{"product_id":"bently-nevada-330101-00-11-10-02-05-proximity-probe-3300-xl-series","title":"Bently Nevada 330101-00-11-10-02-05 Proximity Probe 3300 XL Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330101-00-11-10-02-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330101\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe utilized to execute non-contacting shaft displacement and vibration measurements across Turbine Supervisory Instrumentation (TSI) platforms. The hardware establishes a high-frequency radio frequency (RF) eddy-current circuit at the 8 mm tip, transforming the physical gap variations between the probe face and the observed target area into linear electrical metrics processed by a standard Proximitor driver module.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330101\u003c\/strong\u003e: 3300 XL 8 mm Proximity Probe with 3\/8-24 UNF thread and integral coaxial armor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-00\u003c\/strong\u003e: Unthreaded length option specified as 0.0 inches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-11\u003c\/strong\u003e: Overall case length option specified as 1.1 inches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-10\u003c\/strong\u003e: Total system length option specified as 1.0 meter (3.3 feet).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-02\u003c\/strong\u003e: Miniature coaxial ClickLoc connector with connector protector included.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-05\u003c\/strong\u003e: Multiple hazardous area approvals (ATEX, IECEx, CSA certifications).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330101-00-11-10-02-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.26 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e21.5 cm x 16.0 cm x 5.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive device (excited via Proximitor circuit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTip Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils), beginning at a 0.25 mm (10 mils) baseline gap\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Scale Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Armor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFlexible stainless steel conduit covering\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Cross-Talk Suppression\u003c\/h3\u003e\n\u003cp\u003eOperation of the eddy-current sensor relies on specific material-dependent calibration properties. Standard eddy-current probe scaling is fixed at 7.87 V\/mm against AISI 4140 steel targets; alternative shaft alloys distort the inductive impedance conversion and induce scaling faults. Cross-talk suppression becomes essential when multiple probes reside within a singular bearing assembly. The spatial positioning of adjacent 8 mm units must be maintained outside overlapping magnetic fields, while the isolated physical casing design isolates the active sensing coil from high-frequency structural noise and grounding plane variations in the rotor assembly.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is this proximity probe module rated for live hot-swap execution during machinery operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The passive probe assembly can be unscrewed or disconnected from its matched extension cable while the associated 3500 rack or Proximitor driver remains powered without inducing electrical overload to the loop components.\u003c\/p\u003e\n\u003cp\u003eQ: How is the physical midpoint calibration verified on-site during installation?\u003c\/p\u003e\n\u003cp\u003eA: Gap voltage validation requires monitoring the analog loop via a digital voltmeter. The probe is threaded into the machine casing until the output indexes to a target value of -10 VDC targets, which indicates the geometric midpoint of the linear tracking field.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 1.0 meter armored cable be cut down or modified during a field retrofit?\u003c\/p\u003e\n\u003cp\u003eA: No. The physical length and configuration of the armored coaxial cable provide a specific matched capacitance and inductance required for the RF oscillator loop. Truncation or splicing alters the impedance network and destroys calibration tracking accuracy.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRadial Clearance Bounds\u003c\/strong\u003e: Maintain an unobstructed cylindrical envelope of at least 30 mm diameter around the 8 mm tip to avoid signal degradation from adjacent structural framework.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Locknut Torque\u003c\/strong\u003e: Secure the 3\/8-24 UNF threaded casing to the machinery bracket using the matching jam nuts, limiting structural installation torque to a maximum value of 11.2 N-m (100 in-lb).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Interface Protection\u003c\/strong\u003e: Ensure the ClickLoc coaxial terminal connector protector is completely seated over the extension cable joint to prevent moisture, lubricants, or particulate bypass from entering the RF path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShield Grounding Boundary\u003c\/strong\u003e: Isolate the armored exterior casing from local field ground potentials. Route the internal coaxial shield continuously to the instrument common terminal on the monitor rack chassis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandard Procurement Kit Inventory\u003c\/h3\u003e\n\u003cp\u003eThe packaging manifest defines the following standard kit items:\u003c\/p\u003e\n\u003cp\u003e(1) Bently Nevada 330101-00-11-10-02-05 Armored 8 mm Proximity Probe\u003c\/p\u003e\n\u003cp\u003e(2) Dual hex jam nuts and single split lockwasher\u003c\/p\u003e\n\u003cp\u003e(3) Removable rubber thread-engagement shield\u003c\/p\u003e\n\u003cp\u003e(4) Certified factory validation document displaying linear range test traces\u003c\/p\u003e\n\u003ch3\u003eSupply Chain and Transport Provisions\u003c\/h3\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish through automated express channels such as DHL, FEDEX, or UPS. Logistics protocols require heavy-duty, anti-static industrial packaging layers to intercept mechanical friction anomalies and prevent electrostatic damage to the internal induction coil terminations while in transit.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518867103917,"sku":"330101-00-11-10-02-05","price":59.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330101-00-11-10-02-05-proximity-probe-ypwkwdsvgnn.jpg?v=1766980558","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-330101-00-11-10-02-05-proximity-probe-3300-xl-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}