{"product_id":"bently-nevada-330104-00-03-10-01-00-3300-xl-8mm-proximity-transducer-probe","title":"Bently Nevada 330104-00-03-10-01-00 3300 XL 8mm Proximity Transducer Probe","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Bently Nevada 330104-00-03-10-01-00 eddy current proximity probe acts as a premier non-contact displacement sensor engineered for reverse-mount installations on high-performance rotating assets. This 8mm transducer excels at capturing high-frequency shaft vibration, axial thrust positioning, and phase reference measurements on critical machinery, including gas turbines, high-speed gearboxes, and large process compressors. Delivering an exceptionally accurate analog output directly to Bently Nevada 3500 protection panels and plant-wide DCS architectures, it ensures continuous machine health monitoring. Heavy industrial facilities deploy this robust sensor inside emergency shutdown systems (ESD) and Turbine Supervisory Instrumentation (TSI) loops to eliminate unexpected machinery breakdowns, optimize maintenance scheduling, and maintain absolute structural safety across continuous manufacturing plants.\u003c\/p\u003e\n\u003ch2\u003eHardware Option Code Breakdown\u003c\/h2\u003e\n\u003ch3\u003e330104 Base Instrument Model\u003c\/h3\u003e\n\u003cp\u003eThis denotes a 3300 XL 8mm Proximity Probe designed specifically for reverse-mount applications, featuring a 3\/8-24 UNF threaded body that integrates smoothly into standard bracket housings or external probe sleeves.\u003c\/p\u003e\n\u003ch3\u003eUnthreaded Length Identifier (-00)\u003c\/h3\u003e\n\u003cp\u003eThe 00 suffix indicates zero unthreaded length on the probe casing. The entire metallic body utilizes continuous threading, giving field engineers maximum adjustability inside deep or customized mounting brackets.\u003c\/p\u003e\n\u003ch3\u003eOverall Case Length Suffix (-03)\u003c\/h3\u003e\n\u003cp\u003eThis option specifies a short 0.3-inch total case length. This ultra-compact profile optimizes the assembly for tight internal machinery recesses and specialized reverse-mount housings where longer probe bodies cannot fit.\u003c\/p\u003e\n\u003ch3\u003eTotal System Cable Length (-10)\u003c\/h3\u003e\n\u003cp\u003eThe 10 code establishes a 1.0-meter (approximately 3.3 feet) integrated flexible cable length. This standard configuration links perfectly with a 4.0-meter or 8.0-meter 3300 XL extension cable to form a complete 5.0-meter or 9.0-meter calibrated transducer system.\u003c\/p\u003e\n\u003ch3\u003eMiniature Connector Variant (-01)\u003c\/h3\u003e\n\u003cp\u003eThis option provides a standard miniature coaxial ClickLoc connector on the cable termination point. It provides a robust, low-loss electrical interface engineered to snap firmly into the matching extension cable terminal.\u003c\/p\u003e\n\u003ch3\u003eCompliance and Agency Approvals (-00)\u003c\/h3\u003e\n\u003cp\u003eThe 00 suffix indicates the base uncertified configuration. This configuration suits standard commercial installations that do not require specialized explosive-proof or intrinsic safety certifications for hazardous environments.\u003c\/p\u003e\n\u003ch2\u003eMechanical and Performance Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter Criteria\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Mechanical Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHS Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9031900090\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Probe Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.15 kg (0.33 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Box Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e228 mm x 228 mm x 40 mm (9 in x 9 in x 1.6 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCasing Structural Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 303 Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Polymer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyphenylene Sulfide (PPS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTotal Linear Measurement Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils) nominal scale\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor Sensitivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnvironmental Ingress Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP68 Rated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperational Thermal Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51°C to +177°C (-60°F to +350°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eField Installation Guidelines\u003c\/h2\u003e\n\u003ch3\u003eElectrical Gap Optimization\u003c\/h3\u003e\n\u003cp\u003eAdjust the physical spacing between the probe tip and the target shaft surface using a digital multimeter connected to the Proximitor sensor loop. Position the reverse-mount housing until the DC output voltage reads exactly -10.0 Vdc, indicating the precise center of the 80-mil linear operational range.