{"product_id":"bently-nevada-330130-045-12-05-3300-xl-proximity-transducer-extension-cable","title":"Bently Nevada 330130-045-12-05 3300 XL Proximity Transducer Extension Cable","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Bently Nevada 330130-045-12-05 extension cable serves as an indispensable backbone for the industry-standard 3300 XL 8mm Proximity Transducer System. This heavy-duty coaxial link executes flawless, low-loss signal transmission between the proximity probe and the Proximitor Sensor, maintaining absolute measurement accuracy across critical industrial machinery. It operates effectively within complex emergency shutdown systems and continuous Turbine Supervisory Instrumentation (TSI) setups, monitoring radial vibration, axial thrust, and shaft position on high-speed steam turbines, heavy compressors, and large scale industrial pumps. By combining superior shielding with optimized capacitance matching, this extension cable eliminates signal degradation in high-frequency environments, delivering precise mechanical data directly to monitoring racks like the Bently Nevada 3500 and integrated DCS platforms to prevent catastrophic mechanical failures.\u003c\/p\u003e\n\u003ch2\u003eModel Option Nomenclature\u003c\/h2\u003e\n\u003ch3\u003e330130 Cable Base Platform\u003c\/h3\u003e\n\u003cp\u003eThis prefix identifies the standard 3300 XL Extension Cable engineered for 8mm proximity probe systems, establishing a ruggedized electrical path with high-grade shielding properties.\u003c\/p\u003e\n\u003ch3\u003eCable Length Code (-045)\u003c\/h3\u003e\n\u003cp\u003eThe 045 suffix specifies a total physical cable length of 4.5 meters (approximately 14.8 feet), completing a standard 5.0-meter system loop when combined with a 0.5-meter proximity probe.\u003c\/p\u003e\n\u003ch3\u003eConnector and Cable Options (-12)\u003c\/h3\u003e\n\u003cp\u003eThis option denotes the integration of fluid-resistant, high-temperature coaxial connectors complete with factory-installed silicone rubber connector protectors, adding vital defense against oil ingress.\u003c\/p\u003e\n\u003ch3\u003eHazardous Area Approval (-05)\u003c\/h3\u003e\n\u003cp\u003eThe 05 option certifies the assembly under multiple global safety frameworks including ATEX, IECEx, and North American standards, authorizing permanent installation inside Zone 0, Zone 1, or Division 1 hazardous locations.\u003c\/p\u003e\n\u003ch2\u003ePhysical and Operational Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter Field\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Engineering Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHS Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8544429090\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Component Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.34 kg (0.75 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePackaging Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e305 mm x 305 mm x 64 mm (12 in x 12 in x 2.5 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePrimary Sheathing Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFluorinated Ethylene Propylene (FEP) Outer Jacket\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Target Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils) linear range\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eContinuous Operating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51°C to +177°C (-60°F to +350°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Total Capacitance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e69.9 pF\/m (21.3 pF\/ft) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnvironmental Ingress Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP68 Equivalent for protected connectors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAbsolute Bend Limit\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.4 mm (1.0 inch) Minimum Radius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eField Installation Requirements\u003c\/h2\u003e\n\u003ch3\u003eConnector Protection Maintenance\u003c\/h3\u003e\n\u003cp\u003eEnsure the factory-installed silicone connector protectors tightly seal the junction between the probe and extension cable. This mechanical barrier prevents cutting fluids, synthetic lubricants, and moisture from penetrating the coaxial junction, which would alter system impedance and disrupt the 200 mV\/mil calibration scale.\u003c\/p\u003e\n\u003ch3\u003eGrounding and Shielding Protocols\u003c\/h3\u003e\n\u003cp\u003eIsolate the extension cable shield from the machine casing or intermediate conduit bodies. Terminate the overall shield exclusively at the Proximitor Sensor end within the dedicated monitor rack to form a single-point ground, preventing stray industrial ground loops from injecting electronic noise into the vibration signal.