{"product_id":"bently-nevada-330101-00-24-05-02-00-3300-xl-8-mm-proximity-series","title":"Bently Nevada 330101-00-24-05-02-00 3300 XL 8 mm Proximity Series","description":"\u003cp\u003eConfigured for non-contacting shaft displacement and vibration measurements in machinery protection systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330101-00-24-05-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330101\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330101\u003c\/strong\u003e: 3300 XL 8 mm Proximity Probe, 3\/8-24 UNF thread, without armor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Unthreaded Length option (0.0 in).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e24\u003c\/strong\u003e: Overall Case Length option (2.4 in).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: Total Length option (0.5 meter \/ 1.6 feet).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Connector option (Miniature coaxial ClickLoc connector, standard cable).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Agency Approval option (No hazardous area approvals required).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330101-00-24-05-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.12 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.0 cm x 15.0 cm x 4.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSourced via paired 3300 XL Proximitor Sensor (Typically -24 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.0 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThread Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8-24 UNF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils), spanning from 0.25 mm to 2.25 mm (10 to 90 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) when properly paired with 3300 XL Proximitor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL 8 mm probe operates via eddy-current probe scaling calibrated to a standard AISI 4140 steel target. Misalignment or deviation from this target material alters the eddy-current field interaction, requiring recalibration of the scale factor. To accurately trace fluid-film bearing states and real-time rotor dynamics, gap voltage validation (-10 VDC targets) must be verified at the geometric midpoint of the linear range. This static voltage window prevents signal clipping during high-amplitude dynamic vibration cycles. Internal design constraints minimize side-viewing fields, establishing cross-talk suppression when multiple probes are oriented in orthogonal X-Y configurations or tight axial arrays.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does a mismatch in total system electrical length affect performance?\u003c\/p\u003e\n\u003cp\u003eA: The 0.5-meter probe must be connected to an appropriate 3300 XL extension cable to achieve a total system length of 5.0 meters or 9.0 meters. Mismatching the total electrical length introduces severe scale factor non-linearity and errors in the -10 VDC gap voltage baseline.\u003c\/p\u003e\n\u003cp\u003eQ: Can this probe be swapped while the monitoring system is live?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The probe is a passive inductive device and supports hot-swapping at the coaxial interface without disrupting power to the 3500 rack or Proximitor Sensor, provided standard safety procedures for local field loops are followed.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Torque Constraints\u003c\/strong\u003e: Do not exceed the maximum torque specification of 13.6 N-m (120 in-lb) when tightening the 3\/8-24 UNF mounting nuts. Over-tightening causes case distortion and internal element failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Integrity\u003c\/strong\u003e: Hand-tighten the ClickLoc coaxial connector until an explicit tactile click is verified. Do not use pliers or metallic tools, which can deform the miniature coaxial interface and induce signal noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClearance Profile\u003c\/strong\u003e: Maintain a minimum counterbore clearance radius of 9.5 mm (0.38 in) around the 8.0 mm probe tip to prevent adjacent structural metal from causing target errors or scale factor dampening.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation and Grounding\u003c\/strong\u003e: Ensure the coaxial connector junction is insulated using silicone self-bonding tape or connector protectors. The outer shield must remain isolated from structural ground until it terminates at the Proximitor Sensor terminal strip.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518870839469,"sku":"330101-00-24-05-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330101-00-24-05-02-00-3300-xl-8-mm-proximity-probe-cwpjzmpqcd1.jpg?v=1766980672","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-330101-00-24-05-02-00-3300-xl-8-mm-proximity-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}