{"product_id":"bently-nevada-330104-00-07-10-02-00-proximity-probe-3300-xl-8-mm-series","title":"Bently Nevada 330104-00-07-10-02-00 Proximity Probe 3300 XL 8 mm Series","description":"\u003cp\u003eConfigured for non-contact shaft vibration and radial position measurement in 3300 XL monitoring systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330104-00-07-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330104\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct electromagnetic displacement sensing through an eddy-current transducer arrangement. The assembly interfaces with compatible Proximitor Sensor units and extension cables for continuous rotor vibration signal transmission.\u003c\/p\u003e\n\u003ch3\u003eModel Identification\u003c\/h3\u003e\n\u003cp\u003eThe part number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330104-00-07-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eidentifies a fixed 3300 XL 8 mm proximity probe configuration with factory-defined cable length, connector orientation, and mounting hardware selections. No additional suffix decoding data was provided for this configuration.\u003c\/p\u003e\n\u003ch3\u003eMechanical and Electrical Data\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330104-00-07-10-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProximity Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Diameter\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Principle\u003c\/td\u003e\n\u003ctd\u003eEddy-current non-contact displacement sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Interface\u003c\/td\u003e\n\u003ctd\u003eCompatible with 3300 XL Proximitor systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003eDynamic shaft vibration monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Thread\u003c\/td\u003e\n\u003ctd\u003eMetric threaded probe body\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eCoaxial ClickLoc style connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eIntegral low-noise coaxial cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003e100 percent shield coverage for EMI reduction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Material\u003c\/td\u003e\n\u003ctd\u003eStainless steel housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL probe system components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGap Reference Target\u003c\/td\u003e\n\u003ctd\u003eNominal -10 VDC gap setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial monitoring environment installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSupplied through associated Proximitor sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003eApproximately 24 cm x 18 cm x 4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eGap Voltage Validation Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL probe system uses calibrated eddy-current scaling referenced through the associated Proximitor Sensor assembly. Initial installation commonly targets approximately -10 VDC static gap voltage during shaft positioning. Final probe extension and mechanical alignment must maintain stable linear response across the intended rotor displacement range.\u003c\/p\u003e\n\u003cp\u003eCable routing practices should maintain separation from high-current motor conductors and variable-frequency drive output wiring. Parallel cable runs increase the possibility of electromagnetic coupling and cross-talk between adjacent transducer channels.\u003c\/p\u003e\n\u003ch3\u003eTechnical Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the probe be connected directly to a PLC analog input channel?\u003cbr\u003eA: No. The probe requires an associated Proximitor Sensor for signal conditioning and calibrated displacement output generation.\u003c\/p\u003e\n\u003cp\u003eQ: Does the probe assembly support hot replacement during machine operation?\u003cbr\u003eA: Probe replacement is normally performed during equipment shutdown to avoid accidental rotor contact and incorrect gap adjustment.\u003c\/p\u003e\n\u003cp\u003eQ: What occurs if the probe gap voltage drifts outside the linear range?\u003cbr\u003eA: The displacement output can become nonlinear, causing inaccurate vibration amplitude and shaft position measurements.\u003c\/p\u003e\n\u003cp\u003eQ: Is shield grounding required at both cable ends?\u003cbr\u003eA: Grounding is typically implemented at a single instrumentation reference point to reduce ground loop current paths.\u003c\/p\u003e\n\u003cp\u003eQ: Can multiple proximity probe cables share the same conduit with power cables?\u003cbr\u003eA: Shared routing with high-voltage or switching conductors is not recommended due to induced electrical interference.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eBefore installation, verify probe thread compatibility and mounting bracket alignment. Excessive side loading on the probe body can distort the sensing axis and alter calibration response.\u003c\/p\u003e\n\u003cp\u003eMaintain adequate clearance between the probe tip and rotating shaft during insertion. Probe extension should be adjusted gradually while monitoring gap voltage from the associated monitor or Proximitor output.\u003c\/p\u003e\n\u003cp\u003eAvoid sharp cable bend radii near connector terminations. Cable shielding continuity should remain intact across all field junctions and extension cable interfaces.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330104-00-07-10-02-00 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegral coaxial cable assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtective connector cap\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFactory identification label\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistics Information\u003c\/h3\u003e\n\u003cp\u003eShipment is normally processed within 2-7 days after payment confirmation. Transport is performed through DHL, FedEx, or UPS using anti-static industrial packaging with vibration-resistant internal protection materials.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518834073773,"sku":"330104-00-07-10-02-00","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330104-00-07-10-02-00-3300-xl-8-mm-proximity-probes-gaudlm3qudu.jpg?v=1766979961","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-330104-00-07-10-02-00-proximity-probe-3300-xl-8-mm-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}