{"product_id":"bdfc-01c-abb-fan-control-and-brake-chopper-board-acs880","title":"BDFC-01C ABB Fan Control and Brake Chopper Board ACS880","description":"\u003cp data-path-to-node=\"4\"\u003eConfigured for DC link voltage regulation and braking unit modulation in ACS880 drive systems, the \u003cb data-path-to-node=\"4\" data-index-in-node=\"99\"\u003eABB BDFC-01C\u003c\/b\u003e (\u003cb data-path-to-node=\"4\" data-index-in-node=\"113\"\u003eBDFC-01C\u003c\/b\u003e Fan Control and Brake Chopper Board) provides direct electrical execution for energy dissipation processes within frame R8i hardware.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"5\"\u003eModel Identification\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eModel:\u003c\/b\u003e BDFC-01C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eModule Type:\u003c\/b\u003e Fan Control and Brake Chopper Board\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eSystem Family:\u003c\/b\u003e ACS880 (Frame R8i)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"8\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,0,0\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,1,0\"\u003eBDFC-01C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,0,0\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,1,0\"\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,0,0\"\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,1,0\"\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,0,0\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,1,0\"\u003e0.6 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,0,0\"\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,1,0\"\u003e23.3 x 18.3 x 5.3 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,0,0\"\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,1,0\"\u003e-20 deg C to +60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,0,0\"\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,1,0\"\u003eSystem-dependent\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,0,0\"\u003eModulation Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,1,0\"\u003e1 kHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,0,0\"\u003ePhase Displacement\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,1,0\"\u003e120-degree shift\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"9\"\u003eDrive Control Characteristics\u003c\/h3\u003e\n\u003cp data-path-to-node=\"10\"\u003eThe BDFC-01C maintains deterministic backplane bus communication velocity and supports firmware flash compatibility required for synchronized operation with UCU-x2 control units. The module facilitates I\/O density scaling by allowing multiple converter modules to operate in parallel, ensuring that energy dissipation logic remains synchronized across high-wattage industrial drive arrays. Profinet\/EtherNet\/IP deterministic networks are utilized for status reporting from the board to the host controller.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"11\"\u003eOrdering Information\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003eOne (1) BDFC-01C Control Interface Board.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003eInterface connector set for UCU-x2 integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003eTechnical safety and thermal management documentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"13\"\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eMounting:\u003c\/b\u003e Ensure the board is firmly seated in the R8i drive module option slot; verify that all signal connectors are locked to prevent disconnects under vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eThermal Management:\u003c\/b\u003e Maintain ambient conditions within the specified -20 deg C to +60 deg C range; ensure that cooling fans are operational to prevent thermal derating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eWiring:\u003c\/b\u003e Connect external brake resistors according to the drive wiring diagrams, ensuring proper shielding to mitigate electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003e\u003cb data-path-to-node=\"14,3,0\" data-index-in-node=\"0\"\u003eDiagnostics:\u003c\/b\u003e Monitor current symmetry and phase balance during the initial power-up sequence to confirm correct board integration and phase timing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"15\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul data-path-to-node=\"16\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,0,0\"\u003e\u003cb data-path-to-node=\"16,0,0\" data-index-in-node=\"0\"\u003eIs the BDFC-01C hot-swappable?\u003c\/b\u003e No, the drive power must be isolated and DC bus capacitors fully discharged before installing or removing the board.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,1,0\"\u003e\u003cb data-path-to-node=\"16,1,0\" data-index-in-node=\"0\"\u003eWhat is the primary function of the 1 kHz modulation?\u003c\/b\u003e The 1 kHz frequency regulates the pulse-width modulation (PWM) of the IGBTs to effectively control DC link energy dissipation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,2,0\"\u003e\u003cb data-path-to-node=\"16,2,0\" data-index-in-node=\"0\"\u003eHow does it manage phase displacement?\u003c\/b\u003e It utilizes a 120-degree phase shift to minimize DC voltage ripple, protecting the capacitor bank from excessive stress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,3,0\"\u003e\u003cb data-path-to-node=\"16,3,0\" data-index-in-node=\"0\"\u003eCan it operate in parallel configurations?\u003c\/b\u003e Yes, the board is designed to support synchronized operation across multiple converter modules in heavy-duty applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,4,0\"\u003e\u003cb data-path-to-node=\"16,4,0\" data-index-in-node=\"0\"\u003eDoes it provide thermal protection?\u003c\/b\u003e Yes, it includes integrated thermal monitoring to protect both the IGBTs and the external resistor bank from runaway conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,5,0\"\u003e\u003cb data-path-to-node=\"16,5,0\" data-index-in-node=\"0\"\u003eHow are imbalances detected?\u003c\/b\u003e The module logic continuously monitors phase currents and symmetry; any deviation triggers a hardware-level fault to prevent damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,6,0\"\u003e\u003cb data-path-to-node=\"16,6,0\" data-index-in-node=\"0\"\u003eIs firmware update required?\u003c\/b\u003e Compatibility is version-dependent; verify the UCU-x2 control unit firmware supports the BDFC-01C hardware revision.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,7,0\"\u003e\u003cb data-path-to-node=\"16,7,0\" data-index-in-node=\"0\"\u003eWhat is the function of the 120-degree shift?\u003c\/b\u003e This phase shift management is required to reduce DC voltage ripple, ensuring stable operation of the drive internal capacitors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45231169077421,"sku":"BDFC-01C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-bdfc-01c-fan-control-panel-gxmrdcs4kr4_516f4809-904d-41ec-a145-f286a258bf4e.jpg?v=1762942248","url":"https:\/\/www.maxwellplc.com\/products\/bdfc-01c-abb-fan-control-and-brake-chopper-board-acs880","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}