{"product_id":"bently-nevada-330104-00-07-50-02-05-3300-xl-m10x1-proximity-probe-sensor","title":"Bently Nevada 330104-00-07-50-02-05 3300 XL M10x1 Proximity Probe Sensor","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Bently Nevada 330104-00-07-50-02-05 3300 XL 8 mm Proximity Probe establishes fail-safe structural tracking for heavy-duty industrial rotating assets. This metric-threaded eddy current transducer reads microscopic variations in radial vibration, axial thrust position, and shaft runout under high-velocity conditions. It streams clean, uncompromised analog signals directly to Bently Nevada 3500 protection monitors and standard Distributed Control Systems (DCS), forming the front-line data defense for automated Emergency Shutdown (ESD) protocols. The highly advanced sensor coil architecture preserves exceptional measurement linearity across fluctuating operational boundaries. By supplying reliable displacement data, this probe helps engineering teams eliminate unexpected downtime on critical steam turbines, high-pressure process compressors, and large utility pumps.\u003c\/p\u003e\n\u003ch2\u003eModel Part Suffix Interpretation\u003c\/h2\u003e\n\u003ch3\u003e330104: 3300 XL 8 mm Proximity Probe with Metric Thread\u003c\/h3\u003e\n\u003cp\u003eThis primary identifier specifies an 8 mm tip diameter probe configuration manufactured with standard M10 x 1 metric structural casing threads.\u003c\/p\u003e\n\u003ch3\u003eUnthreaded Length Designation: -00\u003c\/h3\u003e\n\u003cp\u003eThis selection indicates a 0.0 mm unthreaded sleeve. The stainless steel body carries complete mechanical threads down its entire length, offering maximum adjustment depth within the mounting bracket.\u003c\/p\u003e\n\u003ch3\u003eOverall Case Length Designation: -07\u003c\/h3\u003e\n\u003cp\u003eThis suffix defines a 70 mm physical case length, dictating the precise internal reach of the probe tip inside the machine bearing housing port.\u003c\/p\u003e\n\u003ch3\u003eTotal System Cable Length: -50\u003c\/h3\u003e\n\u003cp\u003eThis option indicates a 5.0-meter (16.4 feet) integrated cable length, running from the probe tip to the terminal end without requiring an intermediate extension line.\u003c\/p\u003e\n\u003ch3\u003eConnector Type and Cable Sleeve: -02\u003c\/h3\u003e\n\u003cp\u003eThis code specifies a miniature coaxial Click-Loc connector paired with standard coaxial cabling, engineered to reduce high-frequency loop attenuation.\u003c\/p\u003e\n\u003ch3\u003eHazardous Area Certification: -05\u003c\/h3\u003e\n\u003cp\u003eThis suffix provides Multiple Approvals certification, validating the probe for immediate deployment within intrinsically safe and explosion-proof zones regulated by ATEX, IECEx, and CSA.\u003c\/p\u003e\n\u003ch2\u003ePhysical Dimensions and Operational Parameters\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eEngineering Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFactory Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHS Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90318040\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.42 kg (0.93 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e170 mm x 170 mm x 60 mm (6.7 in x 6.7 in x 2.4 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCase Tube Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 303 Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Polymer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyphenylene Sulfide (PPS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDynamic Linear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils) total displacement\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor Value\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) when properly matched\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 °C to +177 °C (-60 °F to +350 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnvironmental Enclosure Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP68 rated seal protection for tip and thread assembly\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eField Calibration and Mechanical Requirements\u003c\/h2\u003e\n\u003ch3\u003eVoltage Calibration Adjustment\u003c\/h3\u003e\n\u003cp\u003eThread the M10 probe into the port sleeve while checking the live DC gap voltage at the Proximitor sensor output terminals. Adjust the physical gap clearance until a digital voltmeter displays exactly -10.0 VDC, securing the sensor tip at the precise midpoint of the 3300 XL linear range.\u003c\/p\u003e\n\u003ch3\u003eCable Handling Constraints\u003c\/h3\u003e\n\u003cp\u003eEnforce a rigid minimum bend radius constraint of 25.4 mm (1.0 inch) across the entire 5.0-meter cable run to preserve the internal coaxial geometry. Route the cable through grounded low-voltage conduit channels to block electro-magnetic fields from high-power supply grids.