\u003c\/p\u003e\n\u003ch3\u003eRouting Bend Management\u003c\/h3\u003e\n\u003cp\u003eMaintain a strict minimum bend radius of 25.4 mm (1.0 inch) for the 1.0-meter integrated cable along the entire routing path. Avoid creating tight pinches or pulling the cable over sharp casing internal borders, as physical cable deformation changes system capacitance and compromises measurement fidelity.\u003c\/p\u003e\n\u003ch3\u003eMechanical Locking Security\u003c\/h3\u003e\n\u003cp\u003eAlways secure the reverse-mount probe using double jam nuts or a verified thread-locking compound during installation. Heavy rotational vibration can cause unsecured threads to back out, shifting the calibrated gap distance and disrupting critical machinery protection signals.\u003c\/p\u003e\n\u003ch2\u003eIndustrial Environmental Resilience\u003c\/h2\u003e\n\u003ch3\u003eChemical and Fluid Submersion Immunity\u003c\/h3\u003e\n\u003cp\u003eThe combination of a high-strength PPS tip and a 303 stainless steel body protects the sensor against high-pressure turbomachinery oil mist, ammonia vapors, and water ingress. The internal circuitry maintains absolute electrical stability from -51°C to +177°C, allowing the sensor to deliver accurate micro-inch readings through extreme temperature fluctuations.\u003c\/p\u003e\n\u003ch3\u003eNative Automation Integration\u003c\/h3\u003e\n\u003cp\u003eThe raw analog output couples flawlessly with Honeywell Experion PKS, Emerson DeltaV, and Siemens S7 architectures via intermediate Proximitor components. This hardware synergy enables near-instantaneous transmission of machinery dynamics, allowing the automation network to activate protection interlocks and execute safe emergency shutdowns.\u003c\/p\u003e\n\u003ch2\u003eOrdering info\u003c\/h2\u003e\n\u003cp\u003e(1) Bently Nevada 330104-00-03-10-01-00 3300 XL 8mm Probe.\u003c\/p\u003e\n\u003cp\u003e(2) Integrated 1.0-meter low-noise coaxial cable.\u003c\/p\u003e\n\u003cp\u003e(3) Miniature coaxial ClickLoc male terminal connector.\u003c\/p\u003e\n\u003cp\u003e(4) Factory-stamped product calibration datasheet.\u003c\/p\u003e\n\u003ch2\u003eWorldwide Logistics and Protective Packaging\u003c\/h2\u003e\n\u003cp\u003eOrders ship rapidly within 2-7 days when payment finish, utilizing premier courier systems such as DHL, FEDEX, and UPS to guarantee fast, traceable transit. Our logistics specialists pack every proximity probe inside robust, custom-molded anti-static industrial packaging to neutralize physical vibration shock and eliminate electrostatic discharge risks during international transport.\u003c\/p\u003e\n\u003ch2\u003eTransducer Field Troubleshooting\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What unique mechanical advantage does a reverse-mount probe body like the 330104 provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: The reverse-mount configuration allows the probe to install from the outside of the machine casing via a specialized housing sleeve. This design permits field engineers to replace, inspect, or re-gap the probe while the machinery remains running, eliminating the need to dismantle the main bearing housing or halt production.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How can I verify if the internal probe coil has failed or shorted?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Disconnect the probe from the extension cable and attach a digital multimeter across the inner pin and outer ring of the ClickLoc connector. A functional 3300 XL 8mm probe with a 1.0-meter cable exhibits a continuous DC resistance value between 5.9 and 7.7 ohms. A reading approaching zero ohms indicates a short circuit, while a reading of infinity confirms an open coil loop.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can I connect this 330104 probe directly to a 3300 XL Proximitor sensor without an extension cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: No. The 3300 XL Proximitor sensor requires a specific electrical length of either 5.0 meters or 9.0 meters to maintain its accurate 200 mV\/mil scale factor. Connecting a 1.0-meter probe directly causes a massive impedance mismatch, leading to severe calibration errors and rendering the output unusable for your machinery protection system.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518878802093,"sku":"330104-00-03-10- 01-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330104-00-03-10-01-00-3300-xl-8-mm-proximity-probes-1g4hvg1ohkz.jpg?v=1766980822","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-330104-00-03-10-01-00-3300-xl-8mm-proximity-transducer-probe","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}