{"product_id":"abb-s800-i-o-di840-3bse020836r1-digital-input-module","title":"ABB S800 I\/O DI840 3BSE020836R1 Digital Input Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe ABB DI840 3BSE020836R1 functions as a high-density, reliable 16-channel digital input module within the S800 I\/O architecture. Engineered for critical industrial automation environments, this module excels in processing discrete signals from field devices such as pushbuttons, switches, and proximity sensors. It integrates seamlessly into broader ABB distributed control systems (DCS) and safety frameworks, offering robust galvanic isolation per channel to protect sensitive control logic from field-side electrical surges. Procurement managers and control engineers rely on the DI840 to maintain high availability in continuous process industries, power generation facilities, and manufacturing plants. Its advanced diagnostics, sequence-of-events (SOE) capability, and hot-swappable design minimize downtime, ensuring real-time data acquisition and maximum operational uptime across complex process loops.\u003c\/p\u003e\n\u003ch2\u003eCore Architecture and Redundancy Options\u003c\/h2\u003e\n\u003cp\u003eThe hardware infrastructure of the DI840 module supports flexible configuration to meet stringent industrial reliability demands. It features a dual-channel structure that permits both single and redundant topologies on the ModuleBus. When deployed in a redundant pair configuration with a matching TU840 or TU841 Extended Termination Unit, the system guarantees bump-free switchover if a hardware fault occurs, maintaining uninterrupted monitoring of critical digital inputs.\u003c\/p\u003e\n\u003cp\u003eThe module incorporates 16 isolated input channels grouped into two distinct isolated blocks. Every individual channel possesses dedicated current-limiting circuitry and digital filtering, which eliminates contact bounce and high-frequency noise from field wiring. Internal microcontrollers constantly execute background self-diagnostics, monitoring internal supply voltages, memory integrity, and channel-level operations, immediately reporting any structural anomalies to the host controllers via the high-speed ModuleBus interface.\u003c\/p\u003e\n\u003ch2\u003eHardware Matrix and Technical Dimensions\u003c\/h2\u003e\n\u003cp\u003eThe following specifications define the physical, electrical, and environmental operational boundaries for the module.\u003c\/p\u003e\n\u003ctable style=\"width: 100%; height: 430.547px;\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\" style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 40.0263%; height: 19.5703px;\"\u003e\u003cstrong\u003eSpecification Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.8147%; height: 19.5703px;\"\u003e\u003cstrong\u003eTechnical Value and Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 40.0263%; height: 19.5703px;\"\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.8147%; height: 19.5703px;\"\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 40.0263%; height: 19.5703px;\"\u003e\u003cspan\u003eProduct Model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.8147%; height: 19.5703px;\"\u003e\u003cspan\u003eDI840\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 40.0263%; height: 19.5703px;\"\u003e\u003cspan\u003eSpare Part Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.8147%; height: 19.5703px;\"\u003e\u003cspan\u003e3BSE020836R1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 40.0263%; height: 19.5703px;\"\u003e\u003cspan\u003eNumber of Input Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.8147%; height: 19.5703px;\"\u003e\u003cspan\u003e16 Channels (Isolated in 2 groups of 8)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 40.0263%; height: 19.5703px;\"\u003e\u003cspan\u003eRated Input Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.8147%; height: 19.5703px;\"\u003e\u003cspan\u003e24 V DC (Operational range: 18 V to 30 V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 40.0263%; height: 19.5703px;\"\u003e\u003cspan\u003eInput Current Limitation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.8147%; height: 19.5703px;\"\u003e\u003cspan\u003e2.5 mA typical per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 40.0263%; height: 19.5703px;\"\u003e\u003cspan\u003eHardware Filter Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.8147%; height: 19.5703px;\"\u003e\u003cspan\u003eConfigurable from 1 ms to 100 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1406px;\"\u003e\n\u003ctd style=\"width: 40.0263%; height: 39.1406px;\"\u003e\u003cspan\u003eIsolation Barrier\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.8147%; height: 39.1406px;\"\u003e\u003cspan\u003e50 V continuous between channels and system logic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 40.0263%; height: 19.5703px;\"\u003e\u003cspan\u003ePower Dissipation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.8147%; height: 19.5703px;\"\u003e\u003cspan\u003e2.5 W maximum at nominal operating conditions\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1406px;\"\u003e\n\u003ctd style=\"width: 40.0263%; height: 39.1406px;\"\u003e\u003cspan\u003eSequence of Events (SOE) Resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.8147%; height: 39.1406px;\"\u003e\u003cspan\u003e1 ms time-stamping accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 40.0263%; height: 19.5703px;\"\u003e\u003cspan\u003eIngress Protection Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.8147%; height: 19.5703px;\"\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 40.0263%; height: 19.5703px;\"\u003e\u003cspan\u003eOperating Temperature Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.8147%; height: 19.5703px;\"\u003e\u003cspan\u003e-25°C to +70°C (-13°F to +158°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 40.0263%; height: 19.5703px;\"\u003e\u003cspan\u003eStorage Temperature Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.8147%; height: 19.5703px;\"\u003e\u003cspan\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 40.0263%; height: 19.5703px;\"\u003e\u003cspan\u003eRelative Humidity Bounds\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.8147%; height: 19.5703px;\"\u003e\u003cspan\u003e5% to 95% non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 40.0263%; height: 19.5703px;\"\u003e\u003cspan\u003eCountry of Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.8147%; height: 19.5703px;\"\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1406px;\"\u003e\n\u003ctd style=\"width: 40.0263%; height: 39.1406px;\"\u003e\u003cspan\u003eHarmonized System Code (HS Code)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.8147%; height: 39.1406px;\"\u003e\u003cspan\u003e85389091\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 40.0263%; height: 19.5703px;\"\u003e\u003cspan\u003ePhysical Module Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.8147%; height: 19.5703px;\"\u003e\u003cspan\u003e0.16 kg (0.35 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 40.0263%; height: 19.5703px;\"\u003e\u003cspan\u003eEstimated Shipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.8147%; height: 19.5703px;\"\u003e\u003cspan\u003e4.5 cm x 10.5 cm x 12.