{"product_id":"allen-bradley-1756-l84es-controllogix-5580-guardlogix-safety-controller-module-20mb","title":"Allen-Bradley 1756-L84ES ControlLogix 5580 GuardLogix Safety Controller Module 20MB","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Allen-Bradley\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-L84ES\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erepresents the pinnacle of integrated safety and high-performance control within the ControlLogix 5580 family. Engineered for mission-critical applications, this GuardLogix controller manages both standard functional logic and safety-related functions in a single chassis. It provides 20 MB of user memory alongside a dedicated 6 MB safety memory, enabling high-speed execution for complex manufacturing and process safety loops. By achieving SIL 3 and PLe (Performance Level e) ratings, the module ensures maximum personnel protection and equipment integrity in hazardous environments.\u003c\/p\u003e\n\u003cp\u003eIn large-scale industrial sectors—such as automotive assembly, oil and gas, and heavy rotating machinery—the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-L84ES\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eeliminates the need for separate safety and standard hardware. This integration allows for faster data exchange and reduced engineering complexity. The embedded 1 Gbps Ethernet port supports high-performance motion control and safety over EtherNet\/IP, providing the low-latency response times required to bring hazardous equipment to a safe state instantly upon a fault detection.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-L84ES\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes the advanced 5580 hardware architecture to deliver significantly improved scan times and communication throughput compared to previous generations.\u003c\/p\u003e\n\u003ch3\u003eDual-Processor Safety Architecture\u003c\/h3\u003e\n\u003cp\u003eThe controller functions as a primary safety processor. To achieve SIL 3 functional safety, it operates in tandem with a safety partner module, such as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-L8SP\u003c\/strong\u003e. This 1-out-of-2 (1oo2) architecture performs continuous cross-checking of safety logic, ensuring that any internal hardware discrepancy triggers a safe shutdown.\u003c\/p\u003e\n\u003ch3\u003eEmbedded Communication \u0026amp; Capacity\u003c\/h3\u003e\n\u003cp\u003eThe built-in 1 Gbps Ethernet port enables the controller to manage up to 250 EtherNet\/IP nodes directly. This eliminates the requirement for additional communication bridge modules in many architectures, simplifying the chassis layout. The module supports up to 31 standard tasks and 1 dedicated safety task, with the ability to run up to 1000 programs per task, providing massive scalability for complex automation environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e1756-L84ES\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUser Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 MB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 MB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEtherNet\/IP Nodes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 250 Nodes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIL 3, PLe, Cat. 4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEmbedded Ethernet\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 Gbps RJ45 Port\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUSB Port\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 USB 2.0 (12 Mbps) for programming\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLocal I\/O Triggers\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Limit (Event-based)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to 60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C to 85°C (-40°F to 185°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm × 145 mm × 121 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.28 kg (2.81 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003cp\u003eCorrect installation of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-L84ES\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis critical for maintaining safety certifications and system stability.\u003c\/p\u003e\n\u003ch3\u003eChassis and Partner Module Placement\u003c\/h3\u003e\n\u003cp\u003eInstall the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-L84ES\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einto any slot of a 1756 ControlLogix chassis. For SIL 3 applications, the safety partner module (1756-L8SP) must occupy the slot immediately to the right of the controller. Ensure the chassis grounding rail connects to a low-impedance earth ground to protect the high-speed CPU from electrostatic discharge (ESD).\u003c\/p\u003e\n\u003ch3\u003eEnergy Storage Module (ESM)\u003c\/h3\u003e\n\u003cp\u003eThe 1756-L8 series controllers utilize an Energy Storage Module (ESM) instead of a battery to maintain memory during power loss. Verify the ESM is fully seated before powering up the chassis. Do not remove the ESM while the \"OK\" status LED is blinking, as this indicates the controller is still writing data to non-volatile memory.\u003c\/p\u003e\n\u003ch3\u003eNetwork Integrity\u003c\/h3\u003e\n\u003cp\u003eUse Category 6 (Cat6) or higher shielded cables for the embedded 1 Gbps Ethernet port. Maintaining a high-quality network physical layer is essential for Safety over EtherNet\/IP, as excessive packet loss can trigger a safety trip (nuisance shutdown) due to missed watchdog timers.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-L84ES\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides a \"Single-Environment\" engineering advantage, allowing developers to use Studio 5000 Logix Designer for both safety and standard code. This unified approach reduces training costs and speeds up troubleshooting. The controller’s hardware-based safety ensures that safety tasks always take priority over standard tasks, guaranteeing a deterministic response to emergency stop (E-Stop) or light curtain triggers. Its rugged design withstands 30g of operational shock, making it suitable for mounting on machinery where vibration and physical stress are constant factors.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eDelivery and Logistics\u003c\/h2\u003e\n\u003cp\u003eWe offer global logistics solutions to keep your safety-critical projects on track.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDelivery Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3-5 days when payment finish.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Carriers:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExpress dispatch via DHL, FEDEX, or UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eShipped in original Allen-Bradley factory-sealed boxes with full protective inserts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003eQ1: Does the 1756-L84ES require a battery for memory retention?\u003c\/p\u003e\n\u003cp\u003eA1: No. The 5580 series controllers use an Energy Storage Module (ESM) to provide power to flush memory to internal non-volatile storage during a power failure, eliminating the need for lithium batteries.\u003c\/p\u003e\n\u003cp\u003eQ2: Can I use this controller without a safety partner?\u003c\/p\u003e\n\u003cp\u003eA2: The 1756-L84ES will function for standard logic without a partner, but to achieve a SIL 3 safety rating and execute safety tasks, the 1756-L8SP (or L8SPK) partner module is mandatory.\u003c\/p\u003e\n\u003cp\u003eQ3: What is the maximum number of safety tasks supported?\u003c\/p\u003e\n\u003cp\u003eA3: This controller supports exactly 1 safety task. However, this task can contain up to 1000 programs, providing ample space for even the most complex safety logic.\u003c\/p\u003e\n\u003cp\u003eQ4: Is the 1756-L84ES compatible with older 1756-IB16S safety I\/O modules?\u003c\/p\u003e\n\u003cp\u003eA4: Yes. The 1756-L84ES is fully compatible with existing GuardLogix I\/O modules, allowing for seamless upgrades from older 1756-L7S systems.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45913927811245,"sku":"1756-L84ES","price":1999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1756-L84ES_5.jpg?v=1776331226","url":"https:\/\/www.maxwellplc.com\/products\/allen-bradley-1756-l84es-controllogix-5580-guardlogix-safety-controller-module-20mb","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}