{"product_id":"abb-ufc760be42-3bhe004573r0042-high-voltage-interface-board-ac-800pec","title":"ABB UFC760BE42 3BHE004573R0042 High-Voltage Interface Board AC 800PEC","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB UFC760BE42 3BHE004573R0042\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUFC760BE42\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-Voltage Interface Board, operates as a dedicated hardware component for high-speed signal processing and communication bridging within AC 800PEC controller platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Identification\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUFC760BE42\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3BHE004573R0042\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Family:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAC 800PEC \/ System 800xA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUFC760BE42 (3BHE004573R0042)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.32 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e33.0 x 15.2 x 2.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 deg C to +60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC (Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHumidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% (Non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHS Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeterministic Network Communication\u003c\/h3\u003e\n\u003cp\u003eThis module supports deterministic backplane bus communication velocity required for real-time power electronics control. The interface facilitates high-speed data exchange between the central processing unit and power converter stages. Firmware flash compatibility is managed via the host AC 800PEC controller, ensuring that communication protocols remain synchronized with the specific power conversion application requirements.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) UFC760BE42 Interface Board.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStatic-shielded packaging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical compliance documentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCabinet Mounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure adequate airflow clearance around the 2.5 cm profile to maintain thermal operating limits within the -20 deg C to +60 deg C range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Cabling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse shielded twisted-pair cabling for all incoming signal lines to minimize induced electromagnetic noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVerify that the mounting chassis is connected to a low-impedance common ground to ensure effective electromagnetic compatibility (EMC) and shielding performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInsertion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlign the module carefully with the backplane connectors; do not apply excessive force to prevent pin misalignment or damage to the high-density connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this board support hot-swapping?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo, the module should only be inserted or removed when the power to the backplane is isolated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the input voltage range strictly 24 V DC?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module is rated for nominal 24 V DC operation. Ensure the supply is regulated to prevent operational instability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the board protected against high electrical noise?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit utilizes integrated shielding and noise-attenuation circuits designed to mitigate interference from high-power switching stages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this board be used in standard 800xA I\/O racks?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis board is specifically engineered for the AC 800PEC architecture and is not cross-compatible with standard S800 I\/O modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the storage temperature range?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe -40 deg C to +85 deg C storage rating permits transport and stocking in extreme climate conditions without compromising component integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs firmware update required after installation?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFirmware compatibility is dependent on the host controller's software version. Consult the system integration manual prior to commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow are signal errors diagnosed?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCommunication integrity is reported via the AC 800PEC CPU diagnostic logs, identifying link-layer errors or signal timeouts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes high-voltage interlock trips?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThese are typically triggered when the interface board detects signals exceeding defined safety thresholds or when communication heartbeat is lost.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45231153250477,"sku":"3BHE004573R0042","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-ufc760be42-3bhe004573r0042-interface-board-nsk1zwb23ep_523232b3-eabe-43e7-a6d3-00ee68d08f43.jpg?v=1762942123","url":"https:\/\/www.maxwellplc.com\/products\/abb-ufc760be42-3bhe004573r0042-high-voltage-interface-board-ac-800pec","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}