{"product_id":"allen-bradley-2711p-rn15s-communication-module-controlnet","title":"Allen-Bradley 2711P-RN15S Communication Module ControlNet","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 2711P-RN15S\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2711P-RN15S\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCommunication Module, operates as a dedicated hardware component for ControlNet network connectivity within PanelView Plus and PanelView Plus CE operator terminal platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Identification Data\u003c\/h3\u003e\n\u003cp\u003eThe 2711P-RN15S serves as a communication adapter facilitating deterministic data exchange. The following table details the physical and technical specifications associated with this module.\u003c\/p\u003e\n\u003ch3\u003ePhysical and Operational Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2711P-RN15S\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.35 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.5 x 12.8 x 4.3 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModule Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControlNet Communication Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePorts\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x ControlNet BNC, 1 x RJ45 NAP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSupported Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePanelView Plus \/ CE 700-1500\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNode Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 99 nodes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtocol\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControlNet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eNetwork Determinism and Compatibility\u003c\/h3\u003e\n\u003cp\u003eThis module utilizes the ControlNet protocol to maintain deterministic communication across industrial network topologies. Firmware compatibility is contingent upon the installed version of RSView Studio and RSView Machine Edition Runtime. For unscheduled messaging, v3.10 or later is required for 700-1500 series terminals. Scheduled communication requires v3.20 or later for configuration workstations and v3.20.04.43 or later for the runtime environment. The Network Access Port (NAP) provides a direct interface for module configuration and network diagnostics without requiring an external bridge.\u003c\/p\u003e\n\u003ch3\u003eOrdering and Package Contents\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAllen-Bradley 2711P-RN15S communication module unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe package does not include terminal logic modules, communication cables, or configuration software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation requires the existing logic module hardware on the operator terminal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Installation Directives\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePower Isolation: Ensure all electrical power is removed from the operator terminal prior to hardware installation to prevent electrical arcs or hazardous area incidents.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eESD Precautions: Discharge static electricity by touching a grounded metal surface before handling the module or touching the logic module pins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlignment: Position the module on the upper surface of the logic module. Verify the bottom connector pins are aligned with the receptacle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTorque Specifications: Secure the assembly using the three integrated captive screws. Apply a torque of 0.34 to 0.45 Nm (3 to 4 lb-in) to ensure robust electrical contact and vibration resistance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGlobal Logistics Standards\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShipping via DHL\/FEDEX\/UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAll units are shipped utilizing anti-static industrial packaging to prevent electrostatic discharge and mechanical impact during transit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the function of the RJ45 NAP?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Network Access Port (NAP) is reserved for module-level configuration and temporary diagnostic access to the ControlNet network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module hot-swappable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The system must be de-energized before installing or removing the module to prevent electrical damage to the logic module backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes ControlNet network scheduling errors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eScheduling errors typically result from version mismatches between the configuration workstation (RSView Studio) and the runtime firmware on the PanelView terminal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the module be used with 400-600 series terminals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 2711P-RN15S is designed specifically for PanelView Plus 700-1500 series terminals; it is not compatible with the smaller 400-600 form factors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAre communication cables included with the module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. ControlNet BNC cabling and network taps must be sourced separately based on the specific network layout.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066473140397,"sku":"2711P-RN15S","price":159.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/2711P-RN15S-2.jpg?v=1781067559","url":"https:\/\/www.maxwellplc.com\/products\/allen-bradley-2711p-rn15s-communication-module-controlnet","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}