{"product_id":"allen-bradley-2711p-rp8d-panelview-plus-6-logic-module-hmi","title":"Allen-Bradley 2711P-RP8D PanelView Plus 6 Logic Module HMI","description":"\u003cp\u003eConfigured for DC-powered logic execution in the PanelView Plus 6 700-1500 platform, the \u003cstrong\u003eAllen-Bradley 2711P-RP8D\u003c\/strong\u003e (\u003cstrong\u003e2711P-RP8D\u003c\/strong\u003e Logic Module) provides the processing hardware for compatible PanelView Plus 6 terminals. Rockwell Automation identifies this catalog number as a DC-input logic module with Windows CE 6.0 and no options.\u003c\/p\u003e\n\u003ch3\u003eProduct Identification\u003c\/h3\u003e\n\u003cp\u003eThe 2711P-RP8D is a PanelView Plus 6 700-1500 logic module. It is not an 8-inch display module; the display and logic module are separate hardware components in this product family. Rockwell Automation lists the 2711P-RP8D as discontinued effective September 30, 2023.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711P-RP8D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003ePanelView Plus 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eLogic Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003ePanelView Plus 6 700-1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating System\u003c\/td\u003e\n\u003ctd\u003eWindows CE 6.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Input\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlash Memory\u003c\/td\u003e\n\u003ctd\u003e1 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAM\u003c\/td\u003e\n\u003ctd\u003e512 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNonvolatile Application Storage\u003c\/td\u003e\n\u003ctd\u003e80 MB listed by Rockwell Automation product page\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptions\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eDetermined by compatible terminal configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.58 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e21 × 13.6 × 4.4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eRefer to the complete PanelView Plus 6 terminal configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eManufacturer value not published specifically for the RP8D logic module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States of America\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifecycle\u003c\/td\u003e\n\u003ctd\u003eDiscontinued\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eRockwell documentation identifies the 2711P-RP8D as having 1 GB flash and 512 MB RAM, while the current product page separately describes 80 MB of nonvolatile application storage.\u003c\/p\u003e\n\u003ch3\u003eIndustrial Control Platform Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe RP8D provides the computing section of a PanelView Plus 6 700-1500 terminal. Its electrical interface is based on DC power input, while display functionality depends on the separately selected compatible display hardware. Rockwell documentation lists the RP8D among the DC logic modules compatible with PanelView Plus display modules.\u003c\/p\u003e\n\u003cp\u003eThe PanelView Plus 6 architecture separates display modules, logic modules, and communication modules. Therefore, the RP8D should not be treated as a complete HMI terminal when specifying replacement hardware.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 2711P-RP8D PanelView Plus 6 Logic Module\u003c\/li\u003e\n\u003cli\u003e1 x Compatible PanelView Plus 6 terminal assembly is required for complete HMI operation\u003c\/li\u003e\n\u003cli\u003eCompatible display and communication modules are selected separately according to the terminal configuration\u003c\/li\u003e\n\u003cli\u003eNo additional options are identified for catalog number 2711P-RP8D\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Replacement Guidelines\u003c\/h3\u003e\n\u003ch4\u003eDC Power Connection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that the replacement assembly uses the required DC power architecture.\u003c\/li\u003e\n\u003cli\u003eFollow the PanelView Plus installation documentation for power wiring and grounding.\u003c\/li\u003e\n\u003cli\u003eRockwell recommends an isolated and ungrounded DC source for nonisolated DC terminals to reduce ground-loop current.\u003c\/li\u003e\n\u003cli\u003eUse a SELV or PELV power source where required by the applicable installation code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eModule Installation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect power before removing or installing the logic module.\u003c\/li\u003e\n\u003cli\u003eConfirm the display module and communication configuration are compatible with the replacement logic module.\u003c\/li\u003e\n\u003cli\u003eVerify catalog number and hardware configuration before applying power.\u003c\/li\u003e\n\u003cli\u003eKeep signal and power wiring separated according to the installation documentation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 2711P-RP8D a complete HMI terminal?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. It is the logic module for PanelView Plus 6 700-1500 terminals. A compatible display module is required for a complete operator terminal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 2711P-RP8D use AC or DC power?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 2711P-RP8D is a DC-input logic module. Rockwell specifically lists DC power input for this catalog number.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow much memory does the RP8D have?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRockwell installation documentation identifies the RP8D with 1 GB flash and 512 MB RAM. This differs from the 512 MB Flash\/RAM description supplied in the original product data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the RP8D contain the display?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The RP8D is a logic module. PanelView Plus 6 display modules use separate catalog numbers and are mechanically combined with the logic module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the RP8D be replaced while the terminal is powered?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePower should be removed before module replacement. Follow the PanelView Plus installation procedure and verify the terminal configuration before re-energizing the assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the RP8D compatible with PanelView Plus display modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Rockwell documentation identifies 2711P-RP8D as a compatible DC logic module for PanelView Plus 6 display configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the RP8D include extended features?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 2711P-RP8D is listed as the standard logic module without options. The related RP9D is identified separately for extended-feature configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 2711P-RP8D still an active model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Rockwell Automation lists the 2711P-RP8D under the discontinued PanelView Plus 6 700-1500 logic module family, with discontinuation dated September 30, 2023.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45519108866221,"sku":"2711P-RP8D","price":699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/allen-bradley_2711p-rp8d_1.jpg?v=1787202235","url":"https:\/\/www.maxwellplc.com\/products\/allen-bradley-2711p-rp8d-panelview-plus-6-logic-module-hmi","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}