{"product_id":"bently-nevada-16710-99-interconnect-cable","title":"Bently Nevada 16710-99 Interconnect Cable","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 16710-99\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16710\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInterconnect Cable, operates as a dedicated hardware component for transmitting raw high-frequency electrical signals within\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTurbinery Supervisory Instrumentation (TSI) transducer loops.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16710-99\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.0 cm x 25.0 cm x 6.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNone (Passive coaxial electrical conductor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCoaxial, low-capacitance shielded network link\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnector Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature coaxial male-to-female interface ports\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInsulation Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFluorinated Ethylene Propylene (FEP) outer jacket\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eImpedance Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 Ohm nominal RF characteristic impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Gap Voltage Validation\u003c\/h3\u003e\n\u003cp\u003eThe 16710-99 electrical link serves as a core matching component within the proximity transducer circuit. Because the system utilizes radio frequency resonance to generate eddy-current probe scaling, any alteration in loop capacitance or length changes the voltage output curve. During system calibration updates, technicians perform gap voltage validation to ensure accurate tracking of dynamic rotor dynamics.\u003c\/p\u003e\n\u003cp\u003eAchieving a precise -10 VDC targets reading across the linear midpoint requires a continuous, low-attenuation electrical path from the probe head to the processing driver. The structural configuration of this coaxial link incorporates tight shielding tolerances to maintain cross-talk suppression when routed alongside parallel sensor channels near dense bearing housings.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the -99 suffix designate a specific pre-cut mechanical length for this interconnect cable?\u003c\/p\u003e\n\u003cp\u003eA: Yes. In the standard nomenclature system, the -99 option flag denotes a custom or non-standard electrical length configuration that must be validated against the total 5.0-meter or 9.0-meter calibration curve of the specific Proximitor loop in use.\u003c\/p\u003e\n\u003cp\u003eQ: Is this coaxial interconnect cable rated for live connection or removal (hot-swapping) while the turbine monitor is online?\u003c\/p\u003e\n\u003cp\u003eA: Disconnecting the coaxial circuit during machine operation disrupts the continuous RF loop, causing the associated machinery protection module to flag a Transducer Fault (NOT OK status). This channel must be placed in a bypassed state before separating the coaxial links to avoid tripping executive shutdown relays.\u003c\/p\u003e\n\u003cp\u003eQ: How does mechanical deformation or crushing of the cable jacket alter the proximity measurement loop?\u003c\/p\u003e\n\u003cp\u003eA: Crushing forces compress the internal dielectric spacing between the center conductor and the outer shield layer. This compression shifts the internal capacitance profile, corrupting the factory-set eddy-current probe scaling and introducing measurement errors in the displacement data.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBending Radius Restrictions\u003c\/strong\u003e: Do not route the coaxial cable past a minimum structural bend radius of 25.4 mm (1.0 in). Sharp bends or kinks induce permanent internal impedance variances that invalidate the baseline instrument calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCoaxial Connector Engagement\u003c\/strong\u003e: Hand-tighten the miniature coaxial interfaces until a mechanical click or full thread engagement is reached. Do not apply heavy wrenches or pliers, which can fracture the internal insulation layers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding and Ground Isolation\u003c\/strong\u003e: Ensure the outer FEP jacket remains uncompromised throughout the run to prevent the cable shield from making contact with structural machine grounding paths. Single-point grounding must be maintained exclusively at the Proximitor Sensor end.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConduit Protection\u003c\/strong\u003e: Route the interconnect cable inside dedicated flexible or rigid steel conduit paths to protect the low-voltage analog signal from ambient electromagnetic interference and physical abrasion from surrounding infrastructure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe standard procurement item comprises the following components:\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e(1) 16710-99 Interconnect Cable assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e(2) Heavy-duty transparent silicone environmental connector protectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e(1) Technical parameters verification sheet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e(1) Cable routing tag set.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eDispatch and Shipping Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLogistics Window\u003c\/strong\u003e: 2-7 days when payment finish through authorized commercial banking transactions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransit Management\u003c\/strong\u003e: Forwarded globally via high-priority express channels including DHL, FEDEX, or UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eContainment Protocol\u003c\/strong\u003e: Packaged in rigid, specialized anti-static industrial packaging enclosures fitted with humidity absorption elements to prevent electrical dielectric degradation prior to field installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518869495981,"sku":"16710-99","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-16710-99-interconnect-cable-qjiovj1aexe.jpg?v=1766980640","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-16710-99-interconnect-cable","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}