{"product_id":"abb-nmbp-01-modbus-plus-communication-adapter-module","title":"ABB NMBP-01 Modbus Plus Communication Adapter Module","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe NMBP-01 is a specialized communication gateway engineered by ABB to bridge the gap between legacy Distributed Control Systems (DCS) and modern industrial networks.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSpecifically designed for the Bailey Net 90 and Infi 90 series,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis adapter facilitates high-speed data translation between the Modbus Plus protocol and standard control infrastructures.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy enabling seamless interoperability,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe NMBP-01 allows plant operators to integrate third-party PLCs,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003evariable speed drives,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand power monitors into a unified Bailey control environment.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts architecture is optimized for real-time arbitration,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring that time-critical process data is transmitted with minimal latency across the network backplane.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eHardware Interface Benchmarks and Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eConstructed for high-availability environments,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe NMBP-01 features a hardened physical design that maintains signal integrity despite electrical noise or mechanical stress.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Identification\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eNMBP-01\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModule Function\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eModbus Plus Interface \/ Protocol Converter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSystem Lineage\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBailey Infi 90 and Net 90 DCS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eConnectivity Options\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupport for Modbus RTU and TCP\/IP bridging\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePhysical Connection\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSecure M12 interface for high-vibration stability\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModule Mass\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e26 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eChassis Footprint\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e3.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 x 13.\u003c\/span\u003e\u003cspan class=\"\"\u003e8 x 17.\u003c\/span\u003e\u003cspan class=\"\"\u003e2 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProtocol Support\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eModbus Plus peer-to-peer and Global Data services\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eData Integrity\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eError checking and diagnostic LED indicators\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturing Origin\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSweden\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHS Tariff Code\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e8537101190\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eIndustrial Implementation and Network Roles\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe NMBP-01 is an essential utility for facilities looking to modernize their control architecture without replacing their entire legacy DCS backbone.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eLegacy System Integration\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eConnecting modern Schneider Electric or third-party Modbus Plus devices directly into the Infi 90 control loop.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRemote Asset Monitoring\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eTransmitting status data from geographically dispersed field devices back to the central DCS operator stations via high-speed tunneling.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMotor Control Center (MCC) Networking\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFacilitating the exchange of energy metrics and fault codes between intelligent motor starters and the primary process controller.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRedundant Communication Paths\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEstablishing secondary data links to ensure process visibility in the event of a primary network failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtocol Conversion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSeamlessly mapping Modbus registers to Bailey function blocks for easier engineering and configuration in the Composer or WinTools environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45518973796525,"sku":"NMBP-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-nmbp-01-modbus-plus-adapter-3ddchv4bwnc.jpg?v=1766983559","url":"https:\/\/www.maxwellplc.com\/products\/abb-nmbp-01-modbus-plus-communication-adapter-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}