{"product_id":"bently-nevada-330101-00-33-10-12-05-non-contacting-proximity-probe","title":"Bently Nevada 330101-00-33-10-12-05 Non-Contacting Proximity Probe","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Bently Nevada 330101-00-33-10-12-05 Proximity Probe executes critical non-contacting shaft displacement and dynamic vibration measurements within heavy turbo-machinery assets. This 8 mm eddy current transducer interfaces seamlessly with the industry-standard Bently Nevada 3500 monitoring platform, generating low-noise voltage signals that drive automated emergency shutdown sequences. It operates with extreme reliability inside severe physical environments, tracking microscopic shaft movements within fluid-film bearings under high-velocity conditions. Control engineers deploy this specialized hardware across steam turbines, industrial gas compressors, and high-pressure process pumps to feed direct data streams into local distributed control networks, eliminating catastrophic mechanical breakdowns and minimizing unplanned production downtime.\u003c\/p\u003e\n\u003ch2\u003ePart Number Coding Matrix\u003c\/h2\u003e\n\u003ch3\u003eThreaded Sleeve Format\u003c\/h3\u003e\n\u003cp\u003eThe 00 suffix codes for a 0 mm unthreaded portion, providing a fully threaded case exterior from tip to base to allow total depth adjustment flexibility within local machine brackets.\u003c\/p\u003e\n\u003ch3\u003eOverall Housing Length\u003c\/h3\u003e\n\u003cp\u003eThe 33 suffix designates a 33 mm overall case depth, providing an intermediate mechanical reach designed to fit standard bearing housings and medium-clearance sensor ports.\u003c\/p\u003e\n\u003ch3\u003eTotal Integrated Cable Length\u003c\/h3\u003e\n\u003cp\u003eThe 10 suffix specifies a 1.0 meter (3.3 feet) overall fluid-resistant cable length, preserving the exact electrical capacitance required to maintain impedance balance with standard extension lines.\u003c\/p\u003e\n\u003ch3\u003eCable Protection and Connector Architecture\u003c\/h3\u003e\n\u003cp\u003eThe 12 suffix delivers a high-flexibility coaxial cable equipped with fluid-tight connector protectors over the miniature click-loc connector, preventing oil mist or chemical moisture from degrading the junction interface.\u003c\/p\u003e\n\u003ch3\u003eAgency Safety Validation\u003c\/h3\u003e\n\u003cp\u003eThe 05 suffix indicates comprehensive hazardous area agency certifications, authorizing immediate installation within highly volatile industrial zones requiring intrinsic safety protection profiles.\u003c\/p\u003e\n\u003ch2\u003ePhysical and Performance Metrics\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter Nomenclature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCertified Engineering Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHS Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90318080\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.16 kg (0.35 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.2 cm x 15.2 cm x 4.6 cm (6.0 in x 6.0 in x 1.8 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical Thread Profile\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFractional 3\/8-24 UNF-2A threads\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Casing Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 303 Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTip Insulation Matrix\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyphenylene sulfide (PPS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eActive Linear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils), beginning at 0.25 mm (10 mils) standoff distance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCalibration Scale Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) paired with 3300 XL Proximitor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature Window\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51°C to +177°C (-60°F to +351°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Ingress Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP68 fully sealed against moisture and hot lubrication fluid submersions\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eField Calibration and Mechanical Layout\u003c\/h2\u003e\n\u003ch3\u003eTarget Gap Voltage Optimization\u003c\/h3\u003e\n\u003cp\u003eField crews must verify the physical gap voltage during mechanical mounting using a calibrated digital voltmeter tapped into the Proximitor Sensor monitor test terminals. Rotate the probe body through the threaded mounting sleeve until the multimeter displays a stable -10.0 VDC value, securing the sensor target face precisely in the middle of its linear calibration window.