{"product_id":"bently-nevada-21000-16-05-00-076-04-02-proximity-probe-housing-assemblies-21000-series","title":"Bently Nevada 21000-16-05-00-076-04-02 Proximity Probe Housing Assemblies 21000 Series","description":"\u003cp\u003eConfigured for external eddy-current probe mounting and cable isolation in Bently Nevada TSI monitoring systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 21000-16-05-00-076-04-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e21000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe Housing Assembly) provides direct mechanical support and conduit-based cable routing. The assembly maintains probe positioning stability while isolating extension cable interfaces from contamination, oil ingress, and conductive debris inside rotating machinery environments.\u003c\/p\u003e\n\u003ch3\u003eModel Reference Notes\u003c\/h3\u003e\n\u003cp\u003eThe supplied part number represents a fixed Bently Nevada 21000 Series housing configuration. The provided documentation does not include independent suffix decoding or field-selectable matrix segmentation.\u003c\/p\u003e\n\u003ch3\u003eMechanical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e21000-16-05-00-076-04-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProximity Probe Housing Assemblies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e21000 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eStainless steel industrial housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Compatibility\u003c\/td\u003e\n\u003ctd\u003e5 mm and 8 mm eddy-current proximity probe systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eExternal threaded mechanical mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Entry Type\u003c\/td\u003e\n\u003ctd\u003eConduit-style protected cable routing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eOil-resistant and contamination-isolated housing structure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Installation Interface\u003c\/td\u003e\n\u003ctd\u003eAdjustable axial probe positioning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtension Cable Support\u003c\/td\u003e\n\u003ctd\u003eIntegrated cable routing chamber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding Method\u003c\/td\u003e\n\u003ctd\u003eShield continuity through housing body\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Interface\u003c\/td\u003e\n\u003ctd\u003eTSI vibration and shaft monitoring systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Function\u003c\/td\u003e\n\u003ctd\u003eProbe alignment and environmental isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive mechanical assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Configuration\u003c\/td\u003e\n\u003ctd\u003eContinuous industrial monitoring duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003eApproximately 30 x 15 x 10 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Sealing Method\u003c\/td\u003e\n\u003ctd\u003eThreaded sealing interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Area\u003c\/td\u003e\n\u003ctd\u003eTurbine, compressor, and rotating machinery casing assemblies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Support\u003c\/td\u003e\n\u003ctd\u003eEddy-current probe displacement signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eGap Voltage and Rotor Dynamics Considerations\u003c\/h3\u003e\n\u003cp\u003eThe housing assembly maintains fixed mechanical positioning for eddy-current probe systems operating within shaft vibration and rotor displacement measurement loops. Probe target alignment directly influences scale factor consistency and waveform stability during rotor movement.\u003c\/p\u003e\n\u003cp\u003eGap voltage validation is typically performed during commissioning to verify probe linear operating range. Bently Nevada proximity systems commonly target DC bias values near -10 VDC depending on probe extension length and transducer calibration combinations.\u003c\/p\u003e\n\u003cp\u003eMechanical rigidity inside the housing assembly reduces positional drift generated by thermal casing expansion and vibration-induced movement. Proper conduit grounding and cable shielding practices assist in suppressing signal cross-talk between adjacent monitoring channels.\u003c\/p\u003e\n\u003ch3\u003eTechnical Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the housing assembly include an integrated proximitor sensor?\u003cbr\u003eA: No. The assembly functions as a mechanical installation structure for externally connected probe and proximitor components.\u003c\/p\u003e\n\u003cp\u003eQ: Can the housing be mounted directly on turbine bearing casings?\u003cbr\u003eA: Yes. The assembly is designed for threaded installation on machinery casings supporting proximity probe measurement points.\u003c\/p\u003e\n\u003cp\u003eQ: Why is probe gap adjustment required after installation?\u003cbr\u003eA: Eddy-current probe output scaling depends on probe-to-target spacing and conductive target geometry.\u003c\/p\u003e\n\u003cp\u003eQ: Does the assembly affect vibration signal quality?\u003cbr\u003eA: Mechanical stability, grounding continuity, and cable routing practices influence low-level probe signal integrity.\u003c\/p\u003e\n\u003cp\u003eQ: Are conduit grounding practices required during installation?\u003cbr\u003eA: Yes. Shield continuity and single-point grounding practices should follow TSI installation procedures to reduce electrical noise coupling.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eVerify threaded engagement depth before tightening the housing assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain separation between probe cables and motor power conductors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvoid excessive cable bending inside conduit routing sections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm probe tip alignment before final locknut tightening.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspect conduit sealing surfaces for contamination before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse anti-static handling procedures during probe cable connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePerform final gap voltage verification after mechanical tightening is completed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain shield grounding continuity between the housing body and monitoring cabinet earth point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e21000 Series Proximity Probe Housing Assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial anti-static protective packaging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical cushioning material for transport protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOptional items supplied separately:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEddy-current proximity probes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProbe extension cables\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProximitor sensor assemblies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting adapters and conduit fittings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping \u0026amp; Packaging\u003c\/h3\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish. Shipment available through DHL, FedEx, or UPS using anti-static industrial export packaging with reinforced internal cushioning for vibration monitoring assemblies and precision mechanical components.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518835482797,"sku":"21000-16-05-00-076-04-02","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-21000-16-05-00-076-04-02-proximity-probe-housingassemblies-et5e3g1h5n1.jpg?v=1766980013","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-21000-16-05-00-076-04-02-proximity-probe-housing-assemblies-21000-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}