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eField Deployment and Wiring Guide\u003c\/h2\u003e\n\u003cp\u003eProper installation guarantees optimal signal processing and protects the module from electrical interference. Mount the module vertically on a standard DIN rail utilizing the designated S800 termination units (such as the TU840 or TU848). Ensure a minimum clearance space of 20 mm above and below the module assembly to facilitate natural convective cooling and prevent localized thermal build-up within the enclosure.\u003c\/p\u003e\n\u003cp\u003eConnect all field wiring using shielded twisted-pair cables to limit electromagnetic interference. Terminate the cable shields directly at the grounding bar of the cabinet structure; never loop ground wires through the module termination blocks. Ensure all 24 V DC field power supplies are derived from a stabilized, SELV\/PELV certified source to protect the input circuitry against destructive voltage transients. When hot-swapping a module under live system conditions, verify that the locking mechanism on the termination unit is fully disengaged before extraction, and press the new unit firmly until the mechanical latches seat completely.\u003c\/p\u003e\n\u003ch2\u003eIndustrial Survivability and System Integration\u003c\/h2\u003e\n\u003cp\u003eBuilt to withstand harsh, corrosive, and electromagnetically noisy environments, the DI840 features robust internal shielding and high-grade industrial components. It operates efficiently across a wide thermal window up to +70°C without requiring forced-air cooling, making it suitable for remote instrument enclosures located near heavy machinery or process lines.\u003c\/p\u003e\n\u003cp\u003eThe module offers deep integration capabilities with existing plant networks. While native to ABB Symphony Plus and 800xA control systems, its data can be mapped seamlessly into third-party topologies via standard communication interfaces. It operates efficiently alongside Honeywell Experion PKS networks or Bently Nevada machinery monitoring clusters by routing digital state changes through standard PROFIBUS DP or Modbus TCP gateways, providing essential interlock status and operational feedback directly to safety and supervisory control rooms.\u003c\/p\u003e\n\u003ch2\u003eCommercial Logistics and Package Kit\u003c\/h2\u003e\n\u003cp\u003eEvery order processed through our distribution hub includes premium tracking and verified industrial components.\u003c\/p\u003e\n\u003cp\u003eThe shipment package comprises the following components:\u003c\/p\u003e\n\u003cp\u003e(1) One Brand New ABB DI840 3BSE020836R1 Digital Input Module.\u003c\/p\u003e\n\u003cp\u003e(2) Factory-issued product certificate of conformity and quality compliance.\u003c\/p\u003e\n\u003cp\u003e(3) Original hardware installation instruction manual.\u003c\/p\u003e\n\u003cp\u003e(4) Hard-copy reference sheet detailing terminal block connections.\u003c\/p\u003e\n\u003ch2\u003eGlobal Logistics and Packaging Controls\u003c\/h2\u003e\n\u003cp\u003eDelivery Dispatch Time: All orders ship within 2-7 days upon finalized payment confirmation, contingent on immediate stock validation.\u003c\/p\u003e\n\u003cp\u003eWe execute global shipping exclusively through premium air carriers, utilizing DHL, FedEx, and UPS expedited networks to guarantee fast and reliable transit. Every module undergoes rigorous preparation before leaving our facility. We seal each unit inside a heavy-duty, anti-static ESD industrial moisture-barrier bag, surrounded by custom-molded shock-absorbing foam inserts. The entire assembly is housed within a reinforced, double-walled rigid outer carton to withstand the mechanical stresses of international freight transit.\u003c\/p\u003e\n\u003ch2\u003eEngineering Diagnostics FAQs\u003c\/h2\u003e\n\u003cp\u003eQ1: How does the DI840 manage high-frequency signal noise or contact bounce from mechanical field switches?\u003c\/p\u003e\n\u003cp\u003eA1: The module utilizes a combination of hardware-level low-pass filters and programmable digital filter configurations. Engineers can adjust the digital filter time parameter between 1 ms and 100 ms via the control system software. This allows the module to ignore rapid, spurious voltage spikes and contact bounce, ensuring that only stable, valid state changes are registered by the application logic.\u003c\/p\u003e\n\u003cp\u003eQ2: Can the DI840 handle Sequence of Events (SOE) recording, and what is its precision level?\u003c\/p\u003e\n\u003cp\u003eA2: Yes, the module natively supports high-accuracy Sequence of Events tracking. It processes changes in input states with a time-stamping resolution of 1 millisecond. This enables precise chronological event analysis during automated process trips or emergency shutdowns, helping engineers accurately diagnose the root cause of system faults.\u003c\/p\u003e\n\u003cp\u003eQ3: What internal diagnostics does the module perform to detect a hardware failure?\u003c\/p\u003e\n\u003cp\u003eA3: The DI840 monitors its internal operational parameters continuously. It runs real-time checks on internal logic supply voltages, optical isolation barrier integrity, microcontroller clock cycles, and communications across the ModuleBus interface. If any internal variable falls outside safe operating tolerances, the module illuminates its front-facing red 'Fault' LED and transmits a diagnostic alarm package to the central controller.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021165875373,"sku":"3BSE020836R1","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/DI840-1.jpg?v=1779092087","url":"https:\/\/www.maxwellplc.com\/products\/abb-s800-i-o-di840-3bse020836r1-digital-input-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}