{"product_id":"bently-nevada-330101-00-85-05-01-05-3300-xl-8-mm-probe-proximity-sensors-3300-xl-series","title":"Bently Nevada 330101-00-85-05-01-05 3300 XL 8 mm Probe Proximity Sensors 3300 XL Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330101-00-85-05-01-05\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330101\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe, operates as a dedicated hardware component for non-contacting vibration and displacement measurements within 3300 XL Series machinery protection platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Nomenclature Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330101\u003c\/strong\u003e: 3300 XL 8 mm Probe, 3\/8-24 UNF thread, without armor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-00\u003c\/strong\u003e: Unthreaded length (0.0 in)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-85\u003c\/strong\u003e: Overall case length (8.5 in)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-05\u003c\/strong\u003e: Total length (0.5 m \/ 1.6 ft)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-01\u003c\/strong\u003e: Miniature coaxial ClickLoc connector, fluid-resistant boot\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-05\u003c\/strong\u003e: Standard Bureau Veritas (BV) marine and hazardous area approvals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical and Electrical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330101-00-85-05-01-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.18 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.0 cm x 20.0 cm x 5.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive element (driven by Proximitor Sensor loop)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils) starting at approximately 0.25 mm (10 mils) from target\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) when paired with 3300 XL Proximitor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 meter probe length (must match overall 5.0 or 9.0 meter system configuration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Signal Verification and Scaling\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL 8 mm probe operates on eddy-current principles, requiring explicit calibration matching the target metallurgy (standard AISI 4140 steel). Field installation requires precise gap voltage validation to anchor the nominal mechanical center point. Technicians must monitor the DC bias voltage via the Proximitor sensor output, adjusting the physical position until reaching the target -10.0 VDC gap voltage, which corresponds to the midpoint of the linear calibration envelope. Cross-talk suppression is structurally managed through the geometry of the 8 mm tip and coaxial shielding, preventing magnetic field overlap when multiple probes are installed in tight radial proximity on rotor bearing housings.\u003c\/p\u003e\n\u003ch3\u003ePackage Manifest\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Bently Nevada 330101-00-85-05-01-05 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 x Hexagonal locknuts (3\/8-24 UNF thread)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Silicone connector protector boot (pre-installed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Factory calibration and compliance certificate pack\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eProper mechanical installation is mandatory to avoid probe tip shearing or signal deterioration. The probe must be threaded into the bracket using a calibrated clearance gauge or by measuring the DC gap voltage dynamically. Ensure the probe tip maintains a clear unthreaded path to prevent side-wall interference from the mounting port; any adjacent metal within a 16 mm diameter cylinder around the tip will cause eddy-current field distortion and skew the scale factor. The miniature coaxial ClickLoc connector must be hand-tightened until a positive click is felt. Do not use pliers or wrenches on the coaxial connector. Route the probe lead through dedicated flexible conduit, ensuring the minimum bend radius of 25.4 mm is never compromised. Extension cable connections must be isolated from ground loops using connector protectors or insulating heat-shrink sleeves.\u003c\/p\u003e\n\u003ch3\u003eLogistics and Packaging Data\u003c\/h3\u003e\n\u003cp\u003eDelivery time is 2-7 days when payment finish, routed via DHL\/FEDEX\/UPS premium express channels to ensure structural integrity during transit. All units are encased in specialized anti-static industrial packaging, utilizing sealed moisture-barrier bags accompanied by form-fitting high-density polyethylene foam inserts to protect the integrated coaxial lead and delicate ceramic tip assembly from mechanical shock during international freight handling.\u003c\/p\u003e\n\u003ch3\u003eTechnical Clarification Notes\u003c\/h3\u003e\n\u003cp\u003eQ: What is the procedure if the gap voltage cannot stabilize at -10 VDC during installation?\u003c\/p\u003e\n\u003cp\u003eA: Check for structural runout or non-4140 metallurgy on the target shaft surface. If the shaft material differs from standard AISI 4140 steel, the scale factor shifts, requiring recalibration of the Proximitor or manual correction factors applied to the TSI monitor configuration.\u003c\/p\u003e\n\u003cp\u003eQ: Can this 0.5-meter probe be connected directly to a 3500 monitor?\u003c\/p\u003e\n\u003cp\u003eA: No. The probe is a passive transducer and must be connected via an appropriate 3300 XL extension cable to a 3300 XL Proximitor Sensor. The total length of the probe plus the extension cable must equal the tuned length of the Proximitor (typically 5.0 meters or 9.0 meters).\u003c\/p\u003e\n\u003cp\u003eQ: Is hot-swapping or disconnect of the probe allowed while the machinery monitor is live?\u003c\/p\u003e\n\u003cp\u003eA: Disconnecting the probe coaxial link while the Proximitor is powered will cause the monitor loop current to saturate, driving the associated monitor channel into a \"Not OK\" status fault condition. This will inhibit trips for that channel but will not damage the hardware.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518823358637,"sku":"330101-00-85-05-01-05","price":112.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330101-00-85-05-01-05-3300-xl-8-mm-probe-dinlqvvatea.jpg?v=1766979620","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-330101-00-85-05-01-05-3300-xl-8-mm-probe-proximity-sensors-3300-xl-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}