{"product_id":"bently-nevada-330102-00-27-10-02-05-3300-xl-8-mm-proximity-transducer-probe","title":"Bently Nevada 330102-00-27-10-02-05 3300 XL 8 mm Proximity Transducer Probe","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Bently Nevada 330102-00-27-10-02-05 establishes an uncompromising benchmark for industrial-grade vibration monitoring, utilizing advanced eddy current technology to deliver non-contacting shaft displacement analysis. Engineered specifically as a reverse-mount configuration, this 3300 XL 8 mm proximity probe thrives in specialized internal bearing housings and confined rotating machinery envelopes. It monitors microscopic oil-film clearance deviations, thermal growth, and radial vibration profiles in high-speed steam turbines, heavy compressors, and large-scale industrial pumps. The transducer feeds continuous, drift-free analog metrics straight into the Bently Nevada 3500 protection rack or core plant Distributed Control Systems (DCS). By serving as a critical hardware link for Emergency Shutdown (ESD) protocols, it empowers engineering teams to detect structural anomalies early, protect multi-million dollar assets, and maintain plant uptime in severe hazardous environments.\u003c\/p\u003e\n\u003ch2\u003eSuffix Parameter Matrix\u003c\/h2\u003e\n\u003cp\u003eBently Nevada employs a standardized alphanumeric suffix code to dictate the precise mechanical dimensions, cable lengths, and global safety ratings of the 3300 XL series.\u003c\/p\u003e\n\u003ch3\u003e330102 Base Model Designator\u003c\/h3\u003e\n\u003cp\u003eThis number indicates a 3300 XL 8 mm reverse-mount proximity probe featuring a 3\/8-24 UNF thread pattern.\u003c\/p\u003e\n\u003ch3\u003eUnthreaded Length Option (-00)\u003c\/h3\u003e\n\u003cp\u003eThe 00 assignment indicates a 0.0-inch unthreaded length, meaning the structural threads run fully across the body case to allow absolute depth customization inside the mounting bracket.\u003c\/p\u003e\n\u003ch3\u003eOverall Case Length (-27)\u003c\/h3\u003e\n\u003cp\u003eThe 27 suffix establishes an overall case length of 2.7 inches, offering an extended body depth optimized for deep-set machine housing penetrations.\u003c\/p\u003e\n\u003ch3\u003eTotal System Length (-10)\u003c\/h3\u003e\n\u003cp\u003eThe 10 code specifies a 1.0-meter (3.3 feet) integrated probe cable length, terminated with a miniature gold-plated coaxial connector.\u003c\/p\u003e\n\u003ch3\u003eCable Protection Option (-02)\u003c\/h3\u003e\n\u003cp\u003eThe 02 suffix denotes flexible stainless steel armor wrapping the entire length of the cable, shielding the underlying signal conductors from physical tearing and aggressive cutting fluids.\u003c\/p\u003e\n\u003ch3\u003eHazardous Area Approval (-05)\u003c\/h3\u003e\n\u003cp\u003eThe 05 configuration unlocks comprehensive global safety compliance, providing full ATEX, IECEx, and CSA intrinsic safety and non-incendive certifications for hazardous industrial zones.\u003c\/p\u003e\n\u003ch2\u003eAsset Hardware Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eEngineering Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCertified Metric Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHS Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90318080\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApproximate Net Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.38 kg (0.84 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Enclosure Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e21.0 cm x 21.0 cm x 5.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStructural Case Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e303 Stainless Steel (AISI 303)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Compound\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyphenylene Sulfide (PPS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Measurement Span\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils) total displacement range\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Scale Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) nominal stability\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCore Operating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51°C to +177°C (-60°F to +350°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Classification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP68 rated against continuous moisture and oil ingress\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eField Deployment Protocol\u003c\/h2\u003e\n\u003cp\u003eMechanical centering dictates long-term instrumentation precision. Field technicians must monitor the DC gap voltage at the Proximitor Sensor terminals with a calibrated digital multimeter during physical positioning. Screw the reverse-mount body into the sleeve adapter until the multimeter measures a stable -10.0 VDC, which confirms that the target shaft rests exactly in the center of the probe’s linear calibration window.