\u003c\/p\u003e\n\u003ch3\u003eClick-Loc Connector Care\u003c\/h3\u003e\n\u003cp\u003eEnsure the miniature coaxial terminal joint remains completely dry and free from grease. Use a calibrated connector protector sleeve or a sealed junction terminal box to shield the connection, preventing fluid ingress from causing insulation resistance drops.\u003c\/p\u003e\n\u003ch2\u003eAsset Synergies and Environmental Resilience\u003c\/h2\u003e\n\u003ch3\u003eCorrosive Medium Shielding\u003c\/h3\u003e\n\u003cp\u003eThe structural 303 stainless steel casing and vacuum-bonded PPS tip withstand continuous exposure to synthetic lubricating oils, hot steam, and chemical washes. The internal coil elements resist thermal breakdown during rapid machinery temperature shifts, eliminating false alarm trips.\u003c\/p\u003e\n\u003ch3\u003eDistributed Control Integration\u003c\/h3\u003e\n\u003cp\u003eThis transducer supplies the high-fidelity analog waveform required by advanced Turbine Supervisory Instrumentation (TSI) suites. It integrates flawlessly with Honeywell Experion PKS platforms, allowing plant operators to execute real-time orbit plots, shaft centerline mapping, and early-stage oil whip diagnosis.\u003c\/p\u003e\n\u003ch2\u003ePackaging Manifest and Ordering Details\u003c\/h2\u003e\n\u003cp\u003eThe standard package contains the following standalone components:\u003c\/p\u003e\n\u003cp\u003e(1) Bently Nevada 330104-00-07-50-02-05 metric probe with integrated 5.0-meter cable line.\u003c\/p\u003e\n\u003cp\u003e(2) Pre-terminated male miniature coaxial Click-Loc connector with a protective silicone cap.\u003c\/p\u003e\n\u003cp\u003e(3) Dedicated metric locking nuts for rigid positioning inside the M10x1 threaded machine port.\u003c\/p\u003e\n\u003cp\u003e(4) Original calibration documentation sheet and material certificate of compliance.\u003c\/p\u003e\n\u003ch2\u003eShipping Methods and Logistics Standards\u003c\/h2\u003e\n\u003ch3\u003eExpedited Freight Routing\u003c\/h3\u003e\n\u003cp\u003eFulfillment units hand over packages to global carriers within 2-7 days when payment finish protocols clear. Materials travel via premium express networks including DHL, FedEx, and UPS to guarantee fast, tracked delivery directly to industrial facilities.\u003c\/p\u003e\n\u003ch3\u003eIndustrial Shielding Protocols\u003c\/h3\u003e\n\u003cp\u003eLogistics personnel enclose every proximity sensor within customized anti-static industrial packaging pouches. This robust physical barrier shields the delicate high-frequency coil layers from mechanical crushing impacts and electrostatic discharges during transcontinental transport.\u003c\/p\u003e\n\u003ch2\u003eTransducer System Support FAQs\u003c\/h2\u003e\n\u003cp\u003eQ1: Can I connect this 5.0-meter probe directly to a standard 5.0-meter extension cable?\u003c\/p\u003e\n\u003cp\u003eA1: No, doing so will cause serious measurement errors. Bently Nevada 3300 XL proximity systems require a total electrical loop length of either 5.0 meters or 9.0 meters. Because this specific probe features an integrated 5.0-meter cable, it functions as a self-contained loop. You must plug it directly into a 5.0-meter calibrated Proximitor sensor without using an extension cable.\u003c\/p\u003e\n\u003cp\u003eQ2: What is the mechanical difference between this 330104 probe and the 330101 model?\u003c\/p\u003e\n\u003cp\u003eA2: The core difference lies in the casing thread type. The 330101 model utilizes standard English imperial threads (3\/8-24 UNF), whereas this 330104 model features standard metric threads (M10 x 1). Always verify the thread profile of your machine's tapped bearing housing port before ordering to prevent cross-threading during field installation.\u003c\/p\u003e\n\u003cp\u003eQ3: How can I diagnose if moisture has penetrated the coaxial connector?\u003c\/p\u003e\n\u003cp\u003eA3: Monitor the output signal for erratic voltage fluctuations or sudden, unexplained vibration spikes on your control display. Disconnect the probe line and check the insulation resistance between the center conductor pin and the outer shield using a megohmmeter at low voltage. A clean, dry sensor path should read infinite resistance; a low megohm reading indicates moisture contamination inside the connector jacket.\u003c\/p\u003e\n\u003cp\u003eQ4: Does the -05 suffix mean this probe requires a specific safety barrier?\u003c\/p\u003e\n\u003cp\u003eA4: Yes, the -05 suffix designates multiple hazardous area approvals, including intrinsic safety. When deploying this sensor in classified hazardous environments, you must route the signal through a certified intrinsic safety barrier inside the control panel to restrict available electrical energy, complying fully with local safety system regulations.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518880833709,"sku":"330104-00-07-50-02-05","price":109.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330104-00-07-50-02-05-3300-xl-8-mm-proximity-probes-h5le1oxoxvl.jpg?v=1766980881","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-330104-00-07-50-02-05-3300-xl-m10x1-proximity-probe-sensor","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}