{"product_id":"bently-nevada-31000-30-05-15-31-03-02-proximity-probe-housing-31000-series","title":"Bently Nevada 31000-30-05-15-31-03-02 Proximity Probe Housing 31000 Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 31000-30-05-15-31-03-02\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e31000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe Housing, operates as a dedicated hardware component for external probe mounting and cable isolation within Bently Nevada TSI monitoring systems. The housing assembly provides mechanical positioning support, conduit routing, and environmental sealing for eddy-current proximity transducer installations.\u003c\/p\u003e\n\u003ch3\u003eConfiguration Identification\u003c\/h3\u003e\n\u003cp\u003eThe supplied model represents a fixed 31000 Series housing configuration used with Bently Nevada proximity probe systems. No independent suffix matrix or field-selectable ordering breakdown was provided in the available technical data.\u003c\/p\u003e\n\u003ch3\u003eMechanical and Installation Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e31000-30-05-15-31-03-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProximity Probe Housings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e31000 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Probe Type\u003c\/td\u003e\n\u003ctd\u003eEddy-current proximity probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Size Compatibility\u003c\/td\u003e\n\u003ctd\u003e5 mm and 8 mm probe systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eExternal threaded mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Interface\u003c\/td\u003e\n\u003ctd\u003eIndustrial threaded housing connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Routing Method\u003c\/td\u003e\n\u003ctd\u003eInternal conduit-style cable passage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eOil-resistant sealed housing body\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Function\u003c\/td\u003e\n\u003ctd\u003eProbe positioning and cable isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Adjustment Method\u003c\/td\u003e\n\u003ctd\u003eAxial mechanical positioning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShield Ground Continuity\u003c\/td\u003e\n\u003ctd\u003eHousing-assisted grounding path\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Interface\u003c\/td\u003e\n\u003ctd\u003eBently Nevada TSI monitoring systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Area\u003c\/td\u003e\n\u003ctd\u003eTurbines, compressors, motors, and pumps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive mechanical assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Interface\u003c\/td\u003e\n\u003ctd\u003eThread-sealed industrial mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 1.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003eApproximately 32 x 16 x 11 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Compatibility\u003c\/td\u003e\n\u003ctd\u003eExtension cable and proximitor routing support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eGap Voltage Stability and Cross-Talk Control\u003c\/h3\u003e\n\u003cp\u003eThe housing assembly maintains fixed mechanical alignment between the eddy-current probe tip and conductive shaft target surface. Probe positioning accuracy directly affects linearity response, shaft displacement scaling, and waveform repeatability during rotor movement.\u003c\/p\u003e\n\u003cp\u003eGap voltage validation is commonly performed during commissioning to verify correct probe operating position. Bently Nevada proximity systems typically reference DC bias targets near -10 VDC depending on transducer configuration and extension cable combination.\u003c\/p\u003e\n\u003cp\u003eInternal cable routing practices inside the housing assembly assist in reducing electromagnetic coupling between adjacent vibration channels. Shield continuity and conduit grounding reduce cross-talk propagation generated by nearby motor feeders and switching devices.\u003c\/p\u003e\n\u003ch3\u003eTechnical Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the housing include a proximitor sensor assembly?\u003cbr\u003eA: No. The housing functions as a mechanical support and environmental isolation structure for separately installed probe system components.\u003c\/p\u003e\n\u003cp\u003eQ: Can the housing support conduit cable routing?\u003cbr\u003eA: Yes. The assembly supports protected routing of extension cables through industrial conduit-style interfaces.\u003c\/p\u003e\n\u003cp\u003eQ: Why is probe gap verification required after installation?\u003cbr\u003eA: Probe gap distance directly affects eddy-current scaling accuracy and DC bias operating range.\u003c\/p\u003e\n\u003cp\u003eQ: Does housing rigidity influence rotor vibration readings?\u003cbr\u003eA: Yes. Mechanical looseness or mounting instability may introduce vibration measurement variation and signal distortion.\u003c\/p\u003e\n\u003cp\u003eQ: Are shield grounding practices required for installation?\u003cbr\u003eA: Yes. Shield continuity and single-point grounding practices assist in reducing electrical noise and signal interference.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eVerify threaded mounting engagement before tightening the housing assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain probe cable separation from high-current conductors and VFD output cables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspect sealing surfaces before conduit installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvoid excessive cable bending inside the housing conduit path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm probe tip alignment before final locknut tightening.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse anti-static handling procedures during probe and extension cable installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePerform final gap voltage verification after mechanical installation is complete.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain shield continuity between the housing assembly and cabinet grounding system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e31000 Series Proximity Probe Housing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial anti-static protective packaging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical cushioning material\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOptional accessories supplied separately:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEddy-current proximity probes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExtension cables\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProximitor sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting adapters and conduit fittings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eShipping Information\u003c\/h2\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish. Shipment available through DHL, FedEx, or UPS using anti-static industrial export packaging with reinforced cushioning protection for vibration monitoring hardware and precision mechanical assemblies.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518834139309,"sku":"31000-30-05-15-31-03-02","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-31000-30-05-15-31-03-02-proximity-probe-housingassemblies-lzmrsqj2xmn.jpg?v=1766979963","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-31000-30-05-15-31-03-02-proximity-probe-housing-31000-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}