{"product_id":"abb-ipchs01-mps-ii-power-module-chassis-infi-90","title":"ABB IPCHS01 MPS II Power Module Chassis Infi 90","description":"\u003cp\u003eConfigured for AC power distribution and modular backplane power routing in ABB Infi 90 systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB IPCHS01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eIPCHS01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePower Module Chassis) provides direct physical and electrical execution. The chassis assembly supports installation of multiple MPS II power modules and a dedicated power monitor module while distributing input and output power through integrated bus bars and terminal interfaces.\u003c\/p\u003e\n\u003ch3\u003eModel Reference\u003c\/h3\u003e\n\u003cp\u003eThe IPCHS01 is supplied as a fixed hardware configuration for ABB Bailey Infi 90 Modular Power System applications. No field-selectable suffix matrix or configurable catalog extension was provided within the available technical documentation.\u003c\/p\u003e\n\u003ch3\u003eElectrical and Mechanical Data\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIPCHS01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMPS II Power Module Chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eBailey Infi 90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e19 in rack mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e100-240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd\u003e20 A max per side input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 8 power modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitor Module Support\u003c\/td\u003e\n\u003ctd\u003e1 power monitor module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Distribution\u003c\/td\u003e\n\u003ctd\u003ePower input bus bars and output bus bars\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5-95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e7.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e45.7 x 30.5 x 48.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlace of Shipment\u003c\/td\u003e\n\u003ctd\u003eXiamen, China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDependent on installed power module configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBackplane Communication and Power Distribution Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe IPCHS01 chassis provides mechanical and electrical integration for modular power conversion assemblies installed within ABB Infi 90 infrastructure. Internal bus bar construction permits parallelized power routing between installed MPS II modules and associated monitoring hardware.\u003c\/p\u003e\n\u003cp\u003eBackplane connection spacing and rack alignment must remain mechanically stable during installation to prevent connector stress under continuous thermal cycling conditions. During module insertion, chassis grounding continuity should be verified prior to energizing AC input feeds.\u003c\/p\u003e\n\u003cp\u003eFirmware interaction occurs through installed power monitoring modules rather than the chassis assembly itself. Compatibility is therefore determined by the installed monitor module revision and associated Infi 90 system firmware environment.\u003c\/p\u003e\n\u003ch3\u003eTechnical Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IPCHS01 support hot insertion of power modules during operation?\u003cbr\u003eA: Hot insertion capability depends on the installed MPS II power module type and site-level redundancy configuration. Input isolation and load transfer procedures should be validated before removal or insertion under energized conditions.\u003c\/p\u003e\n\u003cp\u003eQ: What is the primary function of the integrated bus bars?\u003cbr\u003eA: The internal bus bars distribute incoming AC power to installed power modules and provide centralized output routing within the modular chassis structure.\u003c\/p\u003e\n\u003cp\u003eQ: Can the chassis operate with fewer than eight installed power modules?\u003cbr\u003eA: Yes. The chassis can operate with partial population provided electrical loading remains within system design limits and airflow requirements are maintained.\u003c\/p\u003e\n\u003cp\u003eQ: Is the IPCHS01 directly responsible for process communication functions?\u003cbr\u003eA: No. The chassis provides physical mounting and power distribution. Communication handling is executed by associated Infi 90 control and interface modules.\u003c\/p\u003e\n\u003cp\u003eQ: What installation condition is most critical for long-term connector stability?\u003cbr\u003eA: Rack alignment, grounding continuity, and balanced module seating pressure are necessary to prevent connector deformation and intermittent backplane contact.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eSite Mounting Notes\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInstall the chassis within a grounded 19 in control cabinet using vibration-stable rack hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain unobstructed airflow around installed power modules and monitor assemblies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeparate AC input cabling from low-level signal wiring to reduce conducted electrical noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify terminal torque values according to plant electrical standards before energizing the chassis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspect backplane connectors for bent pins or contamination before module insertion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse anti-static handling procedures during installation and maintenance operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm cabinet protective earth continuity prior to applying AC power input.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIncluded Supply Scope\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIPCHS01 Power Module Chassis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTerminal connection hardware\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFactory-installed bus bar assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtective anti-static packaging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOptional items may include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMPS II power modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower monitor modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRack mounting accessories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eABB Infi 90 interface assemblies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistics and Packing Information\u003c\/h3\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish. Shipment available through DHL, FedEx, or UPS depending on destination routing requirements.\u003c\/p\u003e\n\u003cp\u003eIndustrial anti-static packaging is applied for export handling. Internal cushioning and reinforced carton protection are used for rack-mounted power distribution assemblies during international transport.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021118165165,"sku":"IPCHS01","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/IPCHS01-3.jpg?v=1779955271","url":"https:\/\/www.maxwellplc.com\/products\/abb-ipchs01-mps-ii-power-module-chassis-infi-90","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}