{"product_id":"bently-nevada-106765-16-interconnect-cable-transducer","title":"Bently Nevada 106765-16 Interconnect Cable Transducer","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 106765-16\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e106765-16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInterconnect Cable, operates as a dedicated hardware component for high-fidelity proximity signal transmission within Turbine Supervisory Instrumentation (TSI) systems. It connects proximity probes or acceleration transducers directly to proximity sensor extension cables or rack-mounted monitor modules, ensuring the raw electrical signal paths remain unaltered over designated distances.\u003c\/p\u003e\n\u003ch3\u003ePhysical and Electrical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e106765-16\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Platform\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500 Machinery Protection System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Classification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTransducer Interconnect Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConductor Structure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTwisted, shielded copper pairs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (0 mA internal consumption)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInsulation Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum 100 M\\Omega\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDielectric Strength\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 Vrms connection-to-shield\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.6 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.3 x 20.3 x 5.1 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRelative Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% condensing when properly sealed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling \u0026amp; Gap Voltage Validation\u003c\/h3\u003e\n\u003cp\u003eThe physical layout of this interconnect link matches specific system capacitance and impedance boundaries to maintain linear eddy-current probe scaling values across the full scale. Preserving these electrical properties allows accurate gap voltage validation, targeting the standard -10 VDC operational centers required by proximity monitors. This precision reduces impedance mismatch reflection anomalies, preventing voltage offsets that distort critical rotor dynamics analysis and fluid-film bearing displacement loops.\u003c\/p\u003e\n\u003ch3\u003eTechnical Queries \u0026amp; Diagnostic Logic\u003c\/h3\u003e\n\u003cp\u003eQ: How does the internal shield structure mitigate signal degradation across long routing runs?\u003c\/p\u003e\n\u003cp\u003eA: The twisted pair geometry combined with a continuous aluminum foil shield provides high-performance cross-talk suppression. This layout prevents electrostatic and electromagnetic noise from modulating the high-frequency carrier wave sent by the proximity sensor.\u003c\/p\u003e\n\u003cp\u003eQ: What operational failures occur if the cable insulation resistance drops below 100 M\\Omega?\u003c\/p\u003e\n\u003cp\u003eA: A drop in insulation resistance creates a parallel leakage path to ground. This alters the constant-current drive loop, shifts the target gap voltage outside validation limits, and introduces measurement drift in the active vibration channel.\u003c\/p\u003e\n\u003cp\u003eQ: Can this passive cable assembly be modified or spliced in the field during turnaround?\u003c\/p\u003e\n\u003cp\u003eA: No. Splicing alters the intrinsic line capacitance and resistance parameters per unit length. Any manual field modifications invalidate the factory eddy-current probe scaling, inducing measurement errors within the associated machinery protection monitor.\u003c\/p\u003e\n\u003ch3\u003eField Component Installation Protocols\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShield Grounding Boundary:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnect the integrated copper drain wire exclusively to the instrument ground terminal strip at the monitor enclosure end. Isolate the field transducer end of the shield completely to prevent ground loop currents from skewing voltage feedback.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Bend Constraints:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain a minimum structural bend radius of 25.4 mm during installation routing. Sharp kinks or tight bends degrade the physical dielectric separation layer, shifting the operational capacitance parameters of the wire.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConduit and Terminal Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRun the interconnect cabling inside solid or flexible dedicated metallic conduit systems. Seal all connection boxes to prevent moisture accumulation, oil ingress, or chemical exposure from breaking down the outer insulation jacket.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProcurement Manifest\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Bently Nevada 106765-16 Interconnect Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Engineering Pinout Terminal Reference Guide\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNote: Proximity sensors, extension cables, and threaded bulkhead connectors are not included with this component.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping Logistics \u0026amp; Protocols\u003c\/h3\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish verification is logged in the system. Dispatches depart from Xiamen, China via prioritized transport networks handled by DHL, FEDEX, or UPS. The components travel enclosed within sealed anti-static industrial packaging matrices with moisture-absorbent packets to guarantee physical shielding and eliminate ESD degradation vectors during transit.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518821818541,"sku":"106765-16","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-106765-16-interconnect-cable-o5l3cx42jxw.jpg?v=1766979560","url":"https:\/\/www.maxwellplc.com\/products\/bently-nevada-106765-16-interconnect-cable-transducer","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}