\u003e\n\u003ch3\u003eClickLoc Connector Interface Security\u003c\/h3\u003e\n\u003cp\u003eEnsure the miniature ClickLoc coaxial terminals lock completely into place when connecting the field probe to the extension line. Wipe the gold-plated surfaces clean of any oily residue before mating, and apply a specialized silicone connector protector sleeve to seal the connection against structural moisture entry.\u003c\/p\u003e\n\u003ch3\u003eElimination of Local Noise Ingress\u003c\/h3\u003e\n\u003cp\u003eRoute the extension cable inside dedicated metallic conduit channels isolated from heavy high-voltage three-phase motor lines. Keeping signal paths separated from power lines blocks electromagnetic cross-talk from corrupting the raw millivolt displacement data destined for your 3500 rack.\u003c\/p\u003e\n\u003ch2\u003eSystem Interoperability and Environmental Endurance\u003c\/h2\u003e\n\u003ch3\u003eSurvivability in Corrosive Plant Zones\u003c\/h3\u003e\n\u003cp\u003eThe high-grade Fluorinated Ethylene Propylene (FEP) external jacket offers superior chemical resistance against vaporized lubricants, aggressive cooling fluids, and continuous moisture exposure. It resists hardening and structural cracking over decades of thermal cycling on high-temperature turbine decks.\u003c\/p\u003e\n\u003ch3\u003eUnified Distributed Architecture Deployment\u003c\/h3\u003e\n\u003cp\u003eThis extension cable delivers clean, unattenuated sensor waveforms over its full length into matching 3300 XL Proximitor units. This clean transmission enables stable, noise-free analog outputs to be streamed directly to automated machinery modules or Honeywell Experion PKS distributed control architectures.\u003c\/p\u003e\n\u003ch2\u003ePackage Inclusions and Ordering Information\u003c\/h2\u003e\n\u003cp\u003e(1) One Bently Nevada 330130-070-02-05 3300 XL Standard Extension Cable.\u003c\/p\u003e\n\u003cp\u003e(2) Factory-terminated male and female gold-plated ClickLoc connectors.\u003c\/p\u003e\n\u003cp\u003e(3) Removable plastic terminal dust shields.\u003c\/p\u003e\n\u003cp\u003e(4) Original manufacturer material trace and quality clearance certificate.\u003c\/p\u003e\n\u003ch2\u003eIndustrial Logistics and Packaging Standard\u003c\/h2\u003e\n\u003cp\u003eWe dispatch your orders within 3-5 days when payment finish, shipping packages globally via premium express services including DHL, FedEx, and UPS to guarantee trackable, secure delivery. Every extension cable is coiled carefully and sealed within dedicated anti-static industrial packaging. This protective layer mitigates electrostatic risk and structural impacts during transit, ensuring your critical monitoring components arrive completely undamaged and ready for field calibration.\u003c\/p\u003e\n\u003ch2\u003eDiagnostic and Application FAQs\u003c\/h2\u003e\n\u003cp\u003eQ1: How do I verify if this 7.0-meter extension cable is matched correctly with my proximity probe?\u003c\/p\u003e\n\u003cp\u003eA1: A 7.0-meter extension cable requires connection to a proximity probe with a 2.0-meter total length option. This combination forms the exact 9.0-meter total electrical loop length required by a standard 9.0V 3300 XL Proximitor sensor.\u003c\/p\u003e\n\u003cp\u003eQ2: Can I pull this unarmored 02 cable option directly through open cable trays on a turbine deck?\u003c\/p\u003e\n\u003cp\u003eA2: While the FEP jacket provides excellent chemical protection, open trays leave the cable vulnerable to crushing or cutting. For exposed paths, pull the cable through a sealed flexible metal conduit to maintain physical armor protection.\u003c\/p\u003e\n\u003cp\u003eQ3: What symptom indicates that an extension cable connector has become contaminated with water or oil?\u003c\/p\u003e\n\u003cp\u003eA3: Contamination degrades insulation resistance, causing a distinct change in the Proximitor sensor's gap voltage output. This issue often triggers an \"Asymmetry\" error or causes erratic, noisy vibration readings on your monitoring screen.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518881259693,"sku":"330130-070-02-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330130-070-02-05-3300-xl-standard-extension-cable-ujulgzuypv2.jpg?v=1766980898","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-330130-070-02-05-3300-xl-standard-proximity-extension-cable","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}