{"product_id":"allen-bradley-2711-k6c16-operator-interface-panelview-hmi","title":"Allen-Bradley 2711-K6C16 Operator Interface PanelView HMI","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 2711-K6C16\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2711-K6C16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOperator Interface, operates as a dedicated hardware component for localized process visualization and command execution within industrial control systems.\u003c\/p\u003e\n\u003ch3\u003eModel Identification Summary\u003c\/h3\u003e\n\u003cp\u003eThe 2711-K6C16 is a 5.7-inch color TFT display terminal belonging to the PanelView Standard 600 line. It utilizes a 10-key function keypad for operator input and provides native RS-232 (DF1) protocol support for direct controller communication.\u003c\/p\u003e\n\u003ch3\u003eHardware Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2711-K6C16\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.6 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e29 x 19.2 x 11.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConsult Manual\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e34 W DC \/ 60 VA AC (max)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.7 in Color TFT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e320 x 234 pixels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMemory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e190 KB Application Runtime\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18-32 VDC \/ 85-264 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eController Logic and Communication\u003c\/h3\u003e\n\u003cp\u003eThis interface utilizes Profinet \/ EtherNet\/IP deterministic networks via serial-to-protocol conversion where applicable, facilitating data transfer between the operator terminal and the PLC. The firmware architecture supports basic runtime operations, with memory management optimized for 190 KB of application data. The serial printer port supports selectable baud rates ranging from 1200 to 19,200 Kbps, allowing for physical event logging in hard-copy formats.\u003c\/p\u003e\n\u003ch3\u003eOrdering and Package Contents\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAllen-Bradley 2711-K6C16 terminal unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePackage excludes interface cables and installation mounting gaskets unless specified.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePower Isolation: De-energize all primary supply voltages (AC\/DC) before terminal mounting or cable connection to prevent electrical hazards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironmental Sealing: Verify panel cutout dimensions to ensure proper gasket compression, maintaining the integrity of the enclosure seal against industrial contaminants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding Standards: Connect the unit chassis to a dedicated earth ground point to attenuate signal noise on the RS-232 communication lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery Maintenance: Monitor the field-replaceable backup battery periodically; replace according to the runtime warning indicators to preserve volatile memory integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGlobal Logistics Standards\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDispatched via DHL\/FEDEX\/UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAll units utilize anti-static industrial packaging to prevent electrostatic discharge and mechanical shock during transit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the expected service life of the backlight?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe backlight has a half-life of 50,000 hours at 25 deg C; ambient temperatures exceeding this value will accelerate luminance degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the unit operate in hazardous environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit must be enclosed in a suitable cabinet rated for the specific hazardous location Class and Division to maintain safety compliance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the RS-232 port configured?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCommunication parameters, including baud rate and parity, are set within the terminal configuration menu; ensure these match the PLC DF1 driver settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes memory parity errors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eParity or runtime errors often stem from corrupted application files or hardware-level failure in the non-volatile memory chips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the device firmware field-upgradable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe PanelView Standard 600 firmware is static; major functional updates require the use of the original configuration software package and serial transfer cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066472517805,"sku":"2711-K6C16","price":299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/2711-K6C16-1.jpg?v=1780451015","url":"https:\/\/www.maxwellplc.com\/products\/allen-bradley-2711-k6c16-operator-interface-panelview-hmi","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}