\u003c\/p\u003e\n\u003cp\u003eObserve strict structural layout rules for the armored extension cable. The stainless steel conduit requires a minimum physical bend radius of 25.4 mm (1.0 inch) to protect the internal coaxial core from impedance degradation. Technicians must contain the miniature coaxial connectors inside a dedicated, weatherproof junction box to eliminate fluid contamination. Isolate the probe body from local structural grounds, routing the shield drain wire to earth exclusively at the centralized 3500 rack chassis terminal strip.\u003c\/p\u003e\n\u003ch2\u003eCritical Infrastructure Compatibility\u003c\/h2\u003e\n\u003cp\u003eThis 3300 XL probe withstands the brutal operating conditions of modern heavy industry, including extreme thermal shocks, high pressure, and exposure to corrosive gas compounds. It forms the foundation of robust Turbine Supervisory Instrumentation (TSI) retrofits. The sensor transmits a clean, noise-free analog signal over long distances straight into premium process platforms such as Honeywell Experion PKS or Siemens S7 PLC architectures. This seamless hardware integration provides plant asset management software with the continuous, real-time data streams required for executing high-reliability predictive maintenance modeling.\u003c\/p\u003e\n\u003ch2\u003eProcurement Inventory Check\u003c\/h2\u003e\n\u003cp\u003eEvery dedicated dispatch package includes the definitive mechanical components necessary for quick field commissioning. The factory carton contains:\u003c\/p\u003e\n\u003cp\u003e(1) New Bently Nevada 330102-00-27-10-02-05 reverse-mount proximity probe with a 1.0-meter armored cable.\u003c\/p\u003e\n\u003cp\u003e(2) Factory-milled locknuts to secure the final physical positioning inside the mounting sleeve.\u003c\/p\u003e\n\u003cp\u003e(3) Removable rubber connector sleeves to shield the miniature coaxial link during tight conduit pulls.\u003c\/p\u003e\n\u003cp\u003e(4) Complete material traceability documentation and the original manufacturer linear calibration certificate.\u003c\/p\u003e\n\u003ch2\u003eLogistics and Supply Chain Execution\u003c\/h2\u003e\n\u003cp\u003eOur global logistics infrastructure prioritizes prompt delivery and equipment protection.\u003c\/p\u003e\n\u003ch3\u003eDispatch Window\u003c\/h3\u003e\n\u003cp\u003eYour tracking data generates within 2-7 days when payment finish, utilizing premier global express carriers including DHL, FEDEX, or UPS to achieve rapid customs clearance and cross-border transport.\u003c\/p\u003e\n\u003ch3\u003eIndustrial Boxing Integrity\u003c\/h3\u003e\n\u003cp\u003eWe ship all sensitive proximity sensors encased in specialized anti-static industrial packaging and form-fitting impact-absorbent foam padding, neutralizing electrostatic discharge vectors and rough transit shocks.\u003c\/p\u003e\n\u003ch2\u003eApplication Engineering FAQ\u003c\/h2\u003e\n\u003ch3\u003eQ1: What makes the 330102 reverse-mount probe different from a standard 330101 front-mount probe?\u003c\/h3\u003e\n\u003cp\u003eA1: The 330102 reverse-mount probe installs from the rear into a separate housing or mounting sleeve, making it ideal for situations where you must adjust or replace the probe from outside the machine casing without removing the main bearing cover.\u003c\/p\u003e\n\u003ch3\u003eQ2: What does the -02 option signify regarding the cable construction?\u003c\/h3\u003e\n\u003cp\u003eA2: The -02 option specifies a rugged stainless steel armor layer over the coaxial cable line. This flexible metal conduit prevents physical cuts, pinches, and abrasion from metal shavings or tools inside the machine housing.\u003c\/p\u003e\n\u003ch3\u003eQ3: Can I connect this 1.0-meter probe directly to a 3300 XL Proximitor Sensor without an extension cable?\u003c\/h3\u003e\n\u003cp\u003eA3: No, you cannot bypass the extension cable. The standard 3300 XL Proximitor Sensor requires a total system length of either 5.0 meters or 9.0 meters. Because this probe length measures 1.0 meter, you must use a matching 4.0-meter or 8.0-meter extension cable to maintain the calibrated 200 mV\/mil scale factor.\u003c\/p\u003e\n\u003ch3\u003eQ4: How does a DC gap voltage reading of -2.0 VDC affect system operation?\u003c\/h3\u003e\n\u003cp\u003eA4: A reading of -2.0 VDC indicates that the probe tip sits too close to the target shaft, placing the sensor outside its calibrated linear range. This low voltage will trigger a \"Not OK\" fault status on your Bently Nevada 3500 monitor monitor rack, disabling the channel's trip logic until you re-gap the probe to -10.0 VDC.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518871953581,"sku":"330102-00-27-10-02-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330102-00-27-10-02-05-3300-xl-8-mm-proximity-probes-abwtdvcfzzk.jpg?v=1766980703","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-330102-00-27-10-02-05-3300-xl-8-mm-proximity-transducer-probe","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}