{"product_id":"allen-bradley-150-f60nbdb-smart-motor-controller-bulletin-150","title":"Allen-Bradley 150-F60NBDB Smart Motor Controller Bulletin 150","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 150-F60NBDB\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e150-F60NBDB\u003c\/strong\u003e Smart Motor Controller, operates as a dedicated hardware component for solid-state voltage ramping and pump control execution within 3-phase AC power circuits.\u003c\/p\u003e\n\u003ch3\u003eDesignation Breakdown \u0026amp; Frame Architecture\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 150-F60NBDB\u003c\/strong\u003e belongs to the SMC Flex Bulletin 150 solid-state motor controller series. The 150-F60NBDB catalog code identifies an open-structure assembly rated for 60 A continuous current and up to 40 hp output at 460 V AC. It accepts 3-phase line input voltages from 200 to 480 V AC, draws control power from a 100 to 240 V AC supply, and incorporates integrated pump control routines.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e150-F60NBDB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.06 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e7.8 x 24 x 21.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e45 W nominal control circuits loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd\u003e40 hp (at 460 V AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Line Voltage\u003c\/td\u003e\n\u003ctd\u003e200 to 480 V AC, 3-Phase, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Voltage\u003c\/td\u003e\n\u003ctd\u003e100 to 240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eOpen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Type\u003c\/td\u003e\n\u003ctd\u003eBulletin 150, Solid State Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Communications \u0026amp; Firmware Features\u003c\/h3\u003e\n\u003cp\u003eIntegrated into control networks via optional communication adapters, the controller interfaces directly with EtherNet\/IP deterministic networks to pass operational status and fault data to central controllers. Internal microprocessors manage gate-trigger timing for solid-state SCRs while supporting firmware flash compatibility for field updates. High I\/O density scaling on the control terminal block supports multiple programmable auxiliary relay outputs and external control inputs.\u003c\/p\u003e\n\u003ch3\u003ePackage Component List\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 150-F60NBDB Solid-State Smart Motor Controller\u003c\/li\u003e\n\u003cli\u003e1 x Control Terminal Interface Plug Assembly\u003c\/li\u003e\n\u003cli\u003e1 x Product Technical Instruction Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCabinet Installation \u0026amp; Wiring Rules\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect and isolate all main line 3-phase power sources and 100-240 V AC control feeds prior to mounting or servicing.\u003c\/li\u003e\n\u003cli\u003eMount the open enclosure starter chassis vertically on a flat, unpainted metallic surface inside a NEMA or IP rated cabinet.\u003c\/li\u003e\n\u003cli\u003eConnect incoming 3-phase lines (L1, L2, L3) and motor leads (T1, T2, T3) using ring lugs tightened to standard assembly torque specs.\u003c\/li\u003e\n\u003cli\u003eRoute 100 to 240 V AC control wiring in separate wiring channels away from 3-phase power lines to prevent signal coupling.\u003c\/li\u003e\n\u003cli\u003eConnect a heavy-gauge protective earth conductor from the chassis ground lug to the enclosure central PE grounding busbar.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Engineering FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the continuous current capacity of the 150-F60NBDB?\u003c\/p\u003e\n\u003cp\u003eThe 150-F60NBDB is specified for a continuous operating output current rating of 60 A across 3-phase AC motor circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat control voltage must be supplied to the logic terminals?\u003c\/p\u003e\n\u003cp\u003eThe internal control board requires an auxiliary AC control supply voltage ranging between 100 and 240 V AC at 50\/60 Hz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat maximum motor horsepower rating is handled at 460 V AC?\u003c\/p\u003e\n\u003cp\u003eWhen connected across a 460 V AC 3-phase supply line, the controller manages standard AC induction motors rated up to 40 hp.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the 150-F60NBDB come with an enclosed NEMA enclosure?\u003c\/p\u003e\n\u003cp\u003eNo, the unit features an open enclosure construction and requires panel installation inside an industrial cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat main 3-phase line supply voltage range is accepted?\u003c\/p\u003e\n\u003cp\u003eThe main power circuit operates across 3-phase line input voltages from 200 to 480 V AC at 50\/60 Hz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the internal controller logic accommodate software updates?\u003c\/p\u003e\n\u003cp\u003eThe control mainboard features firmware flash compatibility, allowing in-field firmware loading over connected interface modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat specific control algorithms are built into this unit?\u003c\/p\u003e\n\u003cp\u003eThe hardware includes specialized pump control profiles designed to reduce hydraulic surges and fluid hammer during starting\/stopping.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should power wiring be separated from low-voltage control lines?\u003c\/p\u003e\n\u003cp\u003eRun 3-phase main power cables and low-voltage control lines in separate metal conduits to prevent electromagnetic noise interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066391613613,"sku":"150-F60NBDB","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/150-F6_3-2.jpg?v=1786074182","url":"https:\/\/www.maxwellplc.com\/products\/allen-bradley-150-f60nbdb-smart-motor-controller-bulletin-150","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}