{"product_id":"ai830-3bse008518r1-abb-analog-input-modules-s800-i-o","title":"AI830 3BSE008518R1 ABB Analog Input Modules S800 I\/O","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB AI830 3BSE008518R1\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAI830\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAnalog Input Module, operates as a dedicated hardware component for resistive temperature measurement and signal conditioning within Advant 800xA and Symphony Plus control networks.\u003c\/p\u003e\n\u003ch3\u003eModule Configuration\u003c\/h3\u003e\n\u003cp\u003eThe AI830 provides 8 independent channels configured to interface with resistance-based temperature sensors. The hardware performs internal digitization, linearization, and scaling of raw input signals, providing processed engineering unit values to the central controller backplane. The module architecture is fixed and serves as a direct input terminal for 3-wire resistive sensing elements.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAI830\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.24 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.5 x 10.5 x 12 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 (Independent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSensor Support\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePt100, Cu10, Ni100, Ni120\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to 70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFiltering\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 Hz or 60 Hz selectable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eI\/O Density Scaling and Backplane Bus Communication\u003c\/h3\u003e\n\u003cp\u003eThe AI830 module utilizes the S800 I\/O backplane bus to exchange diagnostic and process data with the central controller. The bus communication velocity is optimized for deterministic scanning, ensuring that all 8 channels are refreshed within the module's specified cycle time. High-density mounting in the I\/O rack requires management of the module's bus power consumption; users must ensure the cluster's aggregate power draw does not exceed the capacity of the Module Termination Unit (MTU). Firmware flash compatibility ensures the module maintains synchronization with the host controller’s software revision during system commissioning.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModule unit: 1 x AI830 (3BSE008518R1)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePackaging: Anti-static factory seal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDocumentation: Technical reference manual provided in digital format via manufacturer portal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNote: MTU (Module Termination Unit) sold separately; necessary for field wiring termination\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding and Shielding:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain 3-wire configuration to ensure lead-wire resistance compensation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse shielded twisted-pair cabling for all field-side connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTerminate shields at the cabinet-level ground bus to minimize electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eMounting Requirements:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure the MTU is correctly snapped onto the horizontal DIN-rail before seating the AI830 module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify locking mechanism engagement to prevent signal disconnection under mechanical vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eSignal Loop Constraints:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDo not exceed the maximum lead-wire resistance specified by the sensor type to maintain 0.1 percent accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure field-side RTD elements are ground-isolated from the process piping or vessel to prevent common-mode noise injection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the AI830 require external conversion for RTD signals?\u003c\/p\u003e\n\u003cp\u003eNo, the module performs integrated signal linearization and scaling internally, transmitting processed values directly to the DCS controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the consequence of exceeding lead-wire resistance limits?\u003c\/p\u003e\n\u003cp\u003eExceeding resistance limits introduces measurement offsets that cannot be compensated by the 3-wire circuitry, leading to inaccurate temperature reporting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the 50 Hz\/60 Hz filtering configured?\u003c\/p\u003e\n\u003cp\u003eFiltering is configured through the system software environment at the module object level, matching the site-specific mains frequency to suppress interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the AI830 capable of hot-swapping?\u003c\/p\u003e\n\u003cp\u003eYes, the S800 I\/O architecture supports hot-swapping, allowing module removal and replacement without de-energizing the entire I\/O rack or controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the impact of ground-referenced RTD elements?\u003c\/p\u003e\n\u003cp\u003eGround-referenced sensors create potential ground loops through the module, which may cause erratic signal readings or permanent hardware damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the channels be configured for different sensor types simultaneously?\u003c\/p\u003e\n\u003cp\u003eThe AI830 channel configuration is defined within the module parameters; consult the specific I\/O hardware library version for channel-specific flexibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the module handle sensor open-circuit detection?\u003c\/p\u003e\n\u003cp\u003eThe internal circuitry continuously monitors the loop integrity and reports a status bit to the DCS if the impedance exceeds valid sensor ranges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs there a specific firmware version requirement for 800xA integration?\u003c\/p\u003e\n\u003cp\u003eIntegration requires a compatible hardware library version; users must verify the firmware revision against the system's current hardware support package (HSP).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45231188902061,"sku":"3BSE008518R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-ai830-3bse008518r1-analog-input-module-in0jzggpkm5_7472ed7a-2b47-49a6-8407-0061a9678423.jpg?v=1762942406","url":"https:\/\/www.maxwellplc.com\/products\/ai830-3bse008518r1-abb-analog-input-modules-s800-i-o","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}