{"product_id":"bently-nevada-330130-030-00-00-3300-xl-proximity-transducer-extension-cable","title":"Bently Nevada 330130-030-00-00 3300 XL Proximity Transducer Extension Cable","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Bently Nevada 330130-030-00-00 3300 XL Standard Extension Cable delivers crucial signal transmission integrity within critical machinery protection and condition monitoring architectures. Specifically engineered for demanding rotating machinery assets like steam turbines, compressors, and large pumps, this cable bridges the gap between the proximity probe and the Proximitor sensor. It maintains complete electrical linearity and calibration accuracy under extreme industrial stress. By transmitting raw eddy current data without attenuation, it empowers plant operators to feed precise vibration, thrust, and speed data directly into Bently Nevada 3500 racks or connected DCS environments, preventing catastrophic equipment failure and ensuring automated emergency shutdown systems trip reliably when thresholds breach.\u003c\/p\u003e\n\u003ch2\u003ePart Number Suffix Breakdown\u003c\/h2\u003e\n\u003cp\u003eThe specific ordering matrix for this 3300 XL 8mm extension cable defines its physical and mechanical footprint to guarantee precise system integration.\u003c\/p\u003e\n\u003ch3\u003eCable Length Option (-030)\u003c\/h3\u003e\n\u003cp\u003eThis option specifies a total cable length of 3.0 meters (approximately 9.8 feet). It pairs systematically with specific probe lengths to achieve the required 5-meter or 9-meter total system electrical length.\u003c\/p\u003e\n\u003ch3\u003eConnector Protector and Cable Option (-00)\u003c\/h3\u003e\n\u003cp\u003eThis selection provides standard coaxial cable construction without an integrated connector protector. The configuration targets installations inside dedicated conduit or junction boxes where external mechanical shielding is already present.\u003c\/p\u003e\n\u003ch3\u003eAgency Approval Option (-00)\u003c\/h3\u003e\n\u003cp\u003eThis designation indicates the standard unapproved option, ideal for general-purpose industrial environments or facilities utilizing alternative explosion-proof structural barriers rather than intrinsic safety certifications.\u003c\/p\u003e\n\u003ch2\u003ePhysical and Electrical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHS Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85444290\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.17 kg (0.37 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.4 cm x 25.4 cm x 5.1 cm (10.0 in x 10.0 in x 2.0 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaterial\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFluorinated Ethylene Propylene (FEP) insulated cable jacket\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51°C to +177°C (-60°F to +350°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Capacitance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum Bend Radius\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.4 mm (1.0 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eField Deployment and Engineering Guidelines\u003c\/h2\u003e\n\u003cp\u003eReliable eddy current measurement demands strict adherence to physical and electrical installation constraints during plant commissioning.\u003c\/p\u003e\n\u003ch3\u003eCable Routing and Bend Radius\u003c\/h3\u003e\n\u003cp\u003eMaintain a minimum bend radius of 25.4 mm during installation. Sharp kinks degrade the internal coaxial shielding, modifying the baseline capacitance and introducing noise into the vibration readings. Route the extension cable through dedicated, grounded metal conduit to isolate the high-impedance signal from surrounding high-voltage motor lines and transient electromagnetic interference.\u003c\/p\u003e\n\u003ch3\u003eConnector Integrity and Insulation\u003c\/h3\u003e\n\u003cp\u003eClean all miniature coaxial connectors with electronics-grade isopropyl alcohol before mating. Ensure the ClickLoc connectors seat fully with a tactile click. Wrap the connection point with self-fusing silicone tape rather than standard electrical tape to eliminate moisture ingress and prevent grounding loops caused by the outer shell contacting the cable tray.\u003c\/p\u003e\n\u003ch2\u003eMachinery Integration Benefits\u003c\/h2\u003e\n\u003cp\u003eThis extension cable optimizes signal integrity across the entire Turbine Supervisory Instrumentation (TSI) loop.\u003c\/p\u003e\n\u003ch3\u003eEnvironmental Endurance\u003c\/h3\u003e\n\u003cp\u003eThe FEP jacket resists corrosive chemicals, synthetic lubricants, and high ambient temperatures found near turbine bearings. It maintains mechanical flexibility and electrical insulation values over decades of continuous operation, eliminating signal drift caused by environmental degradation.\u003c\/p\u003e\n\u003ch3\u003eSeamless System Interoperability\u003c\/h3\u003e\n\u003cp\u003eThe matched impedance profile provides a seamless link to 3300 XL Proximitor sensors, transferring micro-ampere eddy current signals without phase lag or amplitude distortion. This ensures flawless data delivery to modern asset management networks like Honeywell Experion PKS or safety-instrumented emergency shutdown systems.\u003c\/p\u003e\n\u003ch2\u003ePackage Content and Ordering Information\u003c\/h2\u003e\n\u003cp\u003eEvery fulfillment contains the necessary components for standard field deployment.\u003c\/p\u003e\n\u003cp\u003e(1) One authentic Bently Nevada 330130-030-00-00 extension cable\u003c\/p\u003e\n\u003cp\u003e(2) Factory calibration certificate and compliance documentation\u003c\/p\u003e\n\u003cp\u003e(3) Removable installation identification tags\u003c\/p\u003e\n\u003cp\u003e(4) Heavy-duty protective connector caps\u003c\/p\u003e\n\u003ch2\u003eLogistics and Packaging Standards\u003c\/h2\u003e\n\u003cp\u003eWe dispatch all orders within 2-7 days following payment confirmation. Every shipment routes via premium global express couriers including DHL, FedEx, or UPS to minimize plant downtime. To preserve the sensitive calibration properties of the internal coaxial components, we enclose each cable inside an anti-static industrial packaging shield packed within a rigid, impact-resistant outer shipping carton.\u003c\/p\u003e\n\u003ch2\u003eTechnical Application Support\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can I use this 3.0-meter extension cable with a 1-meter 3300 XL probe and a 5-meter Proximitor sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: Yes. The total electrical length of the probe plus the extension cable must match the designated length of the Proximitor sensor. A 1-meter probe combined with this 3-meter extension cable creates a 4-meter assembly, which is the correct match for a 5-meter Proximitor sensor because the sensor expects a 4-meter hardware extension ahead of it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How do I identify if a field error is caused by a faulty 330130 extension cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Measure the center conductor to the outer shield resistance using a digital multimeter while the cable is disconnected at both ends. It should show an open circuit (infinity). Next, check the continuity of the center conductor from end to end, which should read very close to 0 ohms. Any measurable resistance between the shield and center conductor indicates moisture ingress or insulation breakdown.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does this cable support older 3300 series 8mm proximity probes, or is it restricted to 3300 XL systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: The 3300 XL extension cable is physically and electrically backward-compatible with non-XL Bently Nevada 3300 series 8mm proximity probe systems. However, mixing XL and non-XL components slightly reduces the system linearity compared to a pure, unmixed 3300 XL setup.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518880440493,"sku":"330130-030-00-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330130-030-00-00-3300-xl-standard-extension-cable-0nrfobrk1vi.jpg?v=1766980866","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-330130-030-00-00-3300-xl-proximity-transducer-extension-cable","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}