{"product_id":"bently-nevada-330130-040-03-cn-3300-xl-armored-proximity-extension-cable","title":"Bently Nevada 330130-040-03-CN 3300 XL Armored Proximity Extension Cable","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Bently Nevada 330130-040-03-CN extension cable bridges the critical data path between proximity sensor heads and processing Proximitor units. This 3300 XL premium hardware component actively preserves weak high-frequency eddy current signals generated by shaft vibrations and axial thrust position shifts. Built with rigorous shielding parameters, it prevents signal degradation over the telemetry run, supplying uncorrupted raw data to Bently Nevada 3500 rack architectures and modern Distributed Control Systems (DCS). Plant engineers rely on this armored line to ensure immediate, error-free emergency shutdown (ESD) triggers during sudden mechanical failure. Its heavy-duty design makes it indispensable for continuous machine safety across high-velocity assets like turbo-expanders, boiler feed pumps, and power-generation steam turbines.\u003c\/p\u003e\n\u003ch2\u003eCable Suffix \u0026amp; Model Architecture\u003c\/h2\u003e\n\u003cp\u003eThe unique character segments within this part number define the exact length, structural armouring, and localized hazardous area approval path.\u003c\/p\u003e\n\u003ch3\u003e040 - Linear Cable Length\u003c\/h3\u003e\n\u003cp\u003eThis designation specifies a precise 4.0-meter (13.1 feet) operational cable length. It works in tandem with a 1.0-meter proximity probe to create a balanced 5.0-meter tuned proximity transducer loop, ensuring precise impedance matching.\u003c\/p\u003e\n\u003ch3\u003e03 - Shielding and Connector Protection\u003c\/h3\u003e\n\u003cp\u003eThis suffix dictates a flexible, interlocking stainless steel armor sleeve with a pre-installed heavy-duty connector protector. The armor blocks mechanical crushing forces, while the protector seals out airborne moisture and conductive contaminants at the critical terminal point.\u003c\/p\u003e\n\u003ch3\u003eCN - Regional Hazardous Area Approvals\u003c\/h3\u003e\n\u003cp\u003eThe 'CN' suffix confirms official structural testing and localization compliance for dangerous industrial atmospheres. It integrates full global parameters from CSA, ATEX, and IECEx approvals into local industrial regulations, ensuring safe usage in explosive gas and chemical zones.\u003c\/p\u003e\n\u003ch2\u003eMechanical and Electrical Parameters\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eEngineering Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCertified Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States of America\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHS Tariff Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTotal Hardware Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.20 kg (0.44 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Container Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.5 x 22.4 x 3.3 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eArmor Outer Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInterlocking Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCharacteristic Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 \u003cspan class=\"math-inline\"\u003e$\\Omega$\u003c\/span\u003e nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTypical Electrical Capacitance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e69.9 pF\/m (21.3 pF\/ft)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51°C to +177°C (-60°F to +350°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIngress Protection Level\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP65 rated when mated with protector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eField Routing and Engineering Directives\u003c\/h2\u003e\n\u003cp\u003eMaintaining precise electrical matching requires specific routing care during field deployment. Field technicians must keep a minimum cable bend radius of 25.4 mm (1.0 inch) for the armored section to prevent kinking or micro-fracturing of the internal coaxial shielding layers.\u003c\/p\u003e\n\u003cp\u003eWhen pulling the 4.0-meter line through external junction panels, isolate the extension cable from high-voltage AC motor lines to avoid EMI noise pickup. Always use the integrated ClickLoc connector protector kit; thread it down completely to form an oil-tight seal against synthetic machine lubricants and condensation. Ensure the outer armor jacket terminates securely to a local enclosure ground plate to drain off parasitic stray currents.\u003c\/p\u003e\n\u003ch2\u003eHeavy-Industrial Asset Optimization\u003c\/h2\u003e\n\u003cp\u003eThe 330130 armored extension line withstands harsh field installations where extreme heat, flying debris, and constant exposure to caustic turbine oils ruin standard cords. Its advanced fluoropolymer jacket handles temperature spikes up to +177°C without melting or losing calibration stability, maintaining complete signal accuracy across prolonged production runs.\u003c\/p\u003e\n\u003cp\u003eThis high-integrity link seamlessly ties raw physical machinery metrics into advanced Turbine Supervisory Instrumentation (TSI) setups. It relays clean, noise-free analog telemetry to 3500\/42M Proximitor modules, which forward data to automation networks like Honeywell Experion PKS or Siemens S7 architectures. This zero-lag connection lets the host platform calculate real-time shaft orbits, axial shifts, and phase angles, allowing automated emergency trip loops to fire instantly the moment mechanical tolerances drift past safety limits.\u003c\/p\u003e\n\u003ch2\u003eShipping Manifest\u003c\/h2\u003e\n\u003cp\u003e(1) One authentic Bently Nevada 330130-040-03-CN 3300 XL 4.0m armored extension cable.\u003c\/p\u003e\n\u003cp\u003e(2) Factory-installed heavy-duty coaxial connector protector kit.\u003c\/p\u003e\n\u003cp\u003e(3) Sealed terminal protectors guarding both ClickLoc connection ends.\u003c\/p\u003e\n\u003cp\u003e(4) Compliance documentation validating regional safety and explosion-proof parameters.\u003c\/p\u003e\n\u003ch2\u003eLogistics Architecture and High-Density Packaging\u003c\/h2\u003e\n\u003cp\u003eOur specialized logistics unit processes and dispatches orders within 2-7 days from final payment finish verification. We partner with premier global express carriers, including DHL, FEDEX, and UPS, to guarantee fast, fully tracked delivery directly to your facility. Before shipping, technicians run physical checks and seal each cable into heavy-duty anti-static industrial packaging. This ESD-shielded, moisture-barrier containment shields the internal 50\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\Omega$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ecoaxial structure and steel armor from physical deformation and electrostatic build-up during transport, ensuring the component arrives ready for immediate site commissioning.\u003c\/p\u003e\n\u003ch2\u003eTransducer Maintenance \u0026amp; Troubleshooting FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How does a technician determine if the extension cable length matches the Proximitor Sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: The total length of your probe plus the extension cable must match the calibrated system length of the Proximitor Sensor. Because this model is a 4.0-meter extension line, it must connect to a 1.0-meter proximity probe to complete a 5-meter sensor system; pairing it with an incorrect length causes severe scale factor errors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What specific maintenance advantage does the interlocking stainless steel armor provide over standard cables?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: The steel armor forms a rugged mechanical shield that prevents cutting, severe pinching, and abrasion caused by sharp metal shavings or rough handling during machine turnarounds. This shielding protects the delicate inner coaxial core, preventing grounding faults and signal loss.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can this 'CN' approved cable be used in plants that require standard ATEX or IECEx certificates?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Yes. The 'CN' designation incorporates and fulfills core international safety parameters from CSA, ATEX, and IECEx, adding necessary localized compliance marks. This means it installs safely in global Class I, Division 1, or Zone 0 hazardous environments without voiding insurance or safety protocols.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: How do I test if this extension cable has an internal short or a broken wire using a multimeter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: Disconnect both ends of the cable. Use a digital multimeter to measure continuity from the center pin on one end to the center pin on the other; it should read near zero ohms. Next, measure resistance between the center pin and the outer armor shell; an open circuit (infinite resistance) must be present, or the cable has a short.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518882144429,"sku":"330130-040-03-CN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330130-040-03-cn-extension-cable-5xch54k3vhi.jpg?v=1766980925","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-330130-040-03-cn-3300-xl-armored-proximity-extension-cable","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}