{"product_id":"allen-bradley-2711-k3a5l1-operator-interface-panelview-300","title":"Allen-Bradley 2711-K3A5L1 Operator Interface PanelView 300","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 2711-K3A5L1\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2711K3A5L1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOperator Interface, operates as a dedicated hardware component for human-machine interaction and data visualization within DH-485 communication network platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Identification Data\u003c\/h3\u003e\n\u003cp\u003eThe unit is a monochrome keypad-based operator terminal specifically engineered for discrete process monitoring. The identifier 2711-K3A5L1 signifies the hardware configuration including integrated keypad input, monochrome display capability, and designated RS-232 communication architecture.\u003c\/p\u003e\n\u003ch3\u003ePrimary Hardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2711-K3A5L1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.52 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e14 x 8 x 19.6 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 inch Monochrome\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKeypad\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-232 (DH-485) \u0026amp; RS-232 Printer Port\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC Power Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeterministic Network Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe 2711-K3A5L1 utilizes RS-232 physical layer signaling to facilitate data exchange over DH-485 networks. System integration requires strict adherence to communication cabling length limitations and termination resistor specifications to maintain signal integrity within the deterministic network topology. Firmware flash compatibility is managed via the integrated programming port, requiring specific RSLinx driver configurations for successful host-to-terminal data synchronization.\u003c\/p\u003e\n\u003ch3\u003eLogistics and Package Contents\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 2711-K3A5L1 Operator Terminal unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Installation gasket and mounting hardware clips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Terminal block for DC power input.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNote: Communication cables and programming software are sold separately.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Integration Procedures\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e: Ensure the control panel cutout dimensions meet factory specifications to maintain NEMA\/IP rating integrity. Secure the four mounting clips evenly to provide uniform compression on the front gasket.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding\u003c\/strong\u003e: Establish a low-impedance earth ground connection to the terminal chassis to mitigate electromagnetic interference (EMI).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring\u003c\/strong\u003e: Use shielded twisted-pair cabling for DH-485 communication lines. Route signal lines separately from high-voltage AC power cabling to prevent noise coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePowering\u003c\/strong\u003e: Verify the 24 VDC power source is filtered and regulated prior to connection to avoid voltage transients during startup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDistribution Logistics\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDispatched via DHL\/FEDEX\/UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAll units are sealed in anti-static industrial packaging to prevent electrostatic discharge (ESD) and mechanical shock during transit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary communication protocol supported by this terminal?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit utilizes the DH-485 protocol over an RS-232 physical link.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit support hot-swapping during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, power must be disconnected before connecting or disconnecting the terminal from the communication network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the expected service life of the monochrome backlight?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe backlight intensity will degrade over time; maintenance intervals should be aligned with the industrial environment's duty cycle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the terminal compatible with current firmware updates?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCompatibility depends on the existing terminal firmware version and the targeted development software environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow should the keypad be cleaned?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse a soft cloth dampened with mild detergent; avoid abrasive solvents that may damage the membrane overlay.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum cable length for the DH-485 link?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe total segment length is typically limited to 1219 meters (4000 feet) depending on the cable type and node count.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the power supply tolerance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit requires a nominal 24 VDC supply; verify the voltage remains within the manufacturer's specified percentage range to ensure stable operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066472353965,"sku":"2711-K3A5L1","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/allenbradley_2711-k3a5l1_2.jpg?v=1780451936","url":"https:\/\/www.maxwellplc.com\/products\/allen-bradley-2711-k3a5l1-operator-interface-panelview-300","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}