{"product_id":"abb-ior-810-s800-i-o-gateway-module","title":"ABB IOR-810 S800 I\/O Gateway Module","description":"\u003cp\u003eConfigured for protocol translation and data routing between upper-level HNET bus structures and local field units in S800 I\/O architecture, the \u003cb\u003eABB IOR-810\u003c\/b\u003e (\u003cb\u003eIOR-810\u003c\/b\u003e Gateway Module) provides direct physical\/electrical execution. It translates analog 4-20 mA and 0-10 V signals across galvanic isolation barriers while maintaining status indication through front-panel LEDs.\u003c\/p\u003e\n\u003ch3\u003eDesignation \u0026amp; Model Architecture\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eIOR\u003c\/b\u003e: Interface and Optical Gateway Module functional designation within the control node network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003e810\u003c\/b\u003e: S800 system interface hardware platform variant engineered for HNET master communications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eP-HB-IOR-80010000\u003c\/b\u003e: Dedicated spare part order identifier for field replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \u0026amp; Environmental Attributes\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIOR-810\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSWEDEN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.1 x 10.2 x 12.7 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3-8 W typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSupply Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIsolation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 VAC channel-to-channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Types\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4-20 mA, 0-10 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHumidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5-95% RH non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpare Part Model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eP-HB-IOR-80010000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDiagnostic Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 Status LEDs, Front Stop\/Reset Pin\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTariff Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePlace of Shipment\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eXiamen, China\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eNetwork Communication \u0026amp; Deterministic Processing\u003c\/h3\u003e\n\u003cp\u003eThe gateway module manages internal backplane bus communication velocity to optimize cyclic telemetry exchange between distributed I\/O clusters and supervisory control stations. Compatible with high-density I\/O density scaling requirements, the hardware maintains deterministic field updates without network traffic congestion. Firmware flash compatibility ensures seamless system software synchronization across Ethernet and fieldbus networks during system expansions.\u003c\/p\u003e\n\u003ch3\u003eUnit Supply Packaging\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e1 x ABB IOR-810 gateway module unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Hardware installation reference sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation \u0026amp; Cabling Protocol\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSnap the module securely onto the designated DIN rail segment or terminal base unit until the mechanical latch engages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnect the 24 VDC external power feed with proper polarity, maintaining continuous earth conductor connections to the panel frame.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeparate 4-20 mA and 0-10 V analog field cabling from high-voltage AC power wiring to prevent inductive signal interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse the front stop\/reset pin to clear latching communication fault flags during routine maintenance commissioning routines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Hardware Reference FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the primary function of the front stop\/reset pin on the module?\u003c\/p\u003e\n\u003cp\u003eThe front stop\/reset pin allows manual clearing of hardware fault codes and forces a local communication stack restart.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat supply voltage level is required to power the gateway module?\u003c\/p\u003e\n\u003cp\u003eThe module operates on a standard nominal supply input of 24 VDC with a typical power draw between 3 W and 8 W.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat level of electrical isolation is provided across channel signal paths?\u003c\/p\u003e\n\u003cp\u003eThe internal galvanic barriers withstand up to 1500 VAC continuous continuous isolation channel-to-channel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhich analog field signal formats are natively processed by the hardware?\u003c\/p\u003e\n\u003cp\u003eThe unit natively handles standard process instrumentation signals including 4-20 mA current and 0-10 V voltage loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat status feedback do the 6 front LEDs provide to the operator?\u003c\/p\u003e\n\u003cp\u003eThe 6 LEDs report power health, module fault condition, HNET communication status, and local bus transfer activity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the module operate in extreme ambient temperature conditions?\u003c\/p\u003e\n\u003cp\u003eYes, the hardware is rated for continuous field execution in ambient temperatures ranging from -25 to +70 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the spare part catalog number assigned to this gateway module?\u003c\/p\u003e\n\u003cp\u003eThe manufacturer designated spare part model reference number for this exact unit is P-HB-IOR-80010000.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should signal cable shielding be handled during installation?\u003c\/p\u003e\n\u003cp\u003eShield wires from 4-20 mA loops must be grounded at a single earth point on the cabinet bar to avoid ground loop currents.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021109350573,"sku":"IOR810","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb_ior810_1.jpg?v=1787241816","url":"https:\/\/www.maxwellplc.com\/products\/abb-ior-810-s800-i-o-gateway-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}