{"product_id":"abb-inict03a-infi-net-to-computer-transfer-module-infi-90","title":"ABB INICT03A Infi-Net to Computer Transfer Module Infi 90","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB INICT03A\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eINICT03A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInfi-Net to Computer Transfer Module, serves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eINICT03A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTransfer Module utilized to execute high-bandwidth asynchronous and synchronous bidirectional protocol translation across Infi 90 platforms.\u003c\/p\u003e\n\u003ch3\u003ePhysical and Electrical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eINICT03A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.54 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.7 x 31.7 x 17.8 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eROM Memory Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e512 kbytes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRAM Memory Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Mbytes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage Required\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+5 VDC (operating tolerance ±5%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.8 W typical (10 W maximum)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.958 A typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSerial Communication Rates\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 to 19,200 baud (user-selectable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eParallel Communication Rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Mbytes\/sec via dedicated SCSI port\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModule Mounting Profile\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOccupies exactly one slot in standard INFI 90 module mounting unit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRelative Humidity Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% RH (non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTariff Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module integrates directly into the INFI 90 cabinet backplane, matching internal backplane bus communication velocity constraints to prevent processing bottlenecks during multi-node broadcast storms. Onboard execution logic relies on a designated firmware flash compatibility matrix to synchronize data packets between the 512 kbytes ROM block and the host computer operating system environment.\u003c\/p\u003e\n\u003cp\u003eThe 2 Mbytes RAM array buffers transient real-time process data, enabling uninhibited throughput configuration shifts without disturbing concurrent I\/O density scaling routines across parallel controller slots. The embedded system hardware monitors transmission parity and frame alignment errors, processing local protocol translations directly inside the network layer before presenting the output vector to the host bus interface.\u003c\/p\u003e\n\u003ch3\u003eTechnical Performance Queries\u003c\/h3\u003e\n\u003cp\u003eQ: What is the procedure for altering the serial interface baud rate on the module?\u003c\/p\u003e\n\u003cp\u003eA: Adjustments must be performed prior to installation by setting the physical dual-inline package (DIP) switch configurations located on the primary circuit board to match the desired baud value from 50 to 19,200 baud.\u003c\/p\u003e\n\u003cp\u003eQ: How does the SCSI port interface function under continuous communication scenarios?\u003c\/p\u003e\n\u003cp\u003eA: The SCSI port functions as a high-speed parallel interface running at 4 Mbytes\/sec, utilizing direct memory access (DMA) transfers to move data blocks from the module 2 Mbytes RAM directly to the host application memory buffer without overloading the central processing unit.\u003c\/p\u003e\n\u003cp\u003eQ: Can the module withstand continuous operation at elevated temperatures without thermal throttling?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the hardware components are rated for continuous industrial execution across a standard thermal profile of -40 to +70 deg C, assuming the module mounting unit fan assemblies deliver unhindered forced-air vertical cooling vector paths.\u003c\/p\u003e\n\u003cp\u003eQ: Is hot-swapping supported for the module during active system monitoring?\u003c\/p\u003e\n\u003cp\u003eA: No, live removal or insertion of the module while the backplane is energized creates inductive voltage spikes that risk damaging the onboard CMOS memory chips and terminating active data streams on the serial or parallel link.\u003c\/p\u003e\n\u003ch3\u003eField Insertion and Earthing Protocols\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCompletely isolate the power source feeding the specific INFI 90 module mounting unit compartment before attempting module insertion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlign the upper and lower circuit board edges with the molded plastic track guides of the chassis frame to ensure parallel entry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSmoothly press the card slide lock mechanism home until the rear connectors mate securely with the backplane pin distribution block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify that the integrated metal grounding clip achieves clean, unpainted surface contact with the system enclosure sub-rack frame to ground static accumulation paths.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFasten front panel captive retention screws to a torque specification of 0.45 Nm to minimize vibration-induced connection failure risk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackage Component Checklist\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne fully assembled INICT03A transfer module unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePre-configured onboard jumper configuration headers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFactory electrical performance verification datasheet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistical Dispatch Profiles\u003c\/h3\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish, utilizing international expedited shipping networks via DHL, FEDEX, or UPS. The module is enclosed inside moisture-impermeable, anti-static industrial packaging assemblies lined with precise physical shock-mitigation foam layers to safeguard micro-component integrity during transit.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021156274349,"sku":"INICT03A","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/INICT03A_1.jpg?v=1779776914","url":"https:\/\/www.maxwellplc.com\/products\/abb-inict03a-infi-net-to-computer-transfer-module-infi-90","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}