{"product_id":"bently-nevada-330105-02-12-10-02-00-8-mm-reverse-mount-proximity-probe-3300-xl-series","title":"Bently Nevada 330105-02-12-10-02-00 8 mm Reverse Mount Proximity Probe 3300 XL Series","description":"\u003cp\u003eConfigured for radial vibration and axial position measurement in rotating machinery, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330105-02-12-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330105-02-12-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 mm Reverse Mount Proximity Probe) provides direct physical monitoring of rotor dynamics within the 3300 XL transducer system.\u003c\/p\u003e\n\u003ch3\u003eConfiguration Matrix\u003c\/h3\u003e\n\u003cp\u003eThis unit is defined by the following specifications:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel: 330105\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTotal Length: 1.0 meter (3.3 feet)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector: Miniature ClickLoc coaxial connector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAgency Approval: Not required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical and Electrical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330105-02-12-10-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.05 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.1 cm x 1 cm x 116 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 Ohm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExtension Cable Capacitance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e69.9 pF\/m (21.3 pF\/ft)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Threads\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8-24 UNF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyphenylene sulfide (PPS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe probe functions as part of an eddy-current proximity system, where a high-frequency radio signal generates a magnetic field at the probe tip. Variations in the distance between the probe and the metallic target (rotor) result in changes in eddy-current energy absorption. The Proximitor sensor converts this impedance change into a voltage signal proportional to the gap. Proper operation requires a linear range validation; typically, the system is calibrated to a -10 VDC target at a nominal gap of 1.27 mm (50 mils). Cross-talk suppression is maintained by adhering to minimum mounting clearance guidelines relative to other probes.\u003c\/p\u003e\n\u003ch3\u003eShipment Contents\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330105-02-12-10-02-00 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated coaxial cable with Miniature ClickLoc connector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtective thread caps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNote: Calibration documentation and mounting brackets are not included unless specified in the purchase order.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Installation Requirements\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure the target surface is free of deep scratches, burrs, or surface discontinuities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe probe must be mounted perpendicular to the target surface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFor reverse mount configurations, verify the probe is installed from the internal side of the housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse the 3\/8-24 UNF threads to secure the probe, ensuring the locking nut is tightened to prevent vibration-induced loosening.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain a minimum distance of 3 times the probe diameter from any other conductive material to prevent signal interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistics and Handling\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDelivery time: 3-5 days after payment completion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLogistics partners: DHL, FEDEX, or UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePackaging: All units are secured in anti-static industrial packaging to ensure transit safety and protection against electrostatic discharge (ESD).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Support Inquiries\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the primary purpose of the ClickLoc connector?\u003c\/p\u003e\n\u003cp\u003eA: It provides a secure, vibration-resistant connection for the coaxial cable, ensuring consistent signal integrity between the probe and the Proximitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this probe be used with non-XL series sensors?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the 3300 XL components are backward compatible with 3300 series 5 mm and 8 mm transducer systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the effect of probe gap on output voltage?\u003c\/p\u003e\n\u003cp\u003eA: The output voltage increases linearly as the gap between the probe tip and the target increases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the cable length field-adjustable?\u003c\/p\u003e\n\u003cp\u003eA: No, the total system length is calibrated for a specific cable length to maintain impedance matching; altering the length will affect accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How should the probe be grounded?\u003c\/p\u003e\n\u003cp\u003eA: The system should be grounded at the Proximitor sensor end, following the standard site instrumentation earthing practices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the maximum operating temperature?\u003c\/p\u003e\n\u003cp\u003eA: The probe is designed for operation in harsh industrial environments; refer to the specific 3300 XL system datasheet for temperature derating curves.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the probe require a specific target material?\u003c\/p\u003e\n\u003cp\u003eA: It is designed for 4140 steel targets; using other materials will require a recalibration of the scale factor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the thread pitch for the mounting body?\u003c\/p\u003e\n\u003cp\u003eA: The mounting body features 3\/8-24 UNF threads for precise mechanical positioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026834739373,"sku":"330105-02-12-10-02-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian12_07648f79-073e-4bc7-9554-cb8e804575c1.jpg?v=1781084238","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-330105-02-12-10-02-00-8-mm-reverse-mount-proximity-probe-3300-xl-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}