\u003c\/p\u003e\n\u003ch3\u003eMinimum Routing Bend Radius\u003c\/h3\u003e\n\u003cp\u003eEnforce a minimum physical bend radius of 25.4 mm (1.0 inch) along the entire cable run inside the cable trays or conduits. Avoid pulling the FEP jacket around sharp metallic edges, as tight crimps modify the internal coaxial conductor spacing and cause localized capacitance changes that register as false vibration spikes.\u003c\/p\u003e\n\u003ch2\u003eHeavy-Duty Reliability Benefits\u003c\/h2\u003e\n\u003ch3\u003eExtreme Industrial Survival\u003c\/h3\u003e\n\u003cp\u003eThe advanced FEP jacket delivers comprehensive immunity against aggressive chemical agents, exposure to hot synthetic bearing oil, and volatile environmental conditions. The internal structure maintains rigid mechanical stability and consistent electrical impedance while operating under extreme temperatures from -51°C to +177°C.\u003c\/p\u003e\n\u003ch3\u003eSeamless Distributed Control Integration\u003c\/h3\u003e\n\u003cp\u003eThis extension cable delivers an unaltered analog voltage signal straight to the Proximitor, allowing direct integration into Bently Nevada 3500 processing modules or Honeywell Experion PKS automation architectures. It guarantees zero data lag and high signal fidelity, giving plant operators reliable data to maintain real-time asset health tracking.\u003c\/p\u003e\n\u003ch2\u003eOrdering info\u003c\/h2\u003e\n\u003cp\u003e(1) Bently Nevada 330130-045-12-05 3300 XL Extension Cable.\u003c\/p\u003e\n\u003cp\u003e(2) Pre-installed silicone rubber connector protectors.\u003c\/p\u003e\n\u003cp\u003e(3) Factory-sealed operational documentation and certificate of conformity.\u003c\/p\u003e\n\u003cp\u003e(4) Installation hardware instruction leaflet.\u003c\/p\u003e\n\u003ch2\u003eDispatch and Protective Packaging\u003c\/h2\u003e\n\u003cp\u003eYour order ships within 2-7 days when payment finish, utilizing trusted express logistics providers including DHL, FEDEX, and UPS to ensure rapid transit. Every extension cable is handled under strict anti-static protocols and packed inside specialized anti-static industrial packaging to defend against electromagnetic hazards and mechanical pressure during global transit.\u003c\/p\u003e\n\u003ch2\u003eField Engineering Validation\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What occurs if I connect this 4.5-meter cable to a 3300 XL 1.0-meter proximity probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: Connecting a 4.5-meter extension cable to a 1.0-meter probe creates a total system length of 5.5 meters. Because the 3300 XL Proximitor sensor expects either a 5.0-meter or 9.0-meter tuned system, a 5.5-meter configuration causes severe calibration mismatch, shifts the nominal gap voltage, and introduces unacceptable linearity errors in your vibration readings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What specific advantage does the option code 12 provide over the standard option code 01 connector?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Option 12 includes factory-installed silicone rubber connector protectors directly on the coaxial terminals. This design shields the connection against oil, moisture, and dust penetration in the field, whereas option 01 provides bare connectors that require manual application of self-vulcanizing tape or separate connector protector kits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How do I test the extension cable for physical integrity using a multimeter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Disconnect both ends of the extension cable. Measure the resistance from the center pin of the male connector to the center socket of the female connector; it must indicate a near-zero ohm reading. Next, check the insulation by measuring resistance between the center conductor and the outer shield; this reading must register as infinite ohms (open circuit). Any lower reading indicates internal insulation breakdown.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Can this 330130 extension cable work alongside old, non-XL Bently Nevada 3300 systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: Yes, the 3300 XL extension cable is physically and electrically backward-compatible with standard, non-XL 3300 8mm proximity transducer components. However, mixing XL and non-XL components limits the entire transducer loop performance to the specifications of the standard 3300 series, rather than achieving the enhanced linear range capabilities of a full XL system.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518878933165,"sku":"330130-045-12-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330130-045-12-05-extension-cable-shdj2hymsej.jpg?v=1766980827","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-330130-045-12-05-3300-xl-proximity-transducer-extension-cable","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}