{"product_id":"abb-nkas01-15-termination-cable-for-symphony-infi-90","title":"ABB NKAS01-15 Termination Cable for Symphony INFI 90","description":"\u003cp\u003eConfigured for signal and power loop propagation in Symphony and INFI 90 control architectures, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB NKAS01-15\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eNKAS01-15\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTermination Cable) provides direct physical electrical interface execution between Multi-Function Processor (MMU) modules and termination assemblies.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Specifications\u003c\/h3\u003e\n\u003cp\u003eThe NKAS01-15 is a standard-length shielded interconnect assembly. The \"15\" suffix denotes a fixed length of 15 feet (4.57 meters). No variable sub-configurations exist for this part number, as it utilizes a uniform conductor gauge and connector termination standard required for INFI 90 system backplane compatibility.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNKAS01-15\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e33 x 15 x 4 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 deg C to +80 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot applicable (Passive)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e300 V AC\/DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWire Gauge\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22–24 AWG\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eControl System Performance\u003c\/h3\u003e\n\u003cp\u003eThe cable utilizes backplane bus communication velocity standards consistent with Symphony INFI 90 hardware. The design incorporates shielding to minimize electromagnetic interference (EMI) and cross-talk, ensuring signal integrity across high-density I\/O configurations. I\/O density scaling remains compliant with standard INFI 90 specifications, as the cable impedance characteristics are matched to the MMU interface requirements, preventing signal attenuation or data corruption in long-run deployments.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eNKAS01-15 Termination Cable assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated connector termination ends\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical installation documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRouting: Avoid running the cable parallel to high-voltage power lines or Variable Frequency Drive (VFD) output cables to maintain signal purity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBend Radius: Adhere to a minimum bend radius of 10 times the outer diameter to prevent internal conductor fatigue.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector Seating: Verify that all pins are aligned before insertion into the MMU or termination unit. Ensure the locking mechanism is fully secured to prevent vibration-induced loosening.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielding: Ensure the cable shield is bonded to the equipment chassis ground at the designated grounding terminal to maximize noise immunity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does this cable support hot-swapping?\u003c\/p\u003e\n\u003cp\u003eA: No. Disconnect all power sources from the MMU and termination unit before disconnecting the cable to avoid electrical shorts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the maximum current capacity?\u003c\/p\u003e\n\u003cp\u003eA: The cable is rated for a continuous current of 5 A; verify that the connected load does not exceed this limit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How do I verify cable integrity if communication errors occur?\u003c\/p\u003e\n\u003cp\u003eA: Use a digital multimeter to check for continuity on each conductor and ensure insulation resistance exceeds required system standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is this cable shielded?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the cable features internal shielding to protect against electrical noise within the control cabinet environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I shorten or extend the 15-foot length?\u003c\/p\u003e\n\u003cp\u003eA: Modifying the length alters the impedance and capacitance characteristics, which can lead to communication errors in Symphony systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does the operating temperature affect the cable?\u003c\/p\u003e\n\u003cp\u003eA: The insulation material is specified for -25 deg C to +80 deg C; exceeding these limits will cause embrittlement or degradation of the outer jacket.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Are the connectors compatible with standard DB-style interfaces?\u003c\/p\u003e\n\u003cp\u003eA: The cable utilizes proprietary ABB INFI 90 system connectors; verify interface compatibility before attempting to connect to non-ABB hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the cable require routine maintenance?\u003c\/p\u003e\n\u003cp\u003eA: Inspect for physical damage or wear to the insulation jacket periodically, especially in areas subjected to vibration or mechanical movement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45231199158445,"sku":"NKAS01-15","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-nkas01-15-termination-cable-jdr3u5gsh50_547d3fe3-51cd-496c-b6c0-e40fcc4f492f.jpg?v=1762942490","url":"https:\/\/www.maxwellplc.com\/products\/abb-nkas01-15-termination-cable-for-symphony-infi-90","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}