\u003c\/p\u003e\n\u003ch3\u003eCoaxial Layout Restrictions\u003c\/h3\u003e\n\u003cp\u003eMaintain a strict minimum cable bend radius of 25.4 mm (1.0 inch) across all physical routing runs. Sharp pinching or rapid kinking breaks the internal silver-plated copper-clad steel core wire, inducing stray capacitance that destroys high-frequency sensor readings and corrupts machine safety loops.\u003c\/p\u003e\n\u003ch3\u003eFloating Shield Infrastructure\u003c\/h3\u003e\n\u003cp\u003eKeep the outer coaxial connector shield completely floating and isolated from the machinery chassis or local metal junction enclosures. Ground the transmission loop exclusively at the main instrumentation rack common chassis bus bar to clear out stray ground loop distortion paths.\u003c\/p\u003e\n\u003ch2\u003eEnvironmental Resilience and DCS Integration\u003c\/h2\u003e\n\u003ch3\u003eThermal Coefficient Drift Mitigation\u003c\/h3\u003e\n\u003cp\u003eThe specialized chemically inert polyphenylene sulfide tip preserves its precise geometric dimensions across intense thermal transitions, preventing measurement drift or scale factor shifts during critical turbine startup and shutdown procedures.\u003c\/p\u003e\n\u003ch3\u003eDistributed Control Architecture Sync\u003c\/h3\u003e\n\u003cp\u003eThis sensor transmits low-impedance analog waveforms directly into the Bently Nevada 3500 monitoring system. The host monitor platform converts the analog metrics and broadcasts registers via Modbus TCP or OPC UA to central plant DCS environments like Honeywell Experion PKS, enabling real-time asset optimization and enterprise-level machine analytics.\u003c\/p\u003e\n\u003ch2\u003eOrdering and Kit Contents\u003c\/h2\u003e\n\u003cp\u003e(1) One authentic Bently Nevada 330101-00-33-10-12-05 Proximity Probe with an attached 1-meter oil-resistant cable leash\u003c\/p\u003e\n\u003cp\u003e(2) Two matching stainless steel locknuts to provide permanent, vibration-resistant positioning locks inside the bracket\u003c\/p\u003e\n\u003cp\u003e(3) One specialized silicone connector protector boot to hermetically seal the click-loc extension cable junction\u003c\/p\u003e\n\u003cp\u003e(4) Complete factory verification sheets documenting individual probe calibration linearity curves and scale factor data\u003c\/p\u003e\n\u003ch2\u003eShipping Operations and Packing Guardrails\u003c\/h2\u003e\n\u003ch3\u003eGlobal Distribution Timelines\u003c\/h3\u003e\n\u003cp\u003eOur logistics warehouse completes order dispatches within 2-7 days when payment finish verification steps settle. We route all shipments through high-priority air express providers including DHL, FedEx, or UPS to guarantee rapid global delivery tracking.\u003c\/p\u003e\n\u003ch3\u003eSpecialized Structural Buffer Packaging\u003c\/h3\u003e\n\u003cp\u003eWe seal each proximity probe within heavy-duty, moisture-barrier anti-static industrial packaging enclosures. This multi-layered wrap shields the sensitive high-frequency eddy-current electronics from sudden static discharge fields and mechanical shock impacts during international transit.\u003c\/p\u003e\n\u003ch2\u003eTechnical Field Questions\u003c\/h2\u003e\n\u003cp\u003eQ1: What mechanical design differentiates the 330101 model from the 330104 model?\u003c\/p\u003e\n\u003cp\u003eA1: The 330101 model utilizes standard fractional 3\/8-24 UNF threads across the probe case, whereas the 330104 model implements metric M10 x 1 threads, tailoring it for European or international machinery configurations.\u003c\/p\u003e\n\u003cp\u003eQ2: What is the specific operational advantage of the 12 suffix option?\u003c\/p\u003e\n\u003cp\u003eA2: The \"12\" option indicates that the probe comes factory-equipped with specialized fluid-tight connector protectors pre-installed on the cable, providing immediate environmental isolation against moisture, cutting fluids, and oil vapor without requiring field-applied tape.\u003c\/p\u003e\n\u003cp\u003eQ3: Which payment structures do you authorize for urgent business orders?\u003c\/p\u003e\n\u003cp\u003eA3: We accept direct international corporate wire transfers (T\/T), verified proforma business credit accounts, and major secure global business-to-business transaction networks.\u003c\/p\u003e\n\u003cp\u003eQ4: Can I cut or shorten the integrated 1.0-meter cable during field installation if it is too long for the junction box?\u003c\/p\u003e\n\u003cp\u003eA4: Never cut or splice proximity probe cables. The 1.0-meter length forms an essential part of the high-frequency tuned RF circuit; changing the length alters the total capacitance and destroys calibration accuracy, leading to false vibration readings in your DCS system.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518877524141,"sku":"330101-00-33-10-12-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330101-00-33-10-12-05-3300-xl-8-mm-proximity-probes-bsrjtb1vokw.jpg?v=1766980797","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-330101-00-33-10-12-05-non-contacting-proximity-probe","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}