{"product_id":"abb-inipt02-plant-loop-remote-transfer-module-bailey-infi-90","title":"ABB INIPT02 Plant Loop Remote Transfer Module Bailey INFI 90","description":"\u003cp\u003eConfigured for signal transfer between INFI-NET and Plant Loop control domains in Bailey INFI 90 architectures, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB INIPT02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eINIPT02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePlant Loop Remote Transfer Module) provides deterministic electrical and communication interface execution for distributed control loop integration across multi-level DCS networks. The module operates with 24 V DC supply input and supports remote loop transfer over distances up to 1000 m with controlled signal integrity handling.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eINIPT02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e17.8 x 5.1 x 33.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e10-18 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Transfer Distance\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eINFI-NET to Plant Loop signal transfer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eINFI-NET \/ Plant Loop Transfer Architecture Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe INIPT02 implements protocol-level and signal-level bridging between INFI-NET backbone communication and Plant Loop field control segments. Within ABB Bailey INFI 90 systems, the transfer module supports deterministic loop synchronization where timing alignment between supervisory commands and loop execution is maintained through controlled buffering and signal conditioning. Electrical isolation is applied between network-side logic and loop-side execution stages to reduce cross-domain noise propagation in long-distance cabinet-to-cabinet installations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does INIPT02 support hot-swap installation?\u003cbr\u003eA: The module is typically installed in a powered-down rack segment. Hot-swap depends on system backplane configuration and rack design constraints.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum communication distance supported?\u003cbr\u003eA: The transfer path supports up to 1000 m under defined Plant Loop configuration and cable specification limits.\u003c\/p\u003e\n\u003cp\u003eQ: What is the power loading requirement on the backplane?\u003cbr\u003eA: Typical consumption is 10-18 W at 24 V DC, depending on operational load and communication activity.\u003c\/p\u003e\n\u003cp\u003eQ: Is galvanic isolation implemented between INFI-NET and Plant Loop sides?\u003cbr\u003eA: Isolation is implemented between communication domains to reduce ground loop coupling and signal interference.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eThe INIPT02 module shall be mounted in a standard ABB Bailey INFI 90 cabinet slot with proper mechanical locking. Seating must ensure full connector engagement without partial insertion to avoid backplane signal discontinuity. Shielded twisted pair cabling is required for plant loop signal routing, with shield termination performed at a single grounding reference point. Cable routing shall maintain separation from high voltage conductors to minimize induced noise. Verify 24 V DC supply stability before energizing the module.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eABB INIPT02 Plant Loop Remote Transfer Module unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard factory identification label and configuration baseline\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eINFI 90 rack-compatible mounting interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAnti-static industrial packaging for transport protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem documentation set (if supplied with batch)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDelivery Information\u003c\/h3\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish, shipped via DHL \/ FEDEX \/ UPS. Anti-static industrial packaging with shock-resistant foam and moisture barrier protection for industrial transit conditions.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021108007085,"sku":"INIPT02","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/INIPT02-1.jpg?v=1779953152","url":"https:\/\/www.maxwellplc.com\/products\/abb-inipt02-plant-loop-remote-transfer-module-bailey-infi-90","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}