{"product_id":"abb-yxo116-4890024-lc-1-voltage-monitor-yxo-series","title":"ABB YXO116 4890024-LC\/1 Voltage Monitor YXO Series","description":"\u003cp\u003eThe \u003cstrong\u003eABB YXO116 4890024-LC\/1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eYXO116\u003c\/strong\u003e Voltage Monitor, operates as a dedicated hardware component for continuous voltage level verification and fault detection within ABB control panel architectures. It directly monitors internal supply rails, executing physical limit trip signals when potential fluctuations exceed predefined threshold bands to protect sensitive field control logic from under-voltage or transient over-voltage conditions.\u003c\/p\u003e\n\u003ch3\u003ePart Identification \u0026amp; Version Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eYXO\u003c\/strong\u003e: Hardware chassis designator for the power management family.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e116\u003c\/strong\u003e: Defines the specific module logic and voltage tracking range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4890024-LC\u003c\/strong\u003e: Base printed circuit board and component assembly number.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\/1\u003c\/strong\u003e: Hardware revision suffix indicating updated passive components or internal terminal connection standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eYXO116\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare Part Number\u003c\/td\u003e\n\u003ctd\u003e4890024-LC \/ 4890024-LC\/1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGlobal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e12.1 x 6.3 x 1.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction Type\u003c\/td\u003e\n\u003ctd\u003eSupply Voltage Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003ePanel \/ Enclosure Sub-chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFirmware Flash Compatibility \u0026amp; Integration\u003c\/h3\u003e\n\u003cp\u003eThe YXO116 integrates into standard electrical environments without the need for backplane bus communication velocity licenses. As a localized monitoring layer, it supports higher-level controller hardware running on Profinet or EtherNet\/IP deterministic networks by executing failsafe physical cutoffs or alarm triggers before processor undervoltage errors occur. Subsequent logic revisions maintain firmware flash compatibility with upstream ABB supervisory controllers, preventing I\/O density scaling limitations during phased infrastructure upgrades.\u003c\/p\u003e\n\u003ch3\u003eFulfillment Package Items\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x ABB YXO116 4890024-LC\/1 Voltage Monitor Module\u003c\/li\u003e\n\u003cli\u003e1 x Anti-static ESD packaging bag\u003c\/li\u003e\n\u003cli\u003e1 x Factory test certification slip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Hardware Installation Procedures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMounting and Mechanical Clearances\n\u003cul\u003e\n\u003cli\u003eSecure the module using non-conductive standoffs or assigned enclosure brackets to prevent vibration-induced mechanical stress.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum clearance of 20 mm around the board surfaces to permit passive thermal dissipation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eGrounding and Electrical Cabling\n\u003cul\u003e\n\u003cli\u003eBond the designated ground terminal strictly to the main enclosure earth bus using a low-impedance copper jumper.\u003c\/li\u003e\n\u003cli\u003eRoute voltage sensing wires in isolated raceways, keeping them physically separated from high-current AC motor supply lines to mitigate induced noise spikes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational Frequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the specific physical function of the YXO116 module?\u003c\/p\u003e\n\u003cp\u003eThe hardware continuously measures incoming supply voltages and alters an output contact state if the measured potential falls outside the hardcoded operating window.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the 4890024-LC\/1 module permit hot-swapping while energized?\u003c\/p\u003e\n\u003cp\u003eNo, due to the direct electrical connections, all main and auxiliary power sources must be disconnected prior to installation or replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the unit interface with the main programmable controller?\u003c\/p\u003e\n\u003cp\u003eIt utilizes hardwired discrete signal outputs to communicate voltage health limits directly to standard PLC digital input channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat distinguishes the 4890024-LC base from the 4890024-LC\/1?\u003c\/p\u003e\n\u003cp\u003eThe \/1 suffix denotes a factory-level minor hardware revision, typically involving upgraded passive filter components or an optimized PCB trace layout.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this monitoring hardware be deployed in outdoor environments?\u003c\/p\u003e\n\u003cp\u003eNo, the component lacks environmental IP ratings and must be installed inside a sealed, climate-controlled industrial panel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre there integrated time delays to prevent nuisance tripping?\u003c\/p\u003e\n\u003cp\u003eYes, internal RC filter arrays provide brief hardware-level delay thresholds to ignore microsecond voltage transients and electrical noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the YXO116 require a separate auxiliary power source?\u003c\/p\u003e\n\u003cp\u003eNo, the internal logic and comparison circuits draw the required operating current directly from the voltage lines it actively monitors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the recommended wire gauge for the terminal connections?\u003c\/p\u003e\n\u003cp\u003eStandard 18 AWG to 22 AWG copper wire is sufficient for the sensing terminals due to the high-impedance nature of the measurement inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021143298221,"sku":"YXO116","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb_4890024-lc_yxo116.jpg?v=1785988703","url":"https:\/\/www.maxwellplc.com\/products\/abb-yxo116-4890024-lc-1-voltage-monitor-yxo-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}