{"product_id":"bently-nevada-330104-00-18-10-02-00-3300-xl-8-mm-proximity-probes","title":"Bently Nevada 330104-00-18-10-02-00 3300 XL 8 mm Proximity Probes","description":"\u003cp\u003eConfigured for non-contacting vibration and displacement measurement in 3300 XL monitoring platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330104-00-18-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330104-00-18-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical\/electrical execution for monitoring radial and axial shaft motion.\u003c\/p\u003e\n\u003ch3\u003eSuffix Configuration Matrix\u003c\/h3\u003e\n\u003cp\u003eThe 330104 series utilizes a standardized coding system to define mechanical and electrical properties. The configuration -00-18-10-02-00 specifies the physical length, thread dimensions, connector termination, and material composition required for standard probe installations in industrial machine interfaces.\u003c\/p\u003e\n\u003ch3\u003eTechnical Hardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330104-00-18-10-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 cm x 20 cm x 10 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Driven by Proximitor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyphenylene Sulfide (PPS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCase Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 303 Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTransducer Electrical Integrity\u003c\/h3\u003e\n\u003cp\u003eOptimal performance requires precise eddy-current probe scaling to ensure linear voltage output corresponding to the target gap. Users must verify gap voltage validation (-10 VDC targets) at the Proximitor sensor output during commissioning to ensure the system operates within the calibrated linear range. High-frequency rotor dynamics data acquisition depends on the suppression of electromagnetic noise; therefore, cross-talk suppression is achieved by ensuring the coaxial shielding remains continuous and is grounded exclusively at the monitor end to eliminate ground loop currents.\u003c\/p\u003e\n\u003ch3\u003eOrdering Inclusions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330104-00-18-10-02-00 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegral coaxial cable with connector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStainless steel mounting nuts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical installation manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSurface Preparation: Ensure the target shaft area is free of scratches, burrs, or surface coatings that could affect eddy-current field uniformity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical Mounting: Tighten the probe body into the mounting bracket until it makes contact with the shaft, then back off to the required gap distance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector Handling: Protect the coaxial connector from moisture and contaminants using the included caps until final integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielding: Ensure the cable path is secured using insulated clamps to prevent abrasion and mechanical stress on the coaxial dielectric.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eImpedance Matching: Verify the total system length matches the 5 m or 9 m Proximitor calibration to avoid phase shift errors in the monitored signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLogistics and Transit\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDispatched via DHL\/FEDEX\/UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAll components are secured within anti-static industrial packaging to protect against ESD and mechanical impact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCan this probe be used in 3300 standard (non-XL) systems? No, 3300 XL components are specifically calibrated for 3300 XL Proximitor sensors; intermixing series will cause measurement errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the effect of probe tip damage? Minor scratches on the PPS tip generally do not affect readings, but structural damage will invalidate the calibration curve.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the cable length field-adjustable? No, the length is fixed at the factory. Cutting the cable changes the system capacitance and renders the sensor inaccurate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I identify a ground loop? High-frequency 50\/60 Hz interference observed on the vibration signal usually indicates a ground loop or improper shield termination.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan it be used in hydrogen-cooled environments? Yes, the materials are compatible with standard hydrogen-cooled generator environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is sensitivity maintained? Sensitivity is fixed at 200 mV\/mil (7.87 V\/mm) and is maintained by the matched Proximitor-Probe-Cable set.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes orientation matter for radial measurement? Probes should be installed at 45 degrees relative to the vertical centerline for optimal journal bearing analysis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is the stainless steel case used? It provides corrosion resistance and structural integrity for industrial machine mounting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518846525613,"sku":"330104-00-18-10-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330104-00-18-10-02-00-3300-xl-8-mm-proximity-probes-04llmeslhar.jpg?v=1766980326","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-330104-00-18-10-02-00-3300-xl-8-mm-proximity-probes","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}