{"product_id":"ax561-1tne968902r1301-abb-analogue-i-o-module-ac500","title":"AX561 1TNE968902R1301 ABB Analogue I\/O Module AC500","description":"\u003cp\u003eConfigured for analog signal measurement and control loop output in ABB AC500 PLC systems, the \u003cstrong\u003eABB AX561 1TNE968902R1301\u003c\/strong\u003e (\u003cstrong\u003eAX561\u003c\/strong\u003e Analogue I\/O Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eChannel Configuration \u0026amp; Model Structure\u003c\/h3\u003e\n\u003cp\u003eThe AX561 expansion module integrates field transmitter inputs and control actuator outputs into a single DIN-rail terminal footprint. Product details include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePrimary Module Code: AX561\u003c\/li\u003e\n\u003cli\u003eGlobal Order Number: 1TNE968902R1301\u003c\/li\u003e\n\u003cli\u003eChannel Count: 4 Analog Inputs \/ 2 Analog Outputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Data Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAX561 1TNE968902R1301\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eChina, Germany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.16 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e13.4 x 7.3 x 4.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.0 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e4 Channels (2-wire input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e2 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Resolution\u003c\/td\u003e\n\u003ctd\u003e12-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e85044040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDispatch Location\u003c\/td\u003e\n\u003ctd\u003eXiamen, China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eNetwork Protocol \u0026amp; Deterministic Bus Performance\u003c\/h3\u003e\n\u003cp\u003eThe AX561 module transfers converted analog values over the internal backplane bus to the CPU processing core. Processing performance supports I\/O density scaling and maintaining firmware flash compatibility across controller families. Signal scanning timing integrates deterministic networks capabilities for Profinet \/ EtherNet\/IP distributed I\/O architectures.\u003c\/p\u003e\n\u003ch3\u003eDelivery Package Items\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x ABB AX561 1TNE968902R1301 Analogue I\/O Module\u003c\/li\u003e\n\u003cli\u003e1 x Removable Terminal Block Set\u003c\/li\u003e\n\u003cli\u003e1 x Installation Manual Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Assembly \u0026amp; Cable Termination Rules\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower Isolation Protocol\n\u003cul\u003e\n\u003cli\u003eIsolate the 24 VDC auxiliary power supply prior to mounting or removing the module from the DIN rail base.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eStatic Discharge Protection\n\u003cul\u003e\n\u003cli\u003eWear a grounded ESD wrist strap during handling to avoid damaging internal 12-bit converter circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSignal Wiring Separation\n\u003cul\u003e\n\u003cli\u003eRoute 2-wire analog input loops in shielded twisted-pair cables, keeping 200 mm clearance from AC power lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eTerminal Grounding Connection\n\u003cul\u003e\n\u003cli\u003eConnect cable shields to the main cabinet earthing bar using low-impedance grounding clamps.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Questions \u0026amp; Answers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What input and output channel configuration is provided on the AX561 module?\u003c\/p\u003e\n\u003cp\u003eA: The module provides 4 analog input channels configured for 2-wire transmitter loops and 2 analog output channels with 12-bit digital resolution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What primary auxiliary voltage supply is required for operational power?\u003c\/p\u003e\n\u003cp\u003eA: The module requires an external 24 VDC nominal auxiliary power supply to energize onboard loop circuits and logic logic networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this analog expansion module be hot-swapped while the CPU backplane is active?\u003c\/p\u003e\n\u003cp\u003eA: No, module insertion or removal requires complete removal of system 24 VDC power to prevent backplane signal corruption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does I\/O density scaling function when adding multiple AX561 units?\u003c\/p\u003e\n\u003cp\u003eA: Additional modules attach sequentially along the AC500 side-bus interface up to the maximum expansion address limit allowed by the CPU core.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How is electrical noise suppressed on analog measuring loops?\u003c\/p\u003e\n\u003cp\u003eA: Twisted-pair shielded cables must be grounded 360 degrees at the entry point of the electrical cabinet to reject field interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What are the physical shipping weight and outer box dimensions?\u003c\/p\u003e\n\u003cp\u003eA: The packaged module weighs 0.16 kg and measures 13.4 cm in length, 7.3 cm in width, and 4.3 cm in height.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What operating ambient thermal parameters must be maintained in the enclosure?\u003c\/p\u003e\n\u003cp\u003eA: Control cabinet interior temperatures must remain within 0 deg C to +60 deg C for normal operational compliance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does firmware flash compatibility affect system expansion?\u003c\/p\u003e\n\u003cp\u003eA: Matching module hardware revisions to the CPU firmware ensures automatic parameter mapping and predictable bus scan timing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021125275821,"sku":"1TNE968902R1301","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/ax561_1tne968902r1301_1.jpg?v=1791903161","url":"https:\/\/www.maxwellplc.com\/products\/ax561-1tne968902r1301-abb-analogue-i-o-module-ac500","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}