{"product_id":"abb-nkmp01-2-infi-90-bailey-redundancy-cable","title":"ABB NKMP01-2 Infi 90 Bailey Redundancy Cable","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe NKMP01-2 is a specialized synchronization link designed for the ABB Bailey Infi 90 distributed control system architecture.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis redundancy cable provides a direct hardware connection between primary and backup Multi-Function Processors,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esuch as the IMMFP11 and IMMFP12 models.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy establishing a dedicated failover path,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe NKMP01-2 ensures that process data and logic states are mirrored in real-time,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing for an instantaneous transition should the primary controller encounter a fault.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis component is essential for maintaining system \"hot standby\" status,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eeliminating the need for intermediary station modules or complex software-driven synchronization.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eCritical Performance Data and Physical Specs\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eDesigned for signal integrity in dense electrical cabinets,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe NKMP01-2 meets the following technical requirements:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturer:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eABB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Identification:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eNKMP01-2\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSystem Family:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eInfi 90 \/ Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCable Length:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e2 Feet (0.\u003c\/span\u003e\u003cspan class=\"\"\u003e6 Meters)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eData Transfer Rate:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUp to 1 Mbps bandwidth\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eElectrical Rating:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e300V AC\/DC maximum\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCurrent Capacity:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e≤ 1A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eThermal Tolerance:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eOperational from -40°C to +80°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eNet Weight:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e2 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePackage Dimensions:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e15.\u003c\/span\u003e\u003cspan class=\"\"\u003e2 x 7.\u003c\/span\u003e\u003cspan class=\"\"\u003e6 x 20.\u003c\/span\u003e\u003cspan class=\"\"\u003e3 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturing Location:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSweden\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProduct Status:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eActive \/ Supported\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eIndustrial Applications and System Resilience\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe NKMP01-2 redundancy cable is a vital hardware interlock used in mission-critical process control where any interruption in logic execution could lead to equipment damage or safety hazards.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts application is standard across high-reliability sectors,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eincluding:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Power Generation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsuring continuous burner management and turbine control synchronization between redundant processor pairs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChemical Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintaining steady-state reactor control by preventing controller downtime during hardware swaps or failures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePetrochemical Refining:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupporting high-availability DCS configurations in remote or hazardous processing areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePulp and Paper:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStabilizing high-speed machinery control loops through robust secondary processor coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBy integrating the NKMP01-2, automation engineers can ensure that their ABB Infi 90 systems remain resilient against single-point processor failures, significantly boosting the overall mean time between failures (MTBF) for the entire control segment.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45518993293485,"sku":"NKMP01-2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-nkmp01-2-redundancy-cable-0vvwmlgrwwh.jpg?v=1766984308","url":"https:\/\/www.maxwellplc.com\/products\/abb-nkmp01-2-infi-90-bailey-redundancy-cable","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}