{"product_id":"bently-nevada-330101-00-18-10-12-05-eddy-current-linear-displacement-probe","title":"Bently Nevada 330101-00-18-10-12-05 Eddy Current Linear Displacement Probe","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Bently Nevada 330101-00-18-10-12-05 Proximity Probe serves as a foundational data extraction asset for high-speed industrial machinery monitoring networks. This 8 mm non-contacting sensor directly monitors dynamic shaft vibration, axial position drift, and structural thermal expansion within fluid-film bearings. It translates subtle physical micro-movements into linear voltage changes, providing essential raw inputs to the Bently Nevada 3500 monitoring platform. Reliability under aggressive environmental conditions makes this sensor a core necessity for steam turbine supervisory instrumentation, petrochemical turbo-compressors, and critical process water pumps. Control engineers deploy this robust transducer to feed decisive, low-noise signals into emergency trip circuits, preventing catastrophic component failures and safeguarding integrated distributed control architectures from costly production halts.\u003c\/p\u003e\n\u003ch2\u003eModel Structure and Option Parameter Mapping\u003c\/h2\u003e\n\u003ch3\u003eUnthreaded Sleeve Selection\u003c\/h3\u003e\n\u003cp\u003eThe 00 suffix establishes a 0 mm unthreaded case profile, providing a continuous fractional thread configuration that maximizes depth fine-tuning options within standard mounting blocks.\u003c\/p\u003e\n\u003ch3\u003eTotal Case Depth Profile\u003c\/h3\u003e\n\u003cp\u003eThe 18 suffix designates an overall case length of 18 mm, optimizing the physical reach for low-clearance bearing housings and compact radial sensor ports.\u003c\/p\u003e\n\u003ch3\u003eTotal Cable Span Parameter\u003c\/h3\u003e\n\u003cp\u003eThe 10 suffix sets a 1.0 meter (3.3 feet) integrated cable span, maintaining the tight electrical capacitance criteria required to prevent signal distortion when paired with extension cables.\u003c\/p\u003e\n\u003ch3\u003eCoaxial Protection Matrix\u003c\/h3\u003e\n\u003cp\u003eThe 12 suffix specifies a high-flexibility fluid-resistant coaxial cable variant terminated with a miniature click-loc connector and equipped with fluid-tight connector protectors, ensuring isolation from internal machine mist.\u003c\/p\u003e\n\u003ch3\u003eIntrinsic Safety Certificate Rating\u003c\/h3\u003e\n\u003cp\u003eThe final 05 suffix validates compliance with multiple international explosion-proof agency standards, certifying the system for continuous use inside Class I, Division 1 and Zone 0 hazardous refinery environments.\u003c\/p\u003e\n\u003ch2\u003ePhysical and Mechanical Characteristics\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical and Operational Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eVerified Engineering Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHS Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90318080\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.16 kg (0.35 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.5 cm x 15.5 cm x 4.8 cm (6.1 in x 6.1 in) x 1.9 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThread Core Specification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFractional 3\/8-24 UNF-2A threads\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStructural Material Matrix\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 303 Stainless Steel housing shell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSensor Tip Compound\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyphenylene sulfide (PPS) hermetic insulation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eActive Measurement Window\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils), beginning at 0.25 mm (10 mils) standoff distance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Scale Factor Sensitivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) with a matching 3300 XL Proximitor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThermal Operation Bandwidth\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51°C to +177°C (-60°F to +351°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Ingress Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP68 rating, completely submersible against lubrication fluids\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eOn-Site Deployment Rules\u003c\/h2\u003e\n\u003ch3\u003ePhysical Gap Adjustments via Voltage\u003c\/h3\u003e\n\u003cp\u003eField technicians must adjust the spatial gap voltage during mechanical mounting by tapping into the Proximitor Sensor monitor test terminals. Rotate the probe body through the mounting sleeve until the multimeter displays -10.0 VDC, centering the target face precisely within the linear calibration zone.\u003c\/p\u003e\n\u003ch3\u003eCable Geometry Enforcement\u003c\/h3\u003e\n\u003cp\u003eMaintain a strict minimum cable bend radius of 25.4 mm (1.0 inch) across all routing runs. Forcing sharp bends breaks the inner copper-clad steel core, causing high-frequency signal dropouts that can trigger false asset trips.\u003c\/p\u003e\n\u003ch3\u003eFloating Shield Protocol\u003c\/h3\u003e\n\u003cp\u003eIsolate the outer coaxial shield from local metallic junction enclosures and machine frames. Ground the signal loop solely at the instrumentation rack common chassis bus bar to clear out stray electromagnetic interference paths.\u003c\/p\u003e\n\u003ch2\u003eEnvironmental Stress and Architecture Matching\u003c\/h2\u003e\n\u003ch3\u003eThermal Expansion Invariance\u003c\/h3\u003e\n\u003cp\u003eThe advanced chemical-resistant polyphenylene sulfide tip avoids geometric shifts during sharp industrial thermal transitions, eliminating measurement drift while monitoring turbine startup cycles.\u003c\/p\u003e\n\u003ch3\u003eDCS Network Compatibility\u003c\/h3\u003e\n\u003cp\u003eThis probe streams continuous low-impedance analog waveforms to local 3500 series acquisition hardware. The host monitor platform converts the analog metrics and broadcasts registers via Modbus TCP or OPC UA to central plant DCS environments like Honeywell Experion PKS, enabling real-time remote diagnostics.\u003c\/p\u003e\n\u003ch2\u003eOrdering and Kit Contents\u003c\/h2\u003e\n\u003cp\u003e(1) One authentic Bently Nevada 330101-00-18-10-12-05 Proximity Probe with an integrated 1-meter oil-resistant cable\u003c\/p\u003e\n\u003cp\u003e(2) Two matching stainless steel locknuts to lock in the target mechanical gap under extreme casing vibration\u003c\/p\u003e\n\u003cp\u003e(3) One specialized silicone connector boot designed to seal out moisture at the click-loc extension cable junction\u003c\/p\u003e\n\u003cp\u003e(4) Complete factory verification sheets documenting the individual probe calibration linearity and scale factor accuracy\u003c\/p\u003e\n\u003ch2\u003eShipping Operations and Packing Guardrails\u003c\/h2\u003e\n\u003ch3\u003eGlobal Distribution Timelines\u003c\/h3\u003e\n\u003cp\u003eOur logistics warehouse completes order dispatches within 2-7 days when payment finish verification steps settle. We process all shipments through high-priority air express providers including DHL, FedEx, or UPS for secure tracking.\u003c\/p\u003e\n\u003ch3\u003eSpecialized Structural Buffer Packaging\u003c\/h3\u003e\n\u003cp\u003eWe seal each proximity probe within heavy-duty, anti-static industrial packaging. This multi-layered wrap shields the sensitive high-frequency eddy-current electronics from sudden static discharge fields and mechanical shocks during global transit.\u003c\/p\u003e\n\u003ch2\u003eField Maintenance FAQs\u003c\/h2\u003e\n\u003cp\u003eQ1: What mechanical design differentiates the 330101 series from the 330103 series?\u003c\/p\u003e\n\u003cp\u003eA1: The 330101 series utilizes standard fractional 3\/8-24 UNF threads across the probe case, whereas the 330103 series implements fractional 3\/8-24 UNF reverse-mount geometries tailored for internal bracket installations.\u003c\/p\u003e\n\u003cp\u003eQ2: How do I decode the specific 12-05 suffix options for this hardware?\u003c\/p\u003e\n\u003cp\u003eA2: The \"12\" option indicates a specialized fluid-tight option with integrated connector protectors over the standard click-loc connector. The \"05\" suffix denotes global hazardous area approvals for safe deployment in volatile zones.\u003c\/p\u003e\n\u003cp\u003eQ3: What processes do you support for international corporate payment clearance?\u003c\/p\u003e\n\u003cp\u003eA3: We accept direct corporate wire transfers via Telegraphic Transfer (T\/T), pre-approved commercial proforma credit terms, and major secure global business-to-business transaction services.\u003c\/p\u003e\n\u003cp\u003eQ4: Can I splice or alter the length of this integrated 1.0-meter cable during field routing?\u003c\/p\u003e\n\u003cp\u003eA4: Never cut or splice proximity probe cables. The 1.0-meter length is a tuned electrical element containing precise inductance and capacitance; modifying the length destroys system calibration linearity and renders the output data invalid.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518877556909,"sku":"330101-00-18-10-12-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330101-00-18-10-12-05-3300-xl-8-mm-probes-as0j43bvper.jpg?v=1766980797","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-330101-00-18-10-12-05-eddy-current-linear-displacement-probe","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}