{"product_id":"bently-nevada-330101-33-53-10-02-05-3300-xl-8-mm-proximity-probes","title":"Bently Nevada 330101-33-53-10-02-05 3300 XL 8 mm Proximity Probes","description":"\u003cp\u003eConfigured for shaft vibration and radial displacement measurement in Bently Nevada TSI monitoring systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330101-33-53-10-02-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330101\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct electrical execution through non-contact eddy-current sensing. The probe assembly converts shaft movement into proportional voltage signals for continuous machinery condition monitoring and gap verification.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eSuffix Segment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330101\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e33\u003c\/td\u003e\n\u003ctd\u003eProbe mounting\/thread configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e53\u003c\/td\u003e\n\u003ctd\u003eProbe case length specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003eCable length option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eConnector and approval configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eAgency or accessory revision designation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330101-33-53-10-02-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProximity Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 28 cm x 22 cm x 6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive sensing assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Diameter\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Principle\u003c\/td\u003e\n\u003ctd\u003eEddy-current non-contact transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eDynamic vibration and static position signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003eShielded coaxial cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eClickLoc coaxial connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Method\u003c\/td\u003e\n\u003ctd\u003eThreaded probe mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Material\u003c\/td\u003e\n\u003ctd\u003eConductive metallic surfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCross-Talk Suppression and Gap Voltage Validation\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL transducer system uses controlled cable impedance and shield continuity to maintain stable eddy-current probe scaling across multiple monitoring channels. Cross-talk suppression becomes increasingly important in turbine and compressor installations where multiple probes are routed through common cable trays or junction assemblies.\u003c\/p\u003e\n\u003cp\u003eGap voltage validation is typically performed during commissioning by adjusting probe distance relative to the shaft surface. Standard setup procedures commonly target approximately -10 VDC to confirm acceptable linear operating range and proper rotor centerline positioning.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 330101-33-53-10-02-05 probe operate with non-matched extension cables?\u003cbr\u003eA: System calibration accuracy depends on matched probe, extension cable, and Proximitor components specified for the transducer system.\u003c\/p\u003e\n\u003cp\u003eQ: Does the probe require direct shaft contact during operation?\u003cbr\u003eA: No. The sensing method uses a non-contact electromagnetic field between the probe tip and conductive target surface.\u003c\/p\u003e\n\u003cp\u003eQ: Can probe cables be routed in the same conduit as motor feeders?\u003cbr\u003eA: Separate routing is recommended to reduce induced electrical noise and prevent interference with low-level vibration signals.\u003c\/p\u003e\n\u003cp\u003eQ: What condition may cause unstable gap voltage readings?\u003cbr\u003eA: Improper grounding, connector contamination, excessive cable bending, or loose coaxial connections may affect signal stability.\u003c\/p\u003e\n\u003cp\u003eQ: Is probe replacement permitted while the monitoring rack remains energized?\u003cbr\u003eA: Monitoring channels should be inhibited or isolated before probe replacement to avoid false machinery protection alarms.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eVerify threaded probe alignment before final mounting torque is applied. Misalignment may reduce measurement linearity or cause probe tip damage.\u003c\/p\u003e\n\u003cp\u003eMaintain minimum bending radius requirements for coaxial cable routing near probe bodies and connector transitions.\u003c\/p\u003e\n\u003cp\u003eAvoid cable tray routing adjacent to generator excitation systems, relay switching circuits, or variable frequency drive output wiring.\u003c\/p\u003e\n\u003cp\u003eInspect connector interfaces for oxidation, metallic debris, or oil contamination before electrical connection.\u003c\/p\u003e\n\u003cp\u003eConfirm shield grounding methods according to Bently Nevada installation documentation to minimize ground loop interference.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cp\u003e(1) Shipment includes one Bently Nevada 330101-33-53-10-02-05 proximity probe assembly.\u003c\/p\u003e\n\u003cp\u003e(2) Factory-installed shielded cable and connector hardware are included with the supplied probe.\u003c\/p\u003e\n\u003cp\u003e(3) Compatible extension cables and Proximitor sensors are supplied separately unless specified within the procurement package.\u003c\/p\u003e\n\u003cp\u003e(4) Optional associated monitoring hardware includes Bently Nevada 3300 XL and 3500 series machinery protection modules.\u003c\/p\u003e\n\u003ch3\u003eExport Packaging and Transit Handling\u003c\/h3\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish. Shipment arranged through DHL, FEDEX, or UPS industrial transport services.\u003c\/p\u003e\n\u003cp\u003eEach unit is packed using anti-static industrial packaging with moisture-resistant barrier protection and reinforced carton cushioning for international transit handling.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518866743469,"sku":"330101-33-53-10-02-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330101-33-53-10-02-05-3300-xl-8-mm-proximity-probes-xddekc5b5dy.jpg?v=1766980546","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-330101-33-53-10-02-05-3300-xl-8-mm-proximity-probes","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}