{"product_id":"allen-bradley-1783-ems08t-stratix-6000-8-port-managed-ethernet-switch","title":"Allen-Bradley 1783-EMS08T Stratix 6000 8 Port Managed Ethernet Switch","description":"\u003cp\u003eConfigured for managed Ethernet communication in Stratix industrial network systems, the \u003cstrong\u003eAllen-Bradley 1783-EMS08T\u003c\/strong\u003e (\u003cstrong\u003e1783-EMS08T\u003c\/strong\u003e Managed Ethernet Switch) provides direct physical network switching execution for EtherNet\/IP and TCP\/IP communication environments.\u003c\/p\u003e\n\u003ch3\u003eModel Identification\u003c\/h3\u003e\n\u003cp\u003eThe 1783-EMS08T is an Allen-Bradley Stratix Ethernet switch with 8 copper ports and optional fiber optic connectivity. It supports managed network functions including VLAN-related industrial communication management, DHCP, BOOTP, FTP, HTTP, Telnet, IGMP, SMTP, and EtherNet\/IP protocol communication.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1783-EMS08T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eStratix 6000 \/ Stratix 5700 Managed Switch Family\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eManaged Ethernet Switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e28.5 x 22.6 x 9.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified in provided data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5.8 W peak dissipation \/ 30 W rated power dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e12 to 48 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirement\u003c\/td\u003e\n\u003ctd\u003e250 mA at 24 VDC, Class 2 \/ SELV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Speed\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Ports\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Port\u003c\/td\u003e\n\u003ctd\u003e1 optional fiber optic transceiver support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Protocols\u003c\/td\u003e\n\u003ctd\u003eTCP\/IP, EtherNet\/IP, Telnet, HTTP, DHCP, BOOTP, FTP, IGMP, SMTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003e16 port indicators, 3 status indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Dissipation\u003c\/td\u003e\n\u003ctd\u003e24.6 BTU\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eIndustrial Ethernet switch installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEtherNet\/IP Network Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 1783-EMS08T operates as a managed Ethernet communication device within Allen-Bradley industrial control networks. The switch supports EtherNet\/IP deterministic communication requirements through managed switching functions and protocol handling.\u003c\/p\u003e\n\u003cp\u003eThe Stratix platform provides compatibility considerations for PLC-based Ethernet architectures, allowing communication paths between ControlLogix, CompactLogix, PLC-5 migration systems, and industrial Ethernet devices.\u003c\/p\u003e\n\u003cp\u003eNetwork configuration functions include TCP\/IP addressing services, DHCP and BOOTP assignment, IGMP support for multicast traffic management, and HTTP\/Telnet access for switch configuration.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 1783-EMS08T Managed Ethernet Switch\u003c\/li\u003e\n\u003cli\u003e1 x Industrial Ethernet switch hardware assembly\u003c\/li\u003e\n\u003cli\u003e1 x Fiber optic transceiver support interface (optional, if configured)\u003c\/li\u003e\n\u003cli\u003eNo PLC processor, I\/O module, or communication cable is included unless specified separately\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePower Connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the supply voltage is within the specified 12 to 48 VDC input range.\u003c\/li\u003e\n\u003cli\u003eUse appropriate industrial DC power wiring practices for Class 2 \/ SELV circuits.\u003c\/li\u003e\n\u003cli\u003eConfirm polarity before energizing the switch.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEthernet Wiring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUse compatible industrial Ethernet cables for 10\/100 Mbps communication.\u003c\/li\u003e\n\u003cli\u003eSeparate communication wiring from high-voltage power conductors to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eConfirm connector condition before network commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration Setup\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAssign valid IP parameters before connecting the switch to an active industrial network.\u003c\/li\u003e\n\u003cli\u003eVerify EtherNet\/IP communication paths after network configuration.\u003c\/li\u003e\n\u003cli\u003eCheck status indicators during startup and troubleshooting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat network protocols are supported by the 1783-EMS08T?\u003c\/p\u003e\n\u003cp\u003eThe switch supports TCP\/IP, EtherNet\/IP, Telnet, HTTP, DHCP, BOOTP, FTP, IGMP, and SMTP communication protocols.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many Ethernet ports are available?\u003c\/p\u003e\n\u003cp\u003eThe module provides 8 copper Ethernet ports and supports 1 optional fiber optic transceiver interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat voltage range is required for operation?\u003c\/p\u003e\n\u003cp\u003eThe switch accepts 12 to 48 VDC input power and operates with a 24 VDC nominal supply requirement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the 1783-EMS08T support EtherNet\/IP networks?\u003c\/p\u003e\n\u003cp\u003eYes. The module is designed for managed industrial Ethernet communication using EtherNet\/IP protocol environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum communication speed?\u003c\/p\u003e\n\u003cp\u003eThe Ethernet interface supports 10\/100 Mbps transmission speeds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs fiber communication supported?\u003c\/p\u003e\n\u003cp\u003eFiber communication is supported through an optional 1 Gigabit fiber optic transceiver configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the switch be used with PLC systems?\u003c\/p\u003e\n\u003cp\u003eYes. It is compatible with Allen-Bradley industrial Ethernet architectures connected to PLC and automation systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat indicators are available for diagnostics?\u003c\/p\u003e\n\u003cp\u003eThe switch provides 16 port indicators and 3 system status indicators for network and hardware monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066449186989,"sku":"1783-EMS08T","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1783-EMS08T_22.jpg?v=1785856456","url":"https:\/\/www.maxwellplc.com\/products\/allen-bradley-1783-ems08t-stratix-6000-8-port-managed-ethernet-switch","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}