{"product_id":"bently-nevada-138607-01-3500-22m-transient-data-interface-module-3500-series","title":"Bently Nevada 138607-01 3500\/22M Transient Data Interface Module 3500 Series","description":"\u003cp\u003eConfigured for high-speed waveform acquisition in 3500 machinery protection system platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 138607-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e3500\/22M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTransient Data Interface Module) provides direct physical and electrical execution of diagnostic data streaming for rotating machinery condition monitoring.\u003c\/p\u003e\n\u003ch3\u003eModel Configuration Matrix\u003c\/h3\u003e\n\u003cp\u003eThe 138607-01 serves as the Transient Data Interface (TDI) for the 3500 rack system. It combines Rack Interface Module (RIM) functionality with a dedicated communication processor, enabling the extraction of static and dynamic vibration data from M-series monitor modules for external analysis platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e138607-01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.8 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.6 cm x 25.8 cm x 24.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 deg C to +65 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.0 Watts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEthernet 10\/100 Base-T\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and TSI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 3500\/22M module manages rotor dynamics data streams by performing continuous waveform sampling of transducer inputs. It validates eddy-current probe scaling to ensure that transient captured data corresponds to accurate physical displacement measurements. The module enforces gap voltage validation (-10 VDC targets) during start-up and steady-state monitoring to prevent false trigger events. To maintain system-wide TSI synchronization, the 3500\/22M implements rigorous cross-talk suppression on the rack backplane, ensuring that high-speed diagnostic data does not interfere with critical protection relay logic execution.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e138607-01 3500\/22M Transient Data Interface Module (Main board)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard I\/O module (Rear rack interface)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfiguration software package\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDocumentation and hardware installation guides\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInstall the module in the designated slot adjacent to the 3500 power supplies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnect the primary Ethernet port to the diagnostic workstation network using shielded Category 5e cabling or better.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify the IP configuration matches the facility network scheme prior to data acquisition attempts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure the module firmware is compatible with the version of the monitor modules installed in the rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecure the front-panel captive screws to ensure a proper ground bond to the 3500 rack chassis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this module operate without a network connection?\u003c\/p\u003e\n\u003cp\u003eA: Yes, it continues to execute local rack functions and protection interface tasks, though diagnostic data streaming to external software will be disabled.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does it support hot-swapping?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the 3500\/22M supports hot-swapping in a powered 3500 rack, although this will interrupt diagnostic data flow to external platforms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the 3500\/22M compatible with older 3500\/22 modules?\u003c\/p\u003e\n\u003cp\u003eA: The 3500\/22M is the specific hardware revision for transient data interfacing; refer to the compatibility matrix in the system manual for specific firmware requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does the module handle high volumes of waveform data?\u003c\/p\u003e\n\u003cp\u003eA: It utilizes an internal high-speed processor to buffer transient events before transmitting them via the Ethernet interface to condition monitoring software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does it replace the standard Rack Interface Module?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the 3500\/22M incorporates the standard RIM functionality for rack-wide communication and backplane management.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What indicates an Ethernet communication loss?\u003c\/p\u003e\n\u003cp\u003eA: The \"COMM\" LED on the module faceplate will provide status indicators, and the diagnostic software will report a loss of packet transmission.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is external power required for the Ethernet port?\u003c\/p\u003e\n\u003cp\u003eA: No, the Ethernet port is powered internally by the 3500 rack backplane via the module's power conversion circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I use multiple TDI modules in one rack?\u003c\/p\u003e\n\u003cp\u003eA: Only one TDI module is permitted per 3500 rack to manage backplane communications and diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45378091909293,"sku":"138607-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-3500-22m-138607-01-transient-data-interface-module-2f4h5oagwvm.jpg?v=1764225523","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-138607-01-3500-22m-transient-data-interface-module-3500-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}