{"product_id":"allen-bradley-1784-pcc-controlnet-communication-card-flex-i-o-series","title":"Allen-Bradley 1784-PCC ControlNet Communication Card FLEX I\/O Series","description":"\u003cp\u003eConfigured for ControlNet network communication in PC-based industrial control systems, the \u003cstrong\u003eAllen-Bradley 1784-PCC\u003c\/strong\u003e (\u003cstrong\u003e1784PCC\u003c\/strong\u003e ControlNet Communication Card) provides direct physical data exchange through a PCMCIA Type II interface.\u003c\/p\u003e\n\u003ch3\u003eModel Identification\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 99.9904%; height: 371.836px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003cth style=\"width: 35.524%; height: 19.5703px;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"width: 59.1203%; height: 19.5703px;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 35.524%; height: 19.5703px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 59.1203%; height: 19.5703px;\"\u003e1784-PCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 35.524%; height: 19.5703px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"width: 59.1203%; height: 19.5703px;\"\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1406px;\"\u003e\n\u003ctd style=\"width: 35.524%; height: 39.1406px;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"width: 59.1203%; height: 39.1406px;\"\u003eControlNet Communication Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1406px;\"\u003e\n\u003ctd style=\"width: 35.524%; height: 39.1406px;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"width: 59.1203%; height: 39.1406px;\"\u003eFLEX I\/O \/ ControlNet Communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 35.524%; height: 19.5703px;\"\u003eConnector Type\u003c\/td\u003e\n\u003ctd style=\"width: 59.1203%; height: 19.5703px;\"\u003e68-pin connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 35.524%; height: 19.5703px;\"\u003ePC Interface\u003c\/td\u003e\n\u003ctd style=\"width: 59.1203%; height: 19.5703px;\"\u003ePCMCIA Type II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 35.524%; height: 19.5703px;\"\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd style=\"width: 59.1203%; height: 19.5703px;\"\u003eControlNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 35.524%; height: 19.5703px;\"\u003ePower Input\u003c\/td\u003e\n\u003ctd style=\"width: 59.1203%; height: 19.5703px;\"\u003e5 VDC at 225 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 35.524%; height: 19.5703px;\"\u003eOrigin\u003c\/td\u003e\n\u003ctd style=\"width: 59.1203%; height: 19.5703px;\"\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 35.524%; height: 19.5703px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 59.1203%; height: 19.5703px;\"\u003e0.15kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1406px;\"\u003e\n\u003ctd style=\"width: 35.524%; height: 39.1406px;\"\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd style=\"width: 59.1203%; height: 39.1406px;\"\u003e6.3 cm x 8.9 cm x 0.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 35.524%; height: 19.5703px;\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd style=\"width: 59.1203%; height: 19.5703px;\"\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1406px;\"\u003e\n\u003ctd style=\"width: 35.524%; height: 39.1406px;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"width: 59.1203%; height: 39.1406px;\"\u003e5 VDC at 225 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 35.524%; height: 19.5703px;\"\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd style=\"width: 59.1203%; height: 19.5703px;\"\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Function\u003c\/td\u003e\n\u003ctd\u003eControlNet network communication interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHost Connection\u003c\/td\u003e\n\u003ctd\u003ePCMCIA Type II slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connector\u003c\/td\u003e\n\u003ctd\u003e68-pin connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Compatibility\u003c\/td\u003e\n\u003ctd\u003eControlNet communication architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eDirect insertion into compatible PCMCIA interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Status\u003c\/td\u003e\n\u003ctd\u003eDiscontinued by manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare Models\u003c\/td\u003e\n\u003ctd\u003e1784PCC, 1784-PCC\/B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eControlNet Network Interface Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 1784-PCC provides ControlNet communication access from a compatible personal computer platform through a PCMCIA Type II hardware interface. The card transfers network data between the host computer and ControlNet infrastructure through the dedicated communication connector.\u003c\/p\u003e\n\u003cp\u003eThe Allen-Bradley ControlNet architecture uses scheduled and unscheduled communication mechanisms for deterministic industrial network data exchange. The 1784-PCC is designed for connection to ControlNet systems requiring PC-based configuration, monitoring, or communication access.\u003c\/p\u003e\n\u003cp\u003eFor Allen-Bradley industrial control platforms, firmware and software compatibility must be verified between the communication card revision, host operating system, and ControlNet configuration tools. Network addressing and communication parameters are managed through the connected ControlNet system configuration environment.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 1784-PCC ControlNet Communication Card\u003c\/li\u003e\n\u003cli\u003e1 x 68-pin communication connector interface\u003c\/li\u003e\n\u003cli\u003eAdditional software, manuals, cables, and configuration accessories are not included unless specifically listed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Connection Guidelines\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePCMCIA Installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the host computer supports a compatible PCMCIA Type II interface before installation.\u003c\/li\u003e\n\u003cli\u003ePower down the host equipment before inserting or removing the communication card.\u003c\/li\u003e\n\u003cli\u003eAlign the card connector with the PCMCIA slot guide and insert without excessive mechanical force.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eControlNet Connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUse the specified ControlNet network connection hardware.\u003c\/li\u003e\n\u003cli\u003eMaintain proper cable routing separation from high-voltage power conductors.\u003c\/li\u003e\n\u003cli\u003eConfirm network termination and addressing configuration before placing the communication link into operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding and Electrical Practice\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFollow industrial grounding practices for connected ControlNet equipment.\u003c\/li\u003e\n\u003cli\u003eAvoid unnecessary cable loops and maintain proper shielding continuity.\u003c\/li\u003e\n\u003cli\u003eVerify isolation requirements between communication equipment and external electrical circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan the 1784-PCC be installed in any computer slot?\u003c\/strong\u003e\u003cbr\u003eThe module requires a compatible PCMCIA Type II interface and is not designed for standard PCI or PCIe slots.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat communication network does the 1784-PCC support?\u003c\/strong\u003e\u003cbr\u003eThe card supports Allen-Bradley ControlNet communication through the dedicated network interface connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the operating voltage requirement of the 1784-PCC?\u003c\/strong\u003e\u003cbr\u003eThe card operates from a 5 VDC supply provided through the host PCMCIA interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes the 1784-PCC provide Ethernet communication?\u003c\/strong\u003e\u003cbr\u003eNo. The module is designed for ControlNet communication and does not provide Ethernet network connectivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan the communication card be removed during operation?\u003c\/strong\u003e\u003cbr\u003eHot removal capability is not specified. Power-down installation is recommended for equipment protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat connector type is used on the 1784-PCC?\u003c\/strong\u003e\u003cbr\u003eThe card uses a 68-pin connector interface for communication connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs firmware compatibility required for operation?\u003c\/strong\u003e\u003cbr\u003eYes. Compatible firmware and configuration software must be verified for the connected ControlNet system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat installation factor affects communication performance?\u003c\/strong\u003e\u003cbr\u003eProper cable routing, shielding, grounding, and ControlNet network configuration affect communication stability.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066449973421,"sku":"1784-PCC","price":159.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1784-pcc_1.jpg?v=1785855537","url":"https:\/\/www.maxwellplc.com\/products\/allen-bradley-1784-pcc-controlnet-communication-card-flex-i-o-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}