{"product_id":"bently-nevada-330101-00-17-10-02-00-proximity-probe-3300-xl-8-mm-series","title":"Bently Nevada 330101-00-17-10-02-00 Proximity Probe 3300 XL 8 mm Series","description":"\u003cp\u003eConfigured for non-contact shaft vibration and radial displacement measurement in 3300 XL monitoring systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330101-00-17-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330101\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct eddy-current transducer operation through matched probe, extension cable, and Proximitor assemblies. The probe converts shaft position variation into proportional electrical output for machinery protection systems.\u003c\/p\u003e\n\u003ch3\u003eOrdering Code Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eCode Segment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330101\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eStandard agency approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003ctd\u003e1.7 m system length configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003eStandard cable and connector option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eMetric threaded probe body\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eStandard product revision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical and Electrical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330101-00-17-10-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProximity Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Diameter\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Principle\u003c\/td\u003e\n\u003ctd\u003eEddy-current non-contact sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring Function\u003c\/td\u003e\n\u003ctd\u003eShaft vibration and position measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Systems\u003c\/td\u003e\n\u003ctd\u003e3300 XL Transducer Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Body Material\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Thread\u003c\/td\u003e\n\u003ctd\u003eMetric threaded body\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eClickLoc miniature coaxial connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eIntegral low-noise coaxial cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShield Construction\u003c\/td\u003e\n\u003ctd\u003eFull braided shield coverage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatic Gap Voltage\u003c\/td\u003e\n\u003ctd\u003eApproximately -10 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Measurement Range\u003c\/td\u003e\n\u003ctd\u003eCompatible with 3300 XL calibrated system range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003eRotor dynamic vibration monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Output Path\u003c\/td\u003e\n\u003ctd\u003eThrough associated Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Cable Length\u003c\/td\u003e\n\u003ctd\u003e1.7 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial rotating machinery environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSupplied through Proximitor interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003eApproximately 25 cm x 18 cm x 4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Scaling Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL transducer system operates using calibrated eddy-current interaction between the probe tip and conductive shaft surfaces. System sensitivity depends on matched electrical characteristics between the probe, extension cable, and Proximitor Sensor assembly.\u003c\/p\u003e\n\u003cp\u003eGap voltage verification is commonly performed during commissioning. A nominal static target near -10 VDC positions the probe within the calibrated linear operating region. Excessive probe extension or improper bracket rigidity can alter signal stability and phase response.\u003c\/p\u003e\n\u003cp\u003eSignal routing should avoid parallel installation with motor feeder cables, variable-frequency drive outputs, and switching power conductors. Electromagnetic coupling between adjacent transducer cables may introduce cross-talk and waveform distortion.\u003c\/p\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003eQ: Can the probe operate without a matching Proximitor Sensor?\u003cbr\u003eA: No. The probe requires a compatible Proximitor Sensor assembly for calibrated signal conditioning and displacement output generation.\u003c\/p\u003e\n\u003cp\u003eQ: Is field shortening of the coaxial cable permitted?\u003cbr\u003eA: No. Cable modification changes impedance and affects transducer calibration characteristics.\u003c\/p\u003e\n\u003cp\u003eQ: What is the purpose of the -10 VDC gap reference?\u003cbr\u003eA: The gap voltage establishes the probe within the linear operating range required for accurate shaft displacement measurement.\u003c\/p\u003e\n\u003cp\u003eQ: Can the probe assembly be installed near VFD output cables?\u003cbr\u003eA: Separation from high-energy switching conductors is recommended to minimize electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eQ: Does the probe require dual-end shield grounding?\u003cbr\u003eA: Shield grounding is typically implemented at one instrumentation reference point to reduce ground loop currents.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eVerify mounting bracket rigidity before final probe positioning. Mechanical looseness at the bracket interface can generate false vibration readings during machine operation.\u003c\/p\u003e\n\u003cp\u003eAdvance the probe gradually toward the shaft surface while monitoring static gap voltage through the associated monitor or Proximitor output. Sudden voltage fluctuation may indicate shaft runout, contamination, or improper alignment.\u003c\/p\u003e\n\u003cp\u003eAvoid sharp cable bend radii near connector terminations. Connector locking hardware should remain fully secured to maintain shielding continuity and signal integrity.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330101-00-17-10-02-00 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegral coaxial cable assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector protection hardware\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFactory identification labeling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLogistics and Dispatch\u003c\/h2\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish. Shipment is arranged through DHL, FedEx, or UPS using anti-static industrial packaging with reinforced internal cushioning for vibration transducer protection during international transport.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518834041005,"sku":"330101-00-17-10-02-00","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330101-00-17-10-02-00-3300-xl-8-mm-proximity-probes-fzyenuj13dw.jpg?v=1766979960","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-330101-00-17-10-02-00-proximity-probe-3300-xl-8-mm-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}