{"product_id":"allen-bradley-193-ecpm3-panel-mount-adaptor-e3-plus","title":"Allen-Bradley 193-ECPM3 Panel Mount Adaptor E3 Plus","description":"\u003cp\u003eConfigured for mechanical transition in motor control center applications, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 193-ECPM3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e193ECPM3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePanel Mount Adaptor) provides direct physical execution of relay mounting for standalone or DIN-rail configurations.\u003c\/p\u003e\n\u003ch3\u003eCatalog Identification\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e193-ECPM3: Base catalog number for the E3 Plus panel mount adaptor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApplication: Designated specifically for mounting the 193-ECXE series electronic overload relays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e193-ECPM3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePer OEM standard (0.2 kg approx.)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePer OEM standard (15 x 10 x 5 cm approx.)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN Rail (EN 50 022-35) or Panel Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCompatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e193-ECXE Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot applicable (Passive mechanical component)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eControl Logic and Backplane Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe 193-ECPM3 functions as a mechanical interface to isolate the 193-ECXE series relay from direct contactor mounting. It supports deterministic network integration by ensuring the relay remains positioned for backplane bus communication velocity and I\/O density scaling requirements. By offloading the relay from the contactor, the adaptor maintains structural integrity in high-vibration environments, protecting the relay’s firmware flash compatibility and sensitive internal electronics from mechanical resonance or heat transfer from the contactor coils.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e193-ECPM3 Panel Mount Adaptor assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting hardware (screws\/clips) as provided by the manufacturer in standard packaging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNote: Electronic overload relay (193-ECXE) is not included.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDIN-Rail Mounting: Attach the adaptor directly to a standard 35 mm top-hat DIN rail (EN 50 022-35) until the spring-loaded release mechanism engages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePanel Mounting: Secure the adaptor to the enclosure backplane using appropriate fasteners through the integrated mounting holes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelay Installation: Align the 193-ECXE relay with the adaptor slots; verify the physical latch mechanism secures the relay to prevent shifting during operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Ensure the DIN rail is bonded to the main enclosure ground to maintain continuity throughout the control cabinet assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this adaptor provide electrical signal routing? No, the 193-ECPM3 is a mechanical mounting base only; all electrical wiring to the 193-ECXE relay must be performed separately.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this be used for other relay series? No, this adaptor is engineered specifically for compatibility with the 193-ECXE series footprint.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the DIN rail mounting removable? Yes, the unit includes a release tab for extraction from 35 mm rails.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this affect the environmental rating of the relay? The adaptor itself is a passive mechanical support and does not alter the IP\/NEMA rating of the mounted relay.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre there torque requirements for mounting? Follow standard mechanical fastener torque guidelines for the selected mounting surface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan it be used in high-vibration applications? Yes, the adaptor is designed to provide stable mounting in environments where contactor-mounted relays may suffer from physical stress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the material composition? The housing consists of industrial-grade molded thermoplastic for structural rigidity and dielectric isolation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre there additional mounting accessories required? No, the 193-ECPM3 includes the necessary mechanical interfaces for DIN or panel deployment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066460197037,"sku":"193-ECPM3","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/193-ECPM3-3.jpg?v=1780563159","url":"https:\/\/www.maxwellplc.com\/products\/allen-bradley-193-ecpm3-panel-mount-adaptor-e3-plus","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}