{"product_id":"ai523-1sap250300r0001-abb-analog-input-module-ac500","title":"AI523 1SAP250300R0001 ABB Analog Input Module AC500","description":"\u003cp\u003eConfigured for 16-channel analog multi-signal digitizing in AC500 network platforms, the \u003cstrong\u003eABB AI523 1SAP250300R0001\u003c\/strong\u003e (\u003cstrong\u003eAI523\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eChannel Configuration \u0026amp; Signal Variants\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAI523\u003c\/strong\u003e: Base hardware designation for 16-channel universal analog input signal processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1SAP250300R0001\u003c\/strong\u003e: Commercial order number designating standard production units for replacement or expansion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Analog Inputs\u003c\/strong\u003e: Configured individually to accept voltage (U), current (I), RTD temperature sensors, or digital input signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e13-Bit Resolution\u003c\/strong\u003e: Digitizes incoming continuous field signals with 13-bit precision for high-fidelity PLC processing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical \u0026amp; Electrical Data\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAI523 (1SAP250300R0001)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e7.6 x 7.6 x 7.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eAC500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e16 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Types\u003c\/td\u003e\n\u003ctd\u003eVoltage (U), Current (I), RTD, Digital Input (DI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Resolution\u003c\/td\u003e\n\u003ctd\u003e13 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHigh-Density Scalability \u0026amp; System Interconnects\u003c\/h3\u003e\n\u003cp\u003eThe module optimizes I\/O density scaling on the backplane bus, transferring 16 converted analog channels at maximum communication velocity across the internal terminal base. Firm-ware flash compatibility ensures continuous synchronization with CPU system updates without losing channel calibration parameters.\u003c\/p\u003e\n\u003ch3\u003eStandard Package Items\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x ABB AI523 (1SAP250300R0001) Analog Input Module\u003c\/li\u003e\n\u003cli\u003e1 x Anti-Static Protective Packaging Box\u003c\/li\u003e\n\u003cli\u003e1 x Technical Reference Quick Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWiring \u0026amp; Enclosure Instructions\u003c\/h3\u003e\n\u003ch4\u003eCabinet Mounting Guidelines\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSnap the unit onto the corresponding AC500 terminal base secured on a standard 35 mm DIN rail (TH35-7.5).\u003c\/li\u003e\n\u003cli\u003eInstall inside an IP54 or higher protective enclosure to protect the IP20 housing against conductive airborne contaminants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eGrounding \u0026amp; Signal Routing\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eConnect field sensor cabling using shielded twisted pairs grounded at one end to minimize EMI coupling.\u003c\/li\u003e\n\u003cli\u003eMaintain separate wire ducts for high-voltage power lines and low-voltage 24 VDC analog signal cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCan the AI523 module be hot-swapped during continuous operation?\u003c\/p\u003e\n\u003cp\u003eNo, removing or inserting the analog input module while power is applied can damage internal backplane circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat signal types can be connected to the input channels?\u003c\/p\u003e\n\u003cp\u003eThe 16 channels support direct wiring for voltage signals, current signals, RTD temperature sensors, and digital inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the module require an external 24 VDC power connection?\u003c\/p\u003e\n\u003cp\u003eYes, the unit requires a nominal 24 VDC auxiliary power supply fed through the terminal base connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the spatial ingress protection rating for the housing?\u003c\/p\u003e\n\u003cp\u003eThe housing meets IP20 protection guidelines and requires an external industrial enclosure for harsh environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat resolution does the internal analog-to-digital converter deliver?\u003c\/p\u003e\n\u003cp\u003eThe internal converter provides 13-bit resolution across configured analog input measurement ranges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the allowed temperature limits during module operation?\u003c\/p\u003e\n\u003cp\u003eThe module operates reliably within an ambient temperature range of 0 deg C to +60 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many configurable analog outputs are available on this unit?\u003c\/p\u003e\n\u003cp\u003eThe AI523 contains zero analog outputs as it is designed solely for 16 analog input channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should cable shielding be grounded for analog inputs?\u003c\/p\u003e\n\u003cp\u003eConnect the shield directly to the functional earth terminal near the entry point of the control panel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021059215533,"sku":"AI523 1SAP250300R0001","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/ai523_1sap250300r0001_1.jpg?v=1791903531","url":"https:\/\/www.maxwellplc.com\/products\/ai523-1sap250300r0001-abb-analog-input-module-ac500","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}