{"product_id":"bently-nevada-330101-00-45-10-12-cn-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330101-00-45-10-12-CN 3300 XL 8 mm Proximity Probe","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330101-00-45-10-12-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperates as a dedicated hardware component for non-contacting static and dynamic shaft displacement measurements within 3300 XL Turbomachinery Instrumentation System platforms. The hardware measures high-frequency eddy-current field variations generated by the tip assembly interacting with a rotating conductive target to provide raw radial vibration, shaft position, or speed data.\u003c\/p\u003e\n\u003ch3\u003eTechnical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330101-00-45-10-12-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.32 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.0 x 15.0 x 5.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive Component (Driven by external Proximitor Sensor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThread Parameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8-24 UNF Threaded Barrel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUnthreaded Length Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.0 inches (-00 option)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOverall Case Length Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.5 inches (-45 option)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTotal Cable Length Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 meter (10 option)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnector Type Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature coaxial click-lock with coaxial armor (-12 option)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRegional Compliance Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCCC\/China National Standards (-CN option)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Scale Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) when matched with 3300 XL Proximitor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics Calibration\u003c\/h3\u003e\n\u003cp\u003eThe 8 mm sensing tip relies on strict compliance with factory-calibrated eddy-current probe scaling constraints to output an electrical response slope of 7.87 V\/mm. Mechanical positioning via the threaded casing defines the static air gap, matching the gap voltage validation target of -10 VDC at the linear center point of the transducer system loop. This physical-to-electrical alignment enables continuous parsing of microscopic high-frequency rotor dynamics. Internal impedance optimization across the coaxial path preserves signal integrity and ensures cross-talk suppression when dual probes are configured in orthogonal X-Y arrangements on a single machinery bearing housing.\u003c\/p\u003e\n\u003ch3\u003eComponent Integration\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransducer Unit Package:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eContains the 330101 8 mm probe assembly featuring an armored 1.0-meter integrated cable and click-lock coaxial terminal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeparated Ancillaries:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMatching 3300 XL Proximitor sensors, extension cables, and mounting brackets must be ordered as distinct items to form a complete instrumentation loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistics and Dispatch Criteria\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcessing Interval:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaterial dispatch is scheduled within 2 to 7 days when payment finish sequences are confirmed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConsignment Operators:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTransportation is carried out via international express handlers including DHL, FEDEX, or UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding Protocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAll components are packed in static-shielding, anti-static industrial packaging to prevent latent electrical defect generation during transit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Torque Limits:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInsert the probe thread manually into the mounting port. Torque the primary locknuts to a maximum value of 11.2 N-m (100 in-lb) to prevent structural distortion of the 3\/8-24 UNF threaded barrel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransducer Gap Optimization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnect a digital voltmeter to the Proximitor sensor output loop terminals. Adjust the probe insertion depth relative to the target face until the real-time gap voltage validation reads exactly -10 VDC nominal before securing the jam nut.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCoaxial Connector Grounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eKeep the miniature click-lock connectors completely clean and dry during routing. Insulate the connector joint with fluorocarbon heat-shrink sleeves to prevent grounding against local flexible conduit walls, maintaining cross-talk suppression.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does an installation deviation from the nominal gap voltage validation affect vibration data?\u003c\/p\u003e\n\u003cp\u003eA: Placing the probe tip outside the calibrated linear zone alters the baseline eddy-current probe scaling factor. This cause leads to signal clipping during high-amplitude transient events, resulting in degraded accuracy when tracking high-frequency rotor dynamics.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 1.0-meter armored cable be cut or modified to simplify physical routing?\u003c\/p\u003e\n\u003cp\u003eA: No. Altering the physical length of the integral cable changes the tuned loop capacitance and electrical length parameters. Splicing disrupts the calibrated eddy-current probe scaling matrix, invalidating the system calibration.\u003c\/p\u003e\n\u003cp\u003eQ: What separation distance must be maintained to achieve effective cross-talk suppression?\u003c\/p\u003e\n\u003cp\u003eA: Maintain a minimum center-to-center separation distance of 40 mm between adjacent 8 mm probe tips. Positioning tips closer than this threshold allows their electromagnetic fields to overlap, causing signal beat frequencies that override cross-talk suppression circuits.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518822146221,"sku":"330101-00-45-10-12-CN","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330101-00-45-10-12-cn-3300-xl-8-mm-probe-xrjr14icx4z.jpg?v=1766979577","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-330101-00-45-10-12-cn-3300-xl-8-mm-proximity